What are the parts of AC motor?
Show More
60 views
0 answers
asked
Mar 15, 2018
by
anonymous

What is the principle of AC motor?
Show More
68 views
0 answers
asked
Mar 15, 2018
by
anonymous

Last Answer : Induction motor is a AC motor it is also known as asynchronous motor .
Show More
101 views
1 answer
asked
Sep 9, 2017
by
anonymous

Last Answer : If a D.C. motor is connected across the A.C. supply it will burn due to heat produced in the field winding by eddy currents.
Show More
104 views
1 answer
asked
Mar 20, 2018
by
anonymous
.jpg)
Last Answer : A.C. series motor as compared to D.C. series motor has smaller brush width, less number of field turns, more number of armature turns, less air gap.
Show More
137 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : If a D.C. series motor is operated on A.C. supply, it will spark excessively, have poor efficiency, have poor power factor.
Show More
92 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : In a A.C. series motor armature coils are usually connected to commutator through resistance.
Show More
161 views
1 answer
asked
Mar 20, 2018
by
anonymous

State the modification to be done in dc series motor to work satisfactorily as ac series motor. State applications of ac series motor.
Last Answer : Modifications are necessary in a dc series motor so that it operates satisfactorily on ac supply. The modifications are as follows: 1) AC series motor is built with a few field turns as ... and grinders 5) High speed vacuum cleaners 6) Sewing machines 7) Food processors 8) Drilling machine
Show More
389 views
1 answer
asked
May 7, 2020
by
anonymous
.jpg)
The direction of rotation of an inverter fed 3-phase ac motor is reversed by (A) a mechanical reversing switch (B) reversing the input dc link voltage (C) operating the inverter as a rectifier (D) changing the sequence of switching
Last Answer : The direction of rotation of an inverter fed 3-phase ac motor is reversed by changing the sequence of switching
Show More
153 views
1 answer
asked
Apr 28, 2018
by
anonymous

Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.
Show More
146 views
1 answer
asked
Mar 20, 2018
by
anonymous

A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be
Last Answer : Leading
Show More
568 views
2 answers
asked
Apr 28, 2018
by
anonymous

UNIT 1 fundamentals of AC rotating machine Contents 1.1 Introduction 1.2 Advantages 1.3 Parts of AC machines 1.4 Synchronous speed 1.5 AC winding 1.6 Winding factor ( ... alternator or generator 1.9 Numericals 1.10 Harmonic 1.11 Slot harmonics 1.12 Harmonics minimization
Last Answer : 1.2 Advantages: In practices most of alternator have rotating magnetic field type construction with stationary armature due to following reason. The generation level of AC voltage may be in the range ... at high speed. Only two Slip rings are required to excited the field by AC supply.
Show More
228 views
2 answers
asked
Aug 25, 2018
by
Notes
.jpg)
What is the difference between an AC and DC generator?
Last Answer : The generator which generates DC voltage is called DC generator and generator which generates AC voltage is called AC generator (or) Alternator. In DC generator armature is rotated and field winding ... generator. A DC generator can generate low voltages but an AC generator can generate upto 11kv.
Show More
319 views
1 answer
asked
Mar 15, 2018
by
anonymous

Split phase induction motor
Last Answer : Split phase induction motor : There are two windings used in split phase induction motor. It is a type of single-phase induction motor. There are two winding one is called main winding and ... motor have low starting torque it is used for small fans, blowers, centrifugal pumps, grinders etc.
Show More
233 views
1 answer
asked
Sep 20, 2018
by
anonymous

Describe the reason of using dc series motor for electric trains.
Last Answer : Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains
Show More
142 views
1 answer
asked
Sep 18, 2018
by
anonymous

A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be
Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V
Show More
489 views
1 answer
asked
May 8, 2018
by
anonymous

Damper winding in a synchronous motor
Last Answer : Damper winding in a synchronous motor Serves to start the motor.
Show More
88 views
1 answer
asked
May 8, 2018
by
anonymous
.jpg)
In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.
Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.
Show More
137 views
1 answer
asked
May 8, 2018
by
anonymous

A change of 4% in the supply voltage to an induction motor will produce a change of approximately
Last Answer : A change of 4% in the supply voltage to an induction motor will produce a change of approximately 8% in the rotor torque
Show More
492 views
1 answer
asked
May 8, 2018
by
anonymous

A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm
Show More
343 views
1 answer
asked
May 3, 2018
by
anonymous

In an induction motor if the flux density is reduced to one-half, of its normal value then the torque will (1) reduce to one-half (2) reduce to one-fourth (3) remain unchanged (4) increase four times
Last Answer : In an induction motor if the flux density is reduced.to one-half, of its normal value then the torque will reduce to one-fourth
Show More
374 views
1 answer
asked
May 1, 2018
by
anonymous

The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque (1) Decreases (2) Increases (3) Remains constant (4) None of the above
Last Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases
Show More
239 views
1 answer
asked
May 1, 2018
by
anonymous

The number of poles of 8/6 stepper motor can be :
Last Answer : The number of poles of 8/6 stepper motor can be : 4
Show More
286 views
1 answer
asked
Apr 30, 2018
by
anonymous

In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :
Last Answer : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075
Show More
112 views
1 answer
asked
Apr 29, 2018
by
anonymous

For using regenerative breaking, the most suitable motor is : (A) DC series motor (B) Slip ring induction motor (C) Squirrel cage induction motor (D) Synchronous motor
Last Answer : For using regenerative breaking, the most suitable motor is : Slip ring induction motor
Show More
93 views
1 answer
asked
Apr 29, 2018
by
anonymous

Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be
Last Answer : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be 25 N -m
Show More
436 views
1 answer
asked
Apr 29, 2018
by
anonymous

The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is
Last Answer : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 4 percent
Show More
365 views
1 answer
asked
Apr 29, 2018
by
anonymous

A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for
Last Answer : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for 4 poles
Show More
311 views
1 answer
asked
Apr 29, 2018
by
anonymous

The function of a brush and commutator arrangement in a dc motor is to (1) produce unidirectional torque (2) produce unidirectional current in the armature (3) help in changing the direction of rotation of the armature (4) reduce sparking
Last Answer : The function of a brush and commutator arrangement in a dc motor is to produce unidirectional torque
Show More
2.5k views
1 answer
asked
Apr 29, 2018
by
anonymous

The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm
Last Answer : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm
Show More
158 views
1 answer
asked
Apr 28, 2018
by
anonymous

In a split-phase induction motor, the resistance/reactance ratios of windings are such that (A) current in the auxiliary winding leads the current in the main winding (B) current in the ... (C) both windings develop the same starting torque (D) both windings develop high starting current
Last Answer : In a split-phase induction motor, the resistance/reactance ratios of windings are such that current in the auxiliary winding leads the current in the main winding
Show More
107 views
1 answer
asked
Apr 28, 2018
by
anonymous

In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor
Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction
Show More
95 views
1 answer
asked
Apr 28, 2018
by
anonymous

The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu
Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu
Show More
100 views
1 answer
asked
Apr 28, 2018
by
anonymous

The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.
Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor
Show More
575 views
1 answer
asked
Apr 28, 2018
by
anonymous

A 3-phase, 4-pole, 50Hz induction motor runs at a speed of 1440 rpm. The rotating field produced by the rotor rotates at a speed of ________ rpm with respect to stator field. (A) 1500 (B) 0 (C) 1440 (D) 60
Last Answer : 0
Show More
2.1k views
2 answers
asked
Apr 28, 2018
by
anonymous

An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW
Last Answer : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is 83.33 kW
Show More
180 views
1 answer
asked
Apr 28, 2018
by
anonymous

The torque developed by any 3-phase induction motor at 0.8 p.u. slip is (A) Full-load torque (B) unstable torque (C) starting torque (D) break down
Last Answer : The torque developed by any 3-phase induction motor at 0.8 p.u. slip is unstable torque
Show More
3.1k views
1 answer
asked
Apr 28, 2018
by
anonymous
.jpg)
In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is (A) 0.2 Ω (B) 0.3 Ω (C) 0.4 Ω (D) 0.5 Ω
Last Answer : In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is 0.3 Ω
Show More
169 views
1 answer
asked
Apr 28, 2018
by
anonymous

Last Answer : In variable speed motor a weaker commutating field is needed at low speed than at high speed.
Show More
65 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : If a D.C. motor designed for 40°C ambient temperature is to be used for 50°C ambient temperature, then the motor is to be derated by a factor recommended by manufacturer and select the next higher H.P. motor.
Show More
99 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : Series motor has the poorest speed control.
Show More
103 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.
Show More
168 views
1 answer
asked
Mar 20, 2018
by
anonymous

The speed of a D.C. motor can be controlled by varying 1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above
Last Answer : The speed of a D.C. motor can be controlled by varying 1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above
Show More
398 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : At the instant of starting when a D.C. motor is put on supply, it behaves like a low resistance circuit.
Show More
132 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : In case the back e.m.f. and the speed of a D.C. motor are doubled, the torque developed by the motor will remain unchanged.
Show More
231 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.
Show More
135 views
1 answer
asked
Mar 20, 2018
by
anonymous

As there is no back e.m.f. at the instant of starting a D.C. motor, in order to prevent a heavy current from flowing though the armature circuit?
Last Answer : As there is no back e.m.f. at the instant of starting a D.C. motor, in order to prevent a heavy current from flowing though the armature circuit a resistance is connected in series with armature.
Show More
189 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : The armature voltage control of D.C. motor provides constant torque drive.
Show More
95 views
1 answer
asked
Mar 20, 2018
by
anonymous
.jpg)
Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.
Show More
215 views
1 answer
asked
Mar 20, 2018
by
anonymous

Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.
Show More
144 views
1 answer
asked
Mar 20, 2018
by
anonymous