Explain following techniques related to energy conservation in transmission and distribution system. (i) By balancing phase currents (ii) Variable technical losses (I2R losses).

1 Answer

Answer :

(i) Balancing Phase currents: Proper (healthy balanced) three phase loads always draw equal currents in all lines but single phase loads in the 3 phase 4 wire system or loads connected between two phase lines lead to unequal currents in the lines. This leads to circulating currents in transformers/ neutral conductors due to which losses increase. Hence balancing of such feeder currents is needed to reduce the feeder copper losses. As a result of unequal loads on individual lines, sequence components in them cause overheating of transformers, cables, conductors, motors. These increase losses and resulting in motor malfunctioning under unbalanced voltage conditions.  Due to unequal loading on the single phase lines of a 3 phase, 4 wire supply system the voltage drops in lines are different that create unequal (non-rated) phase and line voltages at the load leading to unhealthy effects on the loads. Large ovens/furnaces of the single phase and two phase types are such loads. Hence it becomes necessary to equate/balance the three phase/line currents at the supply terminals. For furnaces the Scott connection transformers are employed to derive the two phase supply from the three phases which transforms the two phase load equally over the three phases. Unequal loading is also created due to unequal lengths of feeders of the three phases. Hence it is necessary to obtain current balance to the maximum.


(ii) Variable technical losses (I2R losses) 

Techniques of Reducing Technical Losses: 1) Find out the weakest area of more technical loss in the distribution system. 2) Locate distribution transformer near to the load centre. 3) Use proper capacity distribution transformer. 4) Use energy efficient transformers. 5) Use shunt capacitors for reactive power management. 6) Use HVDC system for long distance bulk power transmission. 7) Use ACSR or bundled conductors instead of solid conductors. 8) Reduce overloads on distribution transformer. 9) Use reactive power compensation techniques. 10) Use power factor controlling devices or techniques. 11) Minimize I2R losses. 12) Balance the load currents. 13) Regulate the system voltages.

Related questions

Description : Explain the “mitigation of power theft” and “faulty meter replacement” for energy conservation techniques to reduce commercial losses. 

Last Answer : Energy conservation techniques to reduce commercial losses:  1. Mitigation of Power Theft: Power theft being the most important issue which all of the service providing utilities ... agricultural sector. Prepaid meters may prove effective measures against unauthorized abstraction of energy. 

Description : State the losses in secondary distribution system. 

Last Answer : The losses in secondary distribution system: a) Technical losses: 1. Due to poor voltage 2. Due to unbalance load 3. Due poor quality of transformer & its components 4. Due to poor quality ... of induction type of energy meter. 3. Lack of administration. 4. Energy theft 5. Unmetered supply

Description : Describe the following energy conservation methods of lighting system. i) By replacing lamp sources ii) Using light control gears.

Last Answer : Energy conservation methods of lighting system:  i) By replacing lamp sources:  Installation of energy efficient fluorescent lamps in place of Conventional fluorescent lamps. Installation of ... (HF) electronic ballasts in place of conventional ballasts which saves energy up to 35%.

Description : The permissible voltage variation in transmission and distribution system is:  (A) ± 0.1% (B) ± 1% (C) ±10% (D) ± 25%

Last Answer : The permissible voltage variation in transmission and distribution system is: ±10%

Description : Explain any two energy conservation techniques in fan.

Last Answer : Following are energy conservation techniques in Fans : 1) Use the electronic regulators instead of conventional regulator: Function of regulator is to control the speed of the fan. The conventional regulators ... 't forget to properly maintain your electric fan and keep it in good working order. 

Last Answer : In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

Description : Describe the following energy conservation methods of electrical motor. i) By motor survey ii) By matching loads with motor rating

Last Answer : Energy conservation methods of electrical motor:  1) By Motor Survey: Large industries have a massive population of LT motors. Load survey of LT motors can be taken-up methodically to ... -speed motors, eddy-current couplings, fluid couplings, and solid-state electronic variable speed drives.

Description : Explain energy conservation method in lighting system by using installation of separate transformer / servo stabilizer.

Last Answer : Energy conservation techniques by installation of separate transformer / servo stabilizer: The luminous efficiency of lamps depends upon the voltage applied across the terminals. It gives its best ... the voltage constant in that installation for giving best luminous efficiency of lamps.

Description : Explain the need of energy conservation in present scenario.

Last Answer : Need of energy conservation in present scenario: 1. Fossil fuels like coal, oil which have taken no. of years to form and now they are on the verge of depleting soon. 2. In last ... protection and integrated economic and social development. 9. Energy saved is as good as energy generated. 

Last Answer : Energy conservation technique in induction motor by minimizing idle and redundant running of motor: 1) Loss of energy as the no load power drawn is approximately about 12% to 16% of rated ... to unnecessary line losses. 4) Reduction in overall system energy efficiency over period of time.

Description : Explain energy conservation technique “by improving power quality” for induction motor.

Last Answer : Energy conservation method in induction motor by improving power quality: Electrical energy can be conserved by improving the power quality. It can be achieved by avoiding voltage unbalance, maintaining ... losses can be minimized by using harmonic filter thus reducing the harmonics in the system.

Description : Explain the following energy conservation techniques: (i) By reducing I2R losses in Trans. system (ii) By optimizing distribution voltage.

Last Answer : i) By reducing I2R losses in Trans:  1. Opting for low resistance All Aluminum Alloy conductors (AAAC) in place of conventional aluminum cored steel reinforced (ACSR) lines. 2. ... line power losses. Thus maintaining the voltages at the specified levels leads to energy savings/conservation.

Description : State the difference between energy conservation and energy audit. 

Last Answer : energy conservation Energy audit It is reducing the growth of energy consumption by avoiding unnecessary usage of energy It is an inspection, survey & analysis of energy flows ... Various measuring instruments, with proper sensing elements are required for the energy audit. 

Description : List the energy conservation technique in induction motor. 

Last Answer : Following are the list of energy conservation techniques in electrical motors: 1) Reduction in iron losses by using low loss silicon steel core material laminated to thinner dimension. 2) Using bigger length ... at light load. 13) By rewinding in induction motor 14) By motor survey

Description : Define Energy conservation. 

Last Answer : Energy conservation:  Reduction in the amount of energy consumed in a process or system, or by an organization or society, through economy, elimination of waste, and rational use is referred ... electrical power and to increase the efficiency of every machine and material by minimizing the losses.

Description : Discuss how power factor tariff results into energy conservation.

Last Answer : Power factor tariff results into energy conservation: i) Applying incentives and penalties according to power factor is an effective way, which enables consumer to improve power factor so that he can ... finally leads to reduction in the current drawn by the load and helps for energy conservation.

Description : What is Time of Day tariff? How it help in energy conservation?

Last Answer : Time-off-day tariff:- In addition to basic tariff (Maximum Demand Tariff / KVA Maximum Demand Tariff / Load factor tariff /also the tariff in which P.F. of industrial consumer is taken ... the rated load for longer times of the day their overall efficiency gets higher helping to conserve energy.

Description : State the need of energy conservation in transformer. 

Last Answer : Need of energy conservation in transformer: In electrical power system, transformers are used to change the voltage levels of different sections as per the need of economic and efficient operation of ... for some other good reason. Therefore, there is need of energy conservation in transformer.

Description : State the need of energy conservation in electrical motor.

Last Answer : Need of energy conservation in Electrical motors: 1. Induction motors are used as electrical drives in industrial, commercial and residential sectors. 2. Considering all industrial applications, 70% of ... system. 8. To adopt advanced technology in design and to use better quality materials.

Description : TRANSMISSION AND DISTRIBUTION MCQ

Last Answer : 51. It is difficult to maintain oil filled cables. (a) Yes (b) No Ans: a 51. In capacitance grading a homogeneous dielectric is used. (a) Yes (b) No Ans: b 52. In congested areas where excavation is ... The metallic sheath may be made of lead or lead alloy or of aluminium. (a) Yes (b) No Ans: b

Description : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Last Answer : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Description : Explain about Electric Energy Conservation? How Energy conservation can be done in Lighting?

Last Answer : Ans: Today in India, the per capita availability of energy is much less than the energy in developed countries. The demand for energy is always out placing availability, the shortfall being ... In streets of rural areas and side streets, street lighting luminaires with fluorescent lamps are used.

Description : Grid distribution system

Last Answer : Grid distribution system:-  In this system, when the feeder or loop or ring is charged (energized) by two or more than two substations from two or more than two different generating stations then it is known as “Grid distribution system. In this system only one feeder is utilized at a time. 

Description : Define: primary and secondary distribution system 

Last Answer : i) Primary Distribution:  It is a 3-phase, 3-wire transmission line connected in between receiving substation to Distribution substation. OR It is link between receiving substation & ... substation to consumer line. OR It is link between distribution transformer substation & consumer. 

Description : requirements of a distribution system

Last Answer : Following requirements of a distribution system.  1. Layout should be simple in design. 2. It should have less initial cost 3. The distribution system should have minimum distribution ... stability of existing distribution system. 15. Time required for completion of work should be less. 

Description : Why radial distribution system used for short distance ? 

Last Answer : Because of following disadvantages radial distribution system is not used for long distance:  Since there is only one feeder to DTC feed at one point so, 1) There is no reliability ... more time for fault finding & repairing Hence radial distribution system is used for short distance.

Description : The main criterion for selection of the size of a radial distribution system is

Last Answer : The main criterion for selection of the size of a radial distribution system is voltage drop

Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Description : What do you mean by energy conservation? why it is required and how it can be done?

Last Answer : Ans Energy conservation means saving of Electricity without fore going its utility. Conservation is required in present scenario of growing demand of power, depleting of natural resources and increase of and lack of ... pumps. i. Use of APFC panels j. Use of copper wiring inplace of Aluminum wiring.

Description : State the Principle of energy conservation.

Last Answer : Principle of energy conservation: The law of conservation of energy states that the total energy of an isolated system remains constant-it is said to be conserved over time. Energy can neither be ... due to burning of fuels, greenhouse gases and avoid harmful effects on all livings on earth. 

Description : Explain with schematic diagram direct distribution of solar energy.

Last Answer : Explain with schematic diagram direct distribution of solar energy: Solar energy reaching earth's surface consists of two components: i) Direct solar energy, ii) Diffused solar energy. Direct solar energy ... radiation. It is very intense radiation and it can produce sun burns and shadows.

Last Answer : Reactance relay is preferred for phase fault on short transmission line.

Description : With reference to execution of work explain the following: i) Administrative approval ii) Technical sanctions 

Last Answer : Administrative approval:  When any government department requires executing a project like network addition or extension work or installation of new project. It requires necessary administrative approval ... designated by government. The sanction given by authority is called technical sanction

Description : Phase margin is the amount of angle to make the system  (1) Oscillatory (2) Stable (3) Unstable (4) Exponential

Last Answer : Phase margin is the amount of angle to make the system Unstable 

Description : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

Last Answer : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is 22.0 mm

Description : When a V-V three phase transformer system is converted into a Δ-Δ system, increase in capacity of the system is (A) 86.6% (B) 50% (C) 57.7% (D) 73.2%

Last Answer : When a V-V three phase transformer system is converted into a Δ-Δ system, increase in capacity of the system is 73.2%

Description : write short notes on single phase system.

Last Answer : A "phase" in an electrical system is often referred to as the waveform (may be voltage or the current) of the power supply. The waveform in an AC system is typically ... domestic household or commercial supplies and street lighting. Industrial supplies requires three phase electrical supply .

Description : In voltage source converter based HVDC transmission system the active power is controlled by changing (A) phase angle of the converter ac input voltage (B) supply frequency of the converter ac input voltage (C) magnitude of the converter ac input voltage (D) DC voltage at the inverter terminals

Last Answer : In voltage source converter based HVDC transmission system the active power is controlled by changing phase angle of the converter ac input voltage

Description : If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

Last Answer : If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

Last Answer : Ungrounded neutral transmission system is not recommended because of system insulation being overstressed due to over voltages, insulation overstress may lead to failure and subsequent phase to phase faults, being inadequately protected against ground fault.

Description : The transient currents are associated with the?

Last Answer : The transient currents are associated with the changes in the stored energy in the inductors and capacitors.

Last Answer : For handling greater currents induction wattmeters are used in conjunction with current transformers.

Description : Eddy currents are induced in the pole shoes of a D.C. machine due to?

Last Answer : Eddy currents are induced in the pole shoes of a D.C. machine due to relative rotation between field and armature.

Last Answer : Interruption of large currents by relay requires arc suppressing blow out coils, wide separation of the opened contacts, high speed opening of contacts.

Description : State the meaning of creeping error in 1 phase energy meter.

Last Answer : Creeping error: It is defined as the slow and continuous rotation of the disc of the energy-meter when only pressure coil is energized with no current in the current coil (load current = 0). ... magnet on this iron wire is sufficient to prevent continues rotation of the disc on no load condition.

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Last Answer : Induction type single phase energy meters measure electric energy in kWh.

Description : Explain how technical losses can be reduced by use of energy efficient transformer in Transmission and Distribution system.

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : Do you know become a creative and technical?

Last Answer : Getting a good education is a great way to start!!!

Description : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above