Wye Delta Transformation

1 Answer

Answer :

Wye Delta Transformation 1 : https://youtu.be/mPKeczDWZCo

Wye Delta Transformation 2 : https://youtu.be/k80VbHI-wwg

Wye Delta Transformation 3 : https://youtu.be/6cnwj15uw5M

Wye Delta Transformation 4 : https://youtu.be/g0w4Fs09Do4

Wye Delta Transformation 5 : https://youtu.be/GY7L_ixeXPE

Wye Delta Transformation 6 : https://youtu.be/tFSaIwEhhpg

Wye Delta Transformation 7 : https://youtu.be/Hf5X6Itt1Hw

Wye Delta Transformation 8 : https://youtu.be/knRb5UW1404

Wye Delta Transformation 9 : https://youtu.be/JBwHKBJ08WM

Related questions

Description : Wye and delta conversion formula

Last Answer : Wye and delta conversion formula

Description : Wye (Star) to Delta Conversion

Last Answer : Wye (Star) to Delta Conversion

Description : Delta to Wye Conversion

Last Answer : Delta to Wye Conversion

Description : Source transformation Replace the circuit with voltage source in series with a single resistor

Last Answer : Source transformation Replace the circuit with voltage source in series with a single resistor

Description : Define: 1) voltage ratio, 2) current ratio, 3) transformation ratio of transformer.

Last Answer : 1) Voltage ratio: The voltages in primary and secondary winding is proportional to number of turns in primary and secondary respectively. So, the voltage ratio is same as transformation ratio. V2/V1 = N2 ... as transformation ratio of transformer. It is denoted by K. K = N2/N1

Description : What is transformation ratio?

Last Answer : Transformation Ratio (k):- It is the ratio of secondary number of turns to primary number of turns. OR It is the ratio of secondary voltage to primary voltage. OR It is the ratio of primary current to secondary current. 

Description : The voltage transformation ratio of a transformer is equal to the ratio of?

Last Answer : The voltage transformation ratio of a transformer is equal to the ratio of secondary induced e.m.f. to primary induced e.m.f.

Description : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is?

Last Answer : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is approximately equal to 1.

Description : Use of auto-transformer is economical when the transformation ratio is?

Last Answer : Use of auto-transformer is economical when the transformation ratio is near unity.

Description : Does Delta have something that I can plug my computer in to for power?

Last Answer : Older planes have to be retrofitted to have a power source by every seat. It is pretty standard on newer planes. Without knowing the the type of plane it would be impossible to know. And even with that it might be hard to say for certain. Your best bet is to call and ask.

Description : Delta to Star Conversion Example

Last Answer : Delta to Star Conversion Example

Description : Star to delta conversion examples

Last Answer : Star to delta conversion example 1

Description : Compare star and Delta Connection.

Last Answer : Compare Star and Delta connected system:  Star connected system Delta connected system   In STAR connection, the starting or finishing ends (Similar ends) of three coils are connected together to form the ... VPH Line Current is √3 times of Phase Current. i.e. IL = √3 IPH

Description : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side

Last Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Description : The line current in a balanced delta system is 30 A. The load current is (A) 30√3 A (B) 30/√3 A (C) 10 A (D) 30/√2 A

Last Answer : The line current in a balanced delta system is 30 A. The load current is 30/√3 A

Description : Explain Three Phase Bidirectional Delta Connected Controller.

Last Answer : Three Phase Bidirectional Delta Connected Controller:

Description : What is difference between Star and Delta Connection?

Last Answer : Star is        1. Open ckt       2. At center point present  neutral   Delta is     1.   Closed ckt 2.      Neutral not present in this case 

Description : Has any jelly here gone through est training?

Last Answer : answer:I have an older female relative who was very into this for a while. I was too young to really remember, but this relative took my mom to a retreat and mom said it was very reminiscent of an Amway ... to help control their lives. I do not think, as a whole, it has stood the test of time.

Description : Find power delivered by voltage source

Last Answer : Find power delivered by voltage source

Description : If a loved one that doesn’t live with you refuses to get a vaccine, do you avoid them?

Last Answer : I would tell my brother I’m concerned and suggest getting an antibody test. It’s not an extremely accurate way of evaluating immunity, but if his number is zero, he might think twice about interacting with the grandkids. If his number is very high, it might help you feel better.

Description : The electrical schematic illustrated in figure A, depicts a/an _____________. EL-0059 A. autotransformer B. Delta Wye transformer C. primary EMF generator D. potential transformer

Last Answer : Answer: D

Description : One important difference between wye-connected and delta-connected generators is that delta connections have ____________. A. line voltages equal to the vector sum of the phase voltages B. phase voltages 90° ... C. line current equal to the phase current D. line voltage equal to the phase voltage

Last Answer : Answer: D

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase delta-wye arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: C

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase wye-delta arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: D

Description : Derive an expression for delta to star transformation. 

Last Answer : For delta network the resistance between the terminals 1 and 2 consists of R12 in parallel with  (R23+R31) Hence ,the resistance between the terminals 1 and 2 is In case of star network the ... equation( ii) from( i),we get Adding equations (iii) and( iv),we have 

Description : How do connect a wye connection for 12 leads out motor?

Last Answer : Normally there are six terminals (two terminals per winding in 3phase system) for a motor. If you find 12 terminals, you need toread the motor name details or specifications to get more info. Themotor could be with two different sets of winding (double speedmotor)

Description : How do you wire a star wye motor?

Last Answer : This is better explained through a wiring diagram. AC 3 phasemotor has three windings. Each winding has two terminals. Lets usdenote each winding as follows. Winding 1 - A1 and A2, Winding 2 -B1 ... to refer to motor name plate, its wiring diagram. You needto also check the direction of rotation.

Description : Which of the following statements about a three-phase wye connection is correct? A. The line current is 1.73 times the phase current. B. The phase current is 1.73 times the line current. C. The line voltage is 1.73 times the phase voltage. D. The phase voltage is 1.73 times the line voltage.

Last Answer : Answer: C

Description : If you obtain a low resistance reading with a megohmmeter connected between terminals 'A' and 'C' of the three-phase, wye-connected winding shown in the illustration, there is __________. EL-0074 A. no open circuit ... 'B' C. an open circuit between 'A' and 'C' D. an open circuit in both windings

Last Answer : Answer: A

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase wye-wye arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: B

Description : Where WYE body globe valve is used?

Last Answer : Answer: In line ports with stem emerging at 45 degree, for erosive fluids due to smoother flow pattern.

Description : (a) Define permeability. (b) Define MMF. (c) Define form factor of an alternating quantity. (d) Define frequency and time period of an alternating quality. (e) Define transformation ratio of transformer. ... and state the meaning of each term used. (g) Give two applications of single phase motors. 

Last Answer : Permeability : It is the ability of a magnetic/Non magnetic material to allow setting up of flux in it.  MMF : The magneto motive force (MMF) is the force required to setup flux in a magnetic / ... applications of single phase motors : Water pumps, ceiling fan, lathe machine

Description : Design of IIR filter using Bilinear transformation 2

Last Answer : Design of IIR filter using Bilinear transformation 2  

Description : 3kW load is supplied by an autotransformer with 0.7 transformation ratio. Conductively transferred power from primary to secondary is (A) 2.1 kW (B) 0.9 kW (C) 4.29 kW (D) 3 kW

Last Answer : 3kW load is supplied by an autotransformer with 0.7 transformation ratio. Conductively transferred power from primary to secondary is 2.1 kW

Description : Calculate the equivalent resistance between A & B using star-delta conversion

Last Answer : Solution :  Converting Inner star in to delta-  Resistances 4 and 6 are in parallel in all branch so

Description : for Delta-Star connection of 3-phase transformer: i) Draw the connection diagram ii) List any two advantages of this connection iii) State its area of application. 

Last Answer : Disadvantages: i) In this type of connection, the secondary voltage is not in phase with the primary. Hence it is not possible to operate this connection in parallel with star-star or delta-delta ... iv) As line current is equal to phase current the conductor size of winding should be large. 

Last Answer : Advantages of open delta connection of 3-phase transformer:  1. When one of the phase in case of delta-delta bank is out of order by any reason, the service will be continued till ... demand in future (about 33%) will be supplied by converting open delta connection to delta-delta connection.

Description : Describe the power and control circuit for automatic Star-Delta starter for 3-phase induction motor.

Last Answer : Power circuit: Control circuit: 

Description : The main application of delta/zig-zag connected 3-phase transformer is to supply (A) balanced loads (B) unbalanced loads (C) furnace loads (D) single-phase loads

Last Answer : The main application of delta/zig-zag connected 3-phase transformer is to supply unbalanced loads

Description : Consider the following statements regarding three-phase transformers in Open -Delta (V -V) connections :  1. Being a temporary remedy when one transformer forms of Delta -Delta system is &imaged, and removed from service.  ... and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Last Answer : Consider the following statements regarding three-phase transformers in Open -Delta (V -V) connections :  1. Being a temporary remedy when one transformer forms of Delta -Delta system is &imaged, and removed from service.  ... and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Description : Three equal impedances are first connected in delta across a 3 -phase balanced supply. If the same impedances are connected in star across the same supply then,

Last Answer : A

Description : Three resistances of 3 Ω each are connected in delta. The value of the resistances in the equivalent star is : (A) 27 (B) 9 (C) 1.5 (D) 1 Ω

Last Answer : 9