Classify condensers used in thermal power station. Explain each type in brief. 

1 Answer

Answer :

Types of condenser:

Classification: 1. Jet Condenser (Mixing Type) 2. Surface condenser (non Mixing type)


 Explanation:-  

1. Jet Condenser (Mixing Type) In Jet condenser the steam and cold water comes in direct conduct with each other. Therefore cannot be used as feed water. 

 2. Surface condenser (non Mixing type) In surface condenser cold water is passed through pipes and steam is passed over these pipes. Due to cold water steam is again converted into water called as condensate. Since there in no direct contact between the steam and cooling water. This condensate is reused in boiler. 

Related questions

Description : "Efficiency of thermal power station is low". — Justify. 

Last Answer : Justification: Efficiency of thermal power station is low":- Overall efficiency of T.P.P depends upon efficiency of boiler, turbine and alternator. The heat produced due to combustion of coal ... losses in thermal power plant is 71%, So efficiency of thermal power plant is less about 29% 

Description : State the function of cooling tower and condenser in thermal power station.

Last Answer : 1. Condenser:   Function of condenser is to convert exhaust steam again into water by reducing its temperature with the help of cold water. Also it reduces back pressure of steam turbine 2 ... tower : The function of cooling tower is to reduce the temperature of water coming from condenser.

Description : State any four factors governing Selection of site for thermal power station. 

Last Answer : Following Factors are to be considered:- 1. It should locate near coal mine. 2. Sufficient quantity of water should be available. 3. Sufficient large space should be available. 4. It should be located ... laws of the land and the town planning. 14. The interests of national defense must be served.

Description : Explain ash disposal and dust collection in a thermal power plant.

Last Answer : Ash disposal:-  Various methods of disposal of ash are:  Mechanical handling system.  Pneumatic system. Hydraulic system  Steam jet system  Commonly used ash handling ... be done either manually or automatically.  This removed fly ash is collected in separate container

Description : Explain the working of Hydro power station with schematic layout. 

Last Answer : Working of Hydro- Electric Power Plant: Water stored at high level by constructing dam across river. This stored water has potential energy. This stored water is passed to run the water ... energy and Alternator is coupled to water turbine which converts mechanical energy into electrical energy. 

Description : State the types of radioactive waste generated in a nuclear power station. Explain the methods employed for their disposal.

Last Answer : Types of radioactive waste: The waste produced in nuclear power plant is in the form of solid, liquid & gases, 1. Solid Waste Disposal:-  Solid wastes removed from the reactor are very ... are measured. If it is safe then released to atmosphere at high level through large height chimney.

Description : State advantages of Pulverized coal w.r.t. thermal power plant. 

Last Answer : Advantages of Pulverized coal w.r.t. thermal power plant.  1. Due to pulvarization amount of fuel required to produce same amount of heat reduces. 2. Time required for combution reduces ... of air and thorough mixing of air and fuel, very high-combustion temperatures can be attained.

Description : State the function of super heater of a thermal power plant. 

Last Answer : Function of Super heater: -  Its function is to increase the temperature of steam by absorbing heat from exhausted hot flue gases.

Description : Write any four advantages and four disadvantages of thermal power plant.

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : The unit heat rate characteristic of a thermal power unit shows :  (A) Heat input per kWh of output versus the megawatt output of unit  (B) Heat input per kW of output versus the megawatt output ... hour output of unit  (D) Heat input per kW of output versus the megawatt hour output of unit

Last Answer : The unit heat rate characteristic of a thermal power unit shows : Heat input per kWh of output versus the megawatt output of unit 

Description : Compare the Nuclear power station with Hydro power station. 

Last Answer : SR. No.  Points Nuclear Power plant  Hydro Power station  1 Site/ Location Where there is ample supply of water is available, away from thickly populated areas to avoid radioactive ... Field Application As base load  Used as base load during as well as peak load 

Description : Applications of Diesel power station

Last Answer : Applications of Diesel Power Station:  1. It can be used as a standby (emergency) power plant to maintain continuity of supply. (Incase failure of main supply like hospital, Telephone exchange Radio ... 10. Diesel plants are widely used for generating power ranging from 100 to 5,000 H.P. 

Description : List out main components of Diesel power station. 

Last Answer : Main components of Diesel power station: 1) Diesel Engine 2) Engine Air intake system 3) Engine Fuel System 4) Engine Exhaust system 5) Engine cooling system 6) Engine Lubricating system 7) Engine Starting system 8) Diesel Engine Generator (Alternator) 

Description : State the function of following components of a nuclear power station: i) Moderator ii) Shielding iii) Control rod iv) Coolant 

Last Answer : i) Function of Moderator :- Moderator is to moderate or reduce the speed of fast neutron to help the fission process.  ii) Function of sheilding : Shielding is to protect environment, ... from reactor core and transfer it in heat exchanger for producing steam at high pressure and temperature. 

Description : "Hydro electric power station are not perennial power station". Justify.

Last Answer : Justification: The water utilized by the hydro power plants comes mostly from storage dams/reservoirs which get filled up during the monsoon rainy season. Such reservoirs are utilized for supplying ... are important. Hence "Hydro electric power stations are not perennial power station" 

Description : List and state any four limitations of inter connected power station.

Last Answer : Limitations of inter connected power station:- 1) Initial cost of infrastructure of transmission line increases as length increases. 2) Interconnection required more automation which increases cost on ... capacity. But in absence of surplus power merits of interconnection cannot be obtain.

Description : State the functions of fuel system and exhaust system of a diesel power station.

Last Answer : Fuel system: It supplies fuel to engine for combustion purpose. It consists of Fuel Pump: - It supplies fuel to engine for combustion purpose. Strainer: - Are provided to remove suspended impurities and ... most of the noise. Chimney:- To exhaust gases in the atmosphere as high as possible. 

Description : State the purpose of surge tank and spill way in hydroelectric power station.

Last Answer : Surge tank :- A surge tank is the small reservoir or tank. It is open at the top. It is installed near Vale house of turbine. It avoids water hammer effect when load on turbine reduces. (It ... ; during floods etc. In this way spill way avoids damage of dam due to excess pressure of water.

Description : Write down any two advantages of nuclear power station.

Last Answer : Advantages of nuclear power station :-  1) Fuel required: Fuel requirment of Nuclear Power Plant is less than Thermal Power Plant. So it reduces transportation cost of fuel and space required for fuel storage ... By use of nuclear fuel.,it saves the other fossile fuels like-coal, gas, oil, etc.

Description : The overall efficiency of Thermal Power Plant is equal to _______________ .  (A) Regenerative Cycle Efficiency (B) Renkine Cycle Efficiency (C) Carnot cycle efficiency (D) None of the above

Last Answer : The overall efficiency of Thermal Power Plant is equal to Regenerative Cycle Efficiency. 

Description : In a thermal power plant, ash is collected in

Last Answer : In a thermal power plant, ash is collected in hoppers or bunkers

Description : How Do I Build a Low Power FM Radio Station?

Last Answer : How Do I Build a Low Power FM Radio Station? A low power FM radio station offers individuals or small groups the ability to go on the air and communicate with the general public using FM radio ... FCC or your local government to determine which, if any FM frequencies you are allowed to transmit on.

Description : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Last Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Last Answer : Load factor of a power station is generally less than unity.

Last Answer : Load factor of a power station is defined as average load/maximum demand.

Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Description : Sketch block diagram of satellite earth station and state functions of each block

Last Answer : The figure below shows the general block diagram of an earth station capable of transmission, reception and antenna tracking. The following are the major subsystems of ... , possible monitoring of satellite characteristics and occasionally for the measurement of special characteristics. 

Description : Define thermal runaway.

Last Answer : Thermal runaway  The problem with increasing temperature causing increasing collector current is that more current increase the power dissipated by the transistor which, in turn, increases its temperature ... self-reinforcing cycle is known as thermal runaway, which may destroy the transistor. 

Description : Classify hydro-electric power plants according to water flow regulation and explain in brief.

Last Answer : Classification of hydro-electric power plants according to water flow regulation of water flow:-  1. Large reservoir power plant 2. Run-off river (ROR) power plant with poundage 3. Run-off River ... depends upon rate of flow of water Initial cost is less Its purpose is to generate electricity.

Description : Explain the thermal triggering method of SCR. Enlist different triggering methods of SCR.

Last Answer : Types of Triggering: 1) Forward voltage triggering 2) Thermal triggering (Temperature triggering) 3) Radiation triggering (Light triggering) 4) dv/dt triggering 5) Gate triggering ... generated leakage current increases. This current gets multiplied internally and thyristor is turned on. 

Description : Describe thermal runaway of transistor and explain how it can be avoided.

Last Answer : Concept of thermal runaway:  1.We know that  IC = β IB + (1+ β) ICO  Where ICO is the leakage current and ICO is strongly dependent on temperature. 2. Leakage current approximately doubles for ...   Thermal runaway can be avoided by : 1) Using stabilization circuitry 2) Heat sink 

Description : Define the following terms : (i) Base Station (ii) Control Channel (iii) Mobile Station (iv) Page 

Last Answer : i) Base Station: - A fixed station in a mobile radio system used for radio communication with mobile stations. Base stations are located at the center or on the edge of a coverage region ... the page throughout the service area using base stations which broadcast the page on a radio carrier.

Last Answer : Thermal overload relays are used to protect the motor against overcurrent due to heavy loads.

Last Answer : Thermal circuit breaker has delayed trip action.

Last Answer : A thermal protection switch can protect against overload.

Description : What are the maintenance schedules of a pumping station and type of starters?

Last Answer : Ans. Following are maintenance schedule of the pumping installation: Switch gear in every quarter and the motor & pump section every half yearly. Starters are DOL starter, star delta starter, Auto T/F starter.

Description : Explain captive power generation in brief

Last Answer : Advantages of captive power generation:  1. Reliability of supply increases. 2. Power quality is good. (Free from harmonics) 3. Transmission losses reduce as generation is nearby load centre ... . Same steam can be used for generation of electricity. Thus increase efficiency of industry.  

Description : Classify the transformers based on the construction, frequency and power.

Last Answer : Classification of Transformer Based On: i) Construction: Shell type, Core type, Berry type ii) Change in voltage level: Step-Up, Step-Down, iii) Number of phases: Single phase, Three phase iv) ... Control vi) Cooling: Self-cooled, Air-cooled, Forced-air cooled, Oil-cooled, Forced-oil cooled. 

Description : Explain working of thermal power plant.

Last Answer : Working of thermal power plant: In this power plant, coal is used as a fuel for combustion in combustion chamber. After combustion of fuel the heat is generated and this heat is given to the ... by using cooling water and this condensate again used for the boiler with the help of feed pump. 

Description : Where is the nearest nuclear power station to where you live?

Last Answer : There are a few nearby. If a Fukushima like event happened I would have to leave permanently.

Description : With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Last Answer : Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load. 

Description : Classify magnetic materials and explain in brief.

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { ... the absence of external magnetic field. Following are the ferromagnetic materials: Iron, Cobalt, Nickel.

Description : Briefly explain how the power factor of an inductive circuit can be improved.

Last Answer : As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

Description : Draw the block diagram of satellite sub-system and explain power subsystem.

Last Answer : POWER SUBSYSTEM- This system provides the necessary DC power to the satellite. All communication satellites derive their electrical power from solar cells. There is also a battery backup facility used during ... . to d.c. converter is used to raise the level of low voltages to high voltage.

Description : Explain the importance of solar power in the energy deficient India.

Last Answer : Mainly electricity generated in India is from -  Hydro power plant  Thermal power plant  Nuclear power plant  BUT,  To construct new Hydro power plant following are problem :- 1. There is ... start) 10. It saves the fossil fuel (coal, diesel, oil etc.) which are limited available.

Description : Explain the nuclear chain reaction in a nuclear power plant.

Last Answer : Nuclear chain reaction in a nuclear power plant: If a slow moving neutron hits unstable heavy nucleus of nuclear fuel U235 or Pu239 , the neutron is absorbed, the nucleus splits into two more ... chain reaction can be controlled and desired heat energy can be obtained in nuclear power plant. 

Description : Explain with block diagram photovoltaic power generation.

Last Answer : Photovoltaic power generation:  Photovoltaic power generating system consists of following components: 1. Photovoltaic cell panel: Its function is to convert energy content of sunrays directly into DC ... . Step-up transformer: It step-up input voltage to utilization voltage e.g. 230V.

Description : Explain starting system in diesel electric power plant.

Last Answer : Starting system in Diesel Electric Power Plant: It includes Storage battery, compressed air tanks, self-starter etc. The purpose of engine starting system is to rotate the engine initially while ... as Ammeters, Voltmeters, Wattmeters, Thermometers, Pressure gauges, Visible and audible alarm etc.

Description : Explain the procedure for disposal of nuclear power plant.

Last Answer : Disposal of nuclear waste: The waste products by nuclear fission may be solid, liquid or gas. i) Solid harmful disposals are packaged as required and shipped to a burial site for disposal. ii) Liquids ... and tested. If the required limits are met, these will be released to atmosphere.