Explain over-current protection of transformer.

1 Answer

Answer :

Over-Current Protection of Transformer:

image

Simple over-current & earth fault protection of transformer against external shortcircuit and excessive overloads is shown in the above figure. The over-current and earth fault relays may be of inverse and definite minimum time type or definite time relays. The over-current relay has three elements; one for each phase winding. The normal range of current setting available on IDMT over-current relay is 50% to 200%. Due to excessive overload or any external fault, when over-current flows through the transformer winding, the corresponding phase CT supply the current to over-current relay. The relay depending upon its setting, sends trip command to the circuit breaker and the transformer is disconnected from load or fault.

Related questions

Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Description : List two limitations of Differential-Protection scheme for transformer.

Last Answer : Limitations of Differential Protection Scheme of Transformer:  1) Due to the magnetization characteristics of the CTs used, the ratio errors change with respect to the circulating currents.  2) ... & improper operation.  5) Inrush of magnetizing current may lead to inadvertent operation.

Description : Write down limitation of differential protection of transformer.

Last Answer : Limitations of differential protection of transformer: 1) Due to the magnetization characteristics of the CTs used, the ratio errors change with respect to the circulating currents. 2) The pilot wires ... current (higher imbalance) due to which accuracy of sensing & operation is decreased. 

Last Answer : Over voltage protection is recommended for hydro-electric generators, steam turbine generators, gas turbine generators.

Description : The burden of protective Current Transformer (CT) is specified in

Last Answer : The burden of protective Current Transformer (CT) is specified in Volt - Ampere

Description : The operating point of a protective current transformer is near the

Last Answer : The operating point of a protective current transformer is near the Ankle point

Description : The inrush current of a transformer at no load is maximum if the supply voltage is switched on  (1) at peak voltage value (2) at zero voltage value (3) at half voltage value (4) at 0.866 time voltage value

Last Answer : At 0.866 time voltage value

Description : Explain the “Differential Protection Scheme” used for alternators with neat labeled diagram.

Last Answer : Differential Protection Scheme for Alternator: Figure shows the differential protection provided to 3 phase alternator. Here identical CTs are placed on both sides of 3 phase alternator and ... causing its operation. Relay sends trip signal to the CB, thereby alternator circuit is tripped.

Description : Explain with neat sketch, the Pilot wire protection scheme applied to transmission line.

Last Answer : Pilot Wire Protection scheme of Transmission Line : Figure shows the single line diagram of Merz price voltage balance system for pilot wire protection of three phase transmission line. ... through the relay, which gives trip signal to the circuit breaker for protection of transmission line.

Description : Explain differential protection scheme for busbars with neat sketch.

Last Answer : Differential Protection Scheme for Bus bar:  Under normal conditions, the sum of the currents entering the bus bar zone is equal to those leaving it and no current flows through the relay ... of these currents will flow through the relay coil causing opening of circuit breaker of bus-bar.

Description : Explain differential protection of busbar.

Last Answer : Differential protection Scheme for bus bar: Under normal conditions the sum of the currents entering the bus bar zone is equal to those leaving it and no current flows through the relay ... . The difference of these currents will flow through the relay coil causing opening of circuit breaker.

Description : Explain negative phase sequence protection of alternator.

Last Answer : Negative phase sequence protection of alternator: Unbalanced loading on alternator mainly causes the negative sequence currents which generate the negative sequence components of magnetic fields. These fields ... components due to unbalance and operates the relay which further operates CB.

Description : Explain fault bus protection scheme.

Last Answer : Fault bus protection of busbar: In this scheme, the substation is so designed that every fault on the bus bar is converted to earth fault. Under normal operating conditions, there is no current flowing ... This results in operation of relay to actuate trip coil of CB to trip the circuit.

Description : Explain distance protection of transmission line with neat sketch diagram.

Last Answer : Distance protection of Transmission line: Distance protection scheme uses impedance relay. The relay operation is based on the impedance (or distance) between the relay and point of fault. Figure shows ... than ZL and impedance relay operates which operates the CB and line is protected.

Description : The inverse definite mean time relays are used for over current and earth fault protection of transformer against (a) heavy loads (b) internal short-circuits (c) external short-circuits (d) all of the above

Last Answer : (b) internal short-circuits

Description : Discuss in brief the principle of distance protection and state four advantages of distance protection scheme.

Last Answer : Advantages: 1. System is economical 2. High speed of interruption 3. Suitable for very long and high voltage transmission lines. 4. No problem of pilot wires.

Description : State two requirements of transmission line protection. 

Last Answer : Requirements of Transmission Line Protection: 1) Faults on lines should be quickly detected to initiate actions to maintain system stability. 2) For very long lines the protection system must be capable ... backup protection in the event of failure of circuit breaker (nearest to fault) to operate.

Description : How can we use CT and PT for protection purpose?

Last Answer : CT and PT for Protection purpose: Current transformer (CT) and Potential transformer (PT) are instrument transformers, which are used in conjunction with protective relays for protection purpose. The CT ... from the healthy part. In this way the CT and PT can be used for protection purpose.

Description : For complete protection of a three-phase line: A) three Phase relays and three Earth fault relays are required B) three Phase relays and two Earth fault relays are required C) two Phase relays and two Earth fault relays are required D) two Phase relays and one Earth fault relay are required

Last Answer : For complete protection of a three-phase line: two Phase relays and one Earth fault relay are required

Description : Which type of protection is provided on a generator to protect against stator insulation failure? A) Differential protection B) Overcurrent relay C) Thermocouple actuated alarm D) Reverse power relay

Last Answer : Which type of protection is provided on a generator to protect against stator insulation failure? A) Differential protection B) Overcurrent relay C) Thermocouple actuated alarm D) Reverse power relay 

Description :  For the protection of parallel feeders fed from one end, the relays used are: A) non-directional relays at the source-end and directional relays at the load-end B) non-directional relays at both the ... at the source-end and non-directional at the load-end D) directional relays at both the ends

Last Answer : For the protection of parallel feeders fed from one end, the relays used are: non-directional relays at the source-end and directional relays at the load-end

Description : A loss of excitation protection scheme for large generating unit employs A) under frequency relays B) offset Mho relay C) reactance relay D) percentage differential relay

Last Answer : A loss of excitation protection scheme for large generating unit employs offset Mho relay

Description : For complete protection ofa 3— phase line: (1) Three phase and three—earth fault relays are required (2) Three phase and two—earth fault relays are required (3) Two phase and two—earth fault relays are required (4) Two phase and one-earth fault relays are required

Last Answer : For complete protection ofa 3— phase line: Two phase and one-earth fault relays are required

Description : The type of backup protection scheme widely used in the field is (A) Relay backup (B) Breaker backup (C) Remote backup (D) Auxiliary backup

Last Answer : The type of backup protection scheme widely used in the field is Remote backup 

Description : Blind spot is a point in the zones of protection where

Last Answer : Blind spot is a point in the zones of protection where No protection is available.

Description : A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

Last Answer : D

Description : A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

Last Answer : A negative sequence relay is used for protection of Generator 

Description : For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester

Last Answer : For protection of rotating machines against lightning surges combination of lightning arrester and capacitor is used. 

Description : Reactance relay is normally preferred for protection against

Last Answer : Reactance relay is normally preferred for protection against earth faults

Description : Surge absorbers are used for protection against

Last Answer : Surge absorbers are used for protection against low voltage high frequency oscillations

Last Answer : Protection by fuses is generally not used beyond 100 A .

Last Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Last Answer : Overfluxing protection is recommended for generator transformer of the power plant.

Last Answer : The single phasing relays are used for the protection of three phase motors.

Last Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Last Answer : The delay fuses are used for the protection of motors.

Last Answer : H.R.C. fuses provide best protection against short-circuits.

Last Answer : A thermal protection switch can protect against overload.

Description : Primary and Backup Protection

Last Answer : Primary and Backup Protection  B,D,G,I are the primary protection. A,C,H,J are the backup protection. About 90% of faults are clear by Primary Protection. So ... ordinated backup (primary is at various station  and backup is at control room with computer)

Description : Explain construction and operation of induction type directional over current relay.

Last Answer : Directional overcurrent relay: Construction: It consists of two units: i) Non-directional Over-current unit ii) Directional power unit The directional unit consists of upper electromagnet ... closes the trip circuit. This operates circuit breaker which isolates the faulty section. 

Description : The burden value in Potential Transformer (PT) should be ______ to achieve low errors in PT: A) low B) high C) medium D) infinite

Last Answer : The burden value in Potential Transformer (PT) should be high to achieve low errors in PT: 

Description : Which of the following is not a part of transformer installation?  (A) Conservator (B) Breather (C) Buchholz Relay (D) Exciter

Last Answer : Which of the following is not a part of transformer installation?  (A) Conservator (B) Breather (C) Buchholz Relay (D) Exciter

Description : The core construction is like spokes of a wheel in following transformer:  (A) Berry Type Transformer (B) Core Type Transformer (C) Shell Type Transformer (D) None of the above

Last Answer : The core construction is like spokes of a wheel in following transformer:  Berry Type Transformer

Description : IDMT relays are used to protect the transformer against :  (A) Internal short -circuits (B) Open circuits (C) External short circuits (D) Oil leakage

Last Answer : IDMT relays are used to protect the transformer against : External short circuits

Description : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  (1) second harmonic current  (2) third harmonic current  (3) fifth harmonic current  (4) seventh harmonic current

Last Answer : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  second harmonic current 

Description : To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ?

Last Answer : To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ? Δ-Δ connection

Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Description : What is the use of Buchholz relay in transformer?

Last Answer : This is a transformer that is used to step up and down current. 

Description : What is over fluxing protection in transformer?

Last Answer : If the turns ratio of the transformer is more than 1:1, there will be higher core loss and the capability of the transformer to withstand this is limited to a few minutes only. This phenomenon is called over fluxing.