Main components of Diesel power station:

1) Diesel Engine 2) Engine Air intake system 3) Engine Fuel System 4) Engine Exhaust system 5) Engine cooling system 6) Engine Lubricating system 7) Engine Starting system 8) Diesel Engine Generator (Alternator) 

Related questions

Description : Applications of Diesel power station

Last Answer : Applications of Diesel Power Station:  1. It can be used as a standby (emergency) power plant to maintain continuity of supply. (Incase failure of main supply like hospital, Telephone exchange Radio ... 10. Diesel plants are widely used for generating power ranging from 100 to 5,000 H.P. 

Description : State the functions of fuel system and exhaust system of a diesel power station.

Last Answer : Fuel system: It supplies fuel to engine for combustion purpose. It consists of Fuel Pump: - It supplies fuel to engine for combustion purpose. Strainer: - Are provided to remove suspended impurities and ... most of the noise. Chimney:- To exhaust gases in the atmosphere as high as possible. 

Description : List out main components of Reactors. 

Last Answer : List the main components of Reactors:  1. Core 2. Nuclear fuel (U235) 3. Moderator 4. Control Rod 5. Reflector 6. Reactor vessel 7. Shielding  

Description : List out the four applications of diesel electric power plant.

Last Answer : Applications of Diesel Power Plant: 1. It can be used as a standby (emergency) power plant to maintain continuity of supply. (Incase failure of main supply like hospital, Telephone exchange Radio stations, ... 10. Diesel plants are widely used for generating power ranging from 100 to 5,000 H.P.

Description : State the function of following components of a nuclear power station: i) Moderator ii) Shielding iii) Control rod iv) Coolant 

Last Answer : i) Function of Moderator :- Moderator is to moderate or reduce the speed of fast neutron to help the fission process.  ii) Function of sheilding : Shielding is to protect environment, ... from reactor core and transfer it in heat exchanger for producing steam at high pressure and temperature. 

Description : List and state any four limitations of inter connected power station.

Last Answer : Limitations of inter connected power station:- 1) Initial cost of infrastructure of transmission line increases as length increases. 2) Interconnection required more automation which increases cost on ... capacity. But in absence of surplus power merits of interconnection cannot be obtain.

Description : State elements of diesel electric power plant with their functions. 

Last Answer : Elements of Diesel Power Plant with their function):   1) Diesel Engine: - This is the main component of the P.P. which develops mechanical power. 2) Engine air intake system: - Air ... fuel as per requirement. 10) Alternator: - Its function is to convert mechanical power into electrical power.

Description : State why nuclear power plants are used as base load plants and diesel power plants as a peak load plant. 

Last Answer : 1. Because of following points Nuclear power plant used as base load power plant:-  1. Nuclear power plants is very economical for producing bulk amount of electric power 2. Nuclear power plant is reliable ... . The plants can be put on load easily. 4. Diesel engines take less time to make OFF.

Description : State any two applications of diesel power plants.

Last Answer : Applications of Diesel Power Plant: 1. It can be used as a standby (emergency) power plant to maintain continuity of supply. (Incase failure of main supply like hospital, Telephone exchange Radio ... . The diesel units can be used to supply the auxiliaries for starting the large thermal plants.

Description : Explain starting system in diesel electric power plant.

Last Answer : Starting system in Diesel Electric Power Plant: It includes Storage battery, compressed air tanks, self-starter etc. The purpose of engine starting system is to rotate the engine initially while ... as Ammeters, Voltmeters, Wattmeters, Thermometers, Pressure gauges, Visible and audible alarm etc.

Description : Explain fuel system and air intake system in diesel electric power plant.

Last Answer : Fuel system and air intake system in diesel electric power plant :  Fuel system: It consists of storage tank, strainers, fuel transfer pump and all day fuel tank. The fuel oil is supplied ... Filters are provided to remove dust particles from air which may act as abrasive in the engine cylinder.

Description : State any four advantages and four disadvantages of diesel electric power plant. 

Last Answer : Advantages of Diesel electric power plant:- 1) The design and layout of Diesel electric power plant is simple. 2) It requires less space. 3) Time required for complete erection of diesel power plant is less ... . 9) The useful life is very short. 10) Availability of fuel in future may be limited.

Description : State the different types of engines in diesel power plant.

Last Answer : Types of engines in diesel power plant: 1) Two Stroke Diesel Engine 2) Four Stroke Diesel Engine

Description : What are the components of a power system?

Last Answer : generator Traansformer Conductors Insulators

Description : Compare the Nuclear power station with Hydro power station. 

Last Answer : SR. No.  Points Nuclear Power plant  Hydro Power station  1 Site/ Location Where there is ample supply of water is available, away from thickly populated areas to avoid radioactive ... Field Application As base load  Used as base load during as well as peak load 

Description : Classify condensers used in thermal power station. Explain each type in brief. 

Last Answer : Types of condenser: Classification: 1. Jet Condenser (Mixing Type) 2. Surface condenser (non Mixing type)  Explanation:-   1. Jet Condenser (Mixing Type) In Jet condenser the steam ... there in no direct contact between the steam and cooling water. This condensate is reused in boiler. 

Description : Explain the working of Hydro power station with schematic layout. 

Last Answer : Working of Hydro- Electric Power Plant: Water stored at high level by constructing dam across river. This stored water has potential energy. This stored water is passed to run the water ... energy and Alternator is coupled to water turbine which converts mechanical energy into electrical energy. 

Description : "Efficiency of thermal power station is low". — Justify. 

Last Answer : Justification: Efficiency of thermal power station is low":- Overall efficiency of T.P.P depends upon efficiency of boiler, turbine and alternator. The heat produced due to combustion of coal ... losses in thermal power plant is 71%, So efficiency of thermal power plant is less about 29% 

Description : State the types of radioactive waste generated in a nuclear power station. Explain the methods employed for their disposal.

Last Answer : Types of radioactive waste: The waste produced in nuclear power plant is in the form of solid, liquid & gases, 1. Solid Waste Disposal:-  Solid wastes removed from the reactor are very ... are measured. If it is safe then released to atmosphere at high level through large height chimney.

Description : "Hydro electric power station are not perennial power station". Justify.

Last Answer : Justification: The water utilized by the hydro power plants comes mostly from storage dams/reservoirs which get filled up during the monsoon rainy season. Such reservoirs are utilized for supplying ... are important. Hence "Hydro electric power stations are not perennial power station" 

Description : State the function of cooling tower and condenser in thermal power station.

Last Answer : 1. Condenser:   Function of condenser is to convert exhaust steam again into water by reducing its temperature with the help of cold water. Also it reduces back pressure of steam turbine 2 ... tower : The function of cooling tower is to reduce the temperature of water coming from condenser.

Description : State the purpose of surge tank and spill way in hydroelectric power station.

Last Answer : Surge tank :- A surge tank is the small reservoir or tank. It is open at the top. It is installed near Vale house of turbine. It avoids water hammer effect when load on turbine reduces. (It ... ; during floods etc. In this way spill way avoids damage of dam due to excess pressure of water.

Description : State any four factors governing Selection of site for thermal power station. 

Last Answer : Following Factors are to be considered:- 1. It should locate near coal mine. 2. Sufficient quantity of water should be available. 3. Sufficient large space should be available. 4. It should be located ... laws of the land and the town planning. 14. The interests of national defense must be served.

Description : Write down any two advantages of nuclear power station.

Last Answer : Advantages of nuclear power station :-  1) Fuel required: Fuel requirment of Nuclear Power Plant is less than Thermal Power Plant. So it reduces transportation cost of fuel and space required for fuel storage ... By use of nuclear fuel.,it saves the other fossile fuels like-coal, gas, oil, etc.

Description : How Do I Build a Low Power FM Radio Station?

Last Answer : How Do I Build a Low Power FM Radio Station? A low power FM radio station offers individuals or small groups the ability to go on the air and communicate with the general public using FM radio ... FCC or your local government to determine which, if any FM frequencies you are allowed to transmit on.

Description : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Last Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Last Answer : Load factor of a power station is generally less than unity.

Last Answer : Load factor of a power station is defined as average load/maximum demand.

Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Description : List the different components used in CD player.

Last Answer : CD mechanism CD pick up assembly Gear system Motors CD lens Display panel Front panel Servo systems.

Description : List and explain the components of a hydraulic system.

Last Answer : Components Hydraulic: Hydraulic pump- Supply fluid to the components in the system. Pressure in the system develops in reaction to the load. Hence, a pump rated for 5,000 ... mechanical components and need to be removed along with other contaminants.  Seals, fittings and connections.

Description : What are the main components of a computer system?

Last Answer : CPU,monitor, keyboard and mouse

Description : State the functions of following elements: i) Diesel engine system ii) Air intake system iii) Engine exhaust system iv) Engine starting system.

Last Answer : i) Diesel engine system:-  Four strokes Two strokes ii) Air intake system:- Air intake system is provided to supply air to engine cylinder for fuel combustion.  iii) Engine exhaust system ... provided to rotate the engine initially until the firing starts and engine run under its own power. 

Description : Describe the process of photo emission. State the application of photo emission in electronic components

Last Answer : Process of Photoemission:when light of appropriate frequency and intensity is incident upon a surface of certain materials,the energy of light is given to electrons to leave the surface of metal ... photo tubes are used in door openers,counters, position and temperature control and colour analysis 

Description : Diesel Fuel Pumps

Last Answer : A diesel fuel pump, as the name suggests, is a pump for diesel engines. A diesel engine uses internal combustion to work. The pump is an essential component of the internal combustion process. The internal ... needs to be replaced because of damage, it is best to take the car to a repair shop.

Description : How to choose a diesel generator?

Last Answer : Diesel generators are widely used in various fields as the main or safety source of electricity. Stability in this case plays one of the most important roles, therefore, the choice of a ... purpose of the device, the most convenient and versatile are generators with an automatic control mode.

Last Answer : The efficiency of diesel locomotives is nearly 20 to 25 percent.

Last Answer : Overload capacity of diesel engines is usually restricted to 2 percent.

Last Answer : For diesel locomotives the range of horsepower is 1500 to 2500.

Description : Following are the components of jet engine

Last Answer : Following are the components of jet engine: 1. Air intakes 2. Compressors 3. Combustors 4. Turbines 5. Afterburners (reheat) 6. Nozzle 7. Bypass duct 8. Shaft

Description : What are the components of system bus? A) CPU Bus, Address Bus, Data Bus B) Memory, Control Unit, ALU C) Data Bus, Address Bus, Control Bus D) Register, PC, IR

Last Answer : What are the components of system bus? A) CPU Bus, Address Bus, Data Bus B) Memory, Control Unit, ALU C) Data Bus, Address Bus, Control Bus D) Register, PC, IR

Description : Which of the following are components of Central Processing Unit (CPU)?  (A) Arithmetic logic unit, Mouse  (B) Arithmetic logic unit, Control unit  (C) Arithmetic logic unit, Integrated Circuits  (D) Control Unit, Monitor

Last Answer : Which of the following are components of Central Processing Unit (CPU)?  (A) Arithmetic logic unit, Mouse  (B) Arithmetic logic unit, Control unit  (C) Arithmetic logic unit, Integrated Circuits  (D) Control Unit, Monitor

Description : The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

Last Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Description : Describe different RT level computational and sequential components used to design single function processors.

Last Answer : RT-level combinational components:- To reduce the complexity in digital logic, combinational components are used, which are more powerful than logic gates.  Such combinational ... during a clock edge. An asynchronous inputs value effects the circuit independent of the clock.

Last Answer : Categories of semiconductor components (Integrated circuit families) Integrated circuits are made from semiconductor material These are divided into three main categories A) ... minus, true or false etc. common families include Transistor Transistor Logic (TTL), CMOS, MOSFET.

Description : Sketch block diagram of satellite earth station and state functions of each block

Last Answer : The figure below shows the general block diagram of an earth station capable of transmission, reception and antenna tracking. The following are the major subsystems of ... , possible monitoring of satellite characteristics and occasionally for the measurement of special characteristics. 

Description : Define the following terms : (i) Base Station (ii) Control Channel (iii) Mobile Station (iv) Page 

Last Answer : i) Base Station: - A fixed station in a mobile radio system used for radio communication with mobile stations. Base stations are located at the center or on the edge of a coverage region ... the page throughout the service area using base stations which broadcast the page on a radio carrier.

Description : List the main parts of D.C. motor

Last Answer : Main parts of D.C. motor and their functions:  Part Functions Yoke i) Provides mechanical support for poles. ii) Acts as protecting cover for machine. iii) Carries magnetic flux. ... a fixed physical position relative to the stator.  Shaft Used to transfer mechanical power 

Description : What are the main electrical equipment used in HPS ? State the function of each parts of it in brief. 

Last Answer : Following Main Electrical Equipment used in HPS & their function: 1. Alternator 2. Exciter 3. Transformer 4. Switchgear   Function :  1) Alternator:- Alternator is coupled to ... part from the healthy section. It contains circuit breaker, relays, switches and other control devices.