Answer :

Advantage: Provides wide linear range. 2) Ability to measure reverses flow. 3) Gives rapid response to flow changes. 4) No obstruction is created to flow. 5) It can handle corrosive as well as slurry materials. 6) It has very low pressure drop. 7) Available in large size and capacity 


Applications: 1) They are used where applications involving measurement of erosive/corrosive slurries. 2) They are employed in measuring paper stock or pulp, as well as low flow rates and pipe networks with relatively short inside diameters. 3) It is useful for electrically conducting fluid.

Related questions

Description : State advantages and disadvantages of fiber optic communication

Last Answer : Advantage of fiber optic communication: 1.Greater information capacity/ higher bandwidth OFC's are capable of transmitting several gigabits per second over hundreds of miles allowing millions of ... are not flexible 7.Requiring more protection around the fiber cable compared with copper cable

Description : State advantages and disadvantages of continuous wave Radar

Last Answer : Advantages continuous wave RADAR : 1.Single frequency transmission and hence narrow receiver bandwidth 2.Duty cycle is unity, so mean power can be as high as transmitters will permits. 3.Ability ... required for receiver and transmitter. 3.Cannot detect targets crossing its beam at right angles.

Description : State the advantages and disadvantages of hydroelectric power plant.

Last Answer : Advantages of Hydroelectric power plant:-  1. There is no air pollution and other environmental problems. 2. The fuel (water) is available freely. 3. No fuel transportation cost so; there is ... , this can force the relocation of large numbers of riverside cities, towns, villages & people.

Description : State any two advantages and two disadvantages of nuclear power plant.

Last Answer : Disadvantages of Nuclear Power Plant: -   1. The capital cost of Nuclear power plant is very high as compare to other power plant of same capacity. 2. The erection & ... material could be released into the environment. Causing extensive damage to the mankind,animals and environment.

Description : State any four advantages and four disadvantages of diesel electric power plant. 

Last Answer : Advantages of Diesel electric power plant:- 1) The design and layout of Diesel electric power plant is simple. 2) It requires less space. 3) Time required for complete erection of diesel power plant is less ... . 9) The useful life is very short. 10) Availability of fuel in future may be limited.

Description : advantages and disadvantages of ICs.

Last Answer : Advantages of ICs: 1.The physical size of an IC is extremely small (generally thousand times smaller) than that of discrete circuits. 2. The weight of an IC is very less as compared to that of ... is high 3. Power dissipation is limited. 4. ICs are very delicate and need extra care while handling

Description : What are advantages and disadvantages of Mechatronics system? 

Last Answer : Advantages of Mechatronics system:  High level of integration.  Increased functionality and better design.  More use of electronics and software instead of mechanical function.  Assumes ... Its replacement is difficult, that it is difficult to change old system to new system. 

Description : Write any four advantages and four disadvantages of thermal power plant.

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : Write advantages and disadvantages of positive and negative feedback.

Last Answer : Advantages of Positive Feedback: i) Voltage gain increases. ii) No phase shift is provided. iii) Feedback signal and input signal are in phase. iv) Input and Output voltage increases.  ... ii) Feedback signal and input signal are out of phase. iii) Input and Output voltage decreases.

Description : Compare variable head flow meter with variable area flow meter.

Last Answer : Parameter Variable head flowmeter Variable area flowmeter Working principle Restriction or obstacle is placed in the path of flow to create a differential Pressure. The pressure ... viscous fluid slurries and dirty fluids. In laboratories and testing and production lines.

Description : Describe principle of operation of Doppler type ultrasonic flow meter with diagram. 

Last Answer : Diagram: Working:  The flow meter consists of a crystal transducer mounted outside the pipe in which flow is to be measured. This transducer is a piezoelectric crystal which ... , so the frequency of the reflected wave is shifted to particle velocity, according to Doppler principle.

Description : State advantages and disadvantages of radial distributor system. 

Last Answer : Advantages of radial distributor system: 1. Design of layout is simple. 2. Capital cost & Erecting cost is less as there is only one feeder. 3. Time required for completion of ... maintain supply to consumers when there is maintenance on feeder. 3. Voltage fluctuations are more.

Description : List advantages and disadvantages of MEMS.

Last Answer : Advantages : 1. Batch fabrication and hence reduced cost. 2. Reduced size and reduced power ( due to pin size and reduced package volume) 3. High precision and resolution. 4. Reduced ... cannot be loaded with large forces because brittle materials can be fractured easily under high stress.  

Description : Explain the advantages and disadvantages of using memory I/O and standard I/O.

Last Answer : Memory mapped I/O and standard I/O are the two methods for communicating microprocessor with peripherals. Processor talks to both memory and peripheral using the same bus.Two ways to talk to a peripheral. ... of standard I/O is no loss of memory addresses to the use as I/O addresses.

Description : What are the advantages and disadvantages of tidal power?

Last Answer : Free of costPollution freeLong life Less maintenance

Description : What are the advantages and disadvantages of wave energy?

Last Answer : AdvantagesFree from pollutionAvailable for every timeThe water can reuse as drinking purposeDisadvantageMore costLarge maintenanceDifficult to constructAquatic life get affected

Description : What are the advantages and disadvantages of solar energy?

Last Answer : Free of costRenewable energyInextable solar energyLow energy densityHigh capital costMaintenance cost highDepends on weatherNeed to direction tracking

Description : Draw venture meter and write steps to measure flow rate.

Last Answer : Venturi meter consists of three sections that is converging section, throat section and diverging section. The flow is introduced to the meter through the inlet with diameter D' . The inclined angle ... to 15o . Flow rate is proportional to the square root of the differential pressure.

Description : List variable flow meter. 

Last Answer : 1. Variable area : Rotameter 2. Variable head : a) Venturi b) Orifice c) Pitot tube d) Nozzle

Description : Write any two advantages of digital energy meter.

Last Answer : Advantages of Digital Energy Meter: 1) Easy to read. 2) High accuracy 3) High resolution. 4) No frictional losses as there are no moving parts. 5) No requirement for external adjustments. 6) Large ... due to absence of moving parts. 7) Highly efficient. 8) Very much compact. 9) Good reliability.

Description : State any two disadvantages of one wattmeter method of measurement of 3 phase power.

Last Answer : State any two disadvantages of one wattmeter method of measurement of 3 phase power. Disadvantages of one wattmeter method:- 1. Only used for balanced load 2. It can not be used for ... connection then neutral point must be available 4. Delta connection must be opened to connect current coil.

Description : What are the disadvantages of Open loop control system?

Last Answer : Open loop control system are less reliable. In open loop control system Optimization is not possible. Open loop control system are less accurate.

Description : Write any two disadvantages of hydro power plant.

Last Answer : Disadvantages of hydro power plant: i) Due to high cost of civil engineering works, the capital cost per kW of hydro plants is considerably higher than that of steam plants. ii) Hydro ... ) Hydro plant reservoir submerges huge areas, uproots large population and creates social and other problems. 

Description : Write any two disadvantages of ammeter shunts.

Last Answer : Disadvantages of ammeter shunts: 1. Errors are caused because of change in temperature. 2. Most suitable for DC measurement. 3. Power loss takes place.

Description : State the application of phase sequence indicator; clip on ammeter, frequency meter & P.F. meter.

Last Answer : Phase Sequence Indicator:  1. For finding correct phase sequence of supply  2. For obtaining exact instant of parallel operation of alternators.  3. For obtaining reversal of rotation ...  4. In electroplating industries   5. In various processes industries for measuring power factor

Description :  State the disadvantages of skin effect.

Last Answer : Disadvantages of skin effect:- 1. Full cross section of conductor is not utilized, Therefore effective area of conductor reduces so its resistance increases. 2. Due to increase in resistance, copper ... increases (Since Voltage drop = IR ) 5. So voltage regulation becomes poor (increases) 

Description : The main disadvantages of having poor power factors are:  (A) High cost of station and distribution equipment (B) Poor voltage regulation (C) High energy loss in conductor (D) All of the above

Last Answer : The main disadvantages of having poor power factors are:  (A) High cost of station and distribution equipment (B) Poor voltage regulation (C) High energy loss in conductor (D) All of the above

Description : What are the disadvantages of the linear regulator? how are they overcome in the switching regulator? What is continuous and discontinuous mode switching regulator?

Last Answer : Disadvantages of the linear regulator: Linear regulator waste power in the form of heat. Linear regulator has very low efficiency. Linear regulator cannot be used for the step ... between continuous mode and discontinuous mode switching regulator.

Description : What are the disadvantages of using solar energy?

Last Answer : High installation costEnergy density is depend on weatherSo it is low Not suitable in all areasMaintenance cost high

Description : What are some disadvantages of hydroelectric power plant?

Last Answer : The disadvantages of the hydroelectric power plant are as follows :The hydroelectric power plant can be developed only where the large quantity of water is available. The hydroelectric ... civil engineering costs may be high.These are some disadvantages of the hydroelectric power plant.

Description : what are the disadvantages of thyristor?

Last Answer : Disadvantages of thyristor The silicon controlled rectifier (SCR) is unidirectional devices, so it can control power only in DC power during positive half cycle of AC supply. Thus only DC power is ... cycle. It cannot be used at higher frequencies. The gate current cannot be negative

Description : State one application of clip on meter.

Last Answer : Clip-on meter is used to measure the High value AC current without breaking the circuit Or without opening the circuit.

Description : State the function and shape of following parts used in induction type energy meter: i) Series magnet ii) Shunt magnet iii) Al disc iv) Brake magnet

Last Answer : i) Series magnet: produce flux proportional to current (load current) of circuit and interact in the aluminum disc with flux produced by voltage magnet for torque production. Its shape is like letter U.  ii) ... : brakes the motion of the aluminum disc or slows it down. Its shape is like letter C. 

Description : State the meaning of creeping error in 1 phase energy meter.

Last Answer : Creeping error: It is defined as the slow and continuous rotation of the disc of the energy-meter when only pressure coil is energized with no current in the current coil (load current = 0). ... magnet on this iron wire is sufficient to prevent continues rotation of the disc on no load condition.

Description : State the use of shunt and series resistance used in extension of meter.

Last Answer : Use of shunt and series resistance: i) Use of shunt: To extend the range of Ammeter. ii) Use of series resistance: To extend the range of Voltmeter.

Description : Does current flow through a capacitor ?

Last Answer : Imagine a pipe with a flexible diaphram in the middle separating two haves of the pipe. Now the pipe is filled with air. If you apply a pressure to one end the diaphram will deform ... capacitor, the effects on electrons will be recreated across the boundary. But theres no electrical connection...

Description : Define laminar flow and turbulent flow.

Last Answer : Laminar flow : When a fluid flowing through the pipe at different speeds (fast at center and slow at edges), and the fluid particles move in layers with one layer sliding over the adjacent ... successive cross sections, then this flow is called as turbulent flow. Reynolds no is greater than 4000 

Description : Classify hydro-electric power plants according to water flow regulation and explain in brief.

Last Answer : Classification of hydro-electric power plants according to water flow regulation of water flow:-  1. Large reservoir power plant 2. Run-off river (ROR) power plant with poundage 3. Run-off River ... depends upon rate of flow of water Initial cost is less Its purpose is to generate electricity.

Description : Load flow studies involve solving simultaneous  (1) linear algebraic equations. (3) linear differential equations. (2) non-linear algebraic equations. (4) non-linear differential equations.

Last Answer : Load flow studies involve solving simultaneous non-linear algebraic equations.

Description : The current flow in a battery is due to ______ A) movement of ions B) movement of protons C) movement of holes D) movement of neutrons

Last Answer : The current flow in a battery is due to movement of ions

Description : lf the wire which is vertical to this page has electron flow downwards the conductor will have

Last Answer : lf the wire which is vertical to this page has electron flow downwards the conductor will have a counter-clockwise field in the plane of the paper

Description : Inductance affects the direct current flow?

Last Answer : Inductance affects the direct current flow at the time of turning on and off.

Description : Do electrons flow from the anode to the cathode?

Last Answer : electrons flow from cathode to anode because the electron has a negative charge and repels from the negatively charged cathode whilst also attracting to the positively charged anode.

Description : What is the flow of electrons from one atom to another called?

Last Answer : Electric current

Description : What is the direction of flow of current?

Last Answer : Current  flows  from  anode  to  cathode(opposite  direction  to  flow of  electrons)

Description : What is the direction of the flow of electrons?

Last Answer : Electrons  flow    cathode   to   anode  or  in   an  oposite  direction  of   convection  current  flow  or  holes.

Description : What is the direction of the conventional current flow?

Last Answer : The conventional current flow in opposite direction of flow of electrons. The electrons flow from negative terminal of battery to positive terminal of battery. And conventional current flow from positive terminal of battery to negative terminal of battery.

Description : What is the direction of flow of electric current in an electric circuit?

Last Answer : It  flows  from  anode  to  cathode  (direction  of   holes  flow)

Description : working of distortion factor meter with block diagram

Last Answer : Working : Initially the switch S is kept at position 1.The attenuator gets excluded and the bridge T network is adjusted for full suppression of fundamental frequency and hence we get ... is obtained on the meter.Thus the total rms distortion is indicated by the reading of attenuator. 

Description : Principal of digital frequency meter.

Last Answer : The basic block diagram of basic digital frequency meter (DFM) is shown in above figure. The signal whose frequency we have to be measured is first to be amplified through amplifier. The output of amplifier ... = Number of counts. t = Time interval between start and stop condition of the gate.