tern null as it applies to bridge measurement.

1 Answer

Answer :

Null measurements balance voltages so that there is no current flowing through the measuring device and, therefore, no alteration of the circuit being measured. Null measurements are generally more accurate but are also more complex than the use of standard voltmeters and ammeters, and they still have limits to their precision.

Related questions

Description : The bridge most suited for accurate measurement of relative permittivity of dielectric materials is (A) Carey Foster Bridge (B) Anderson’s bridge (C) Heaviside Bridge modified by Campbell. (D) Schering Bridge.

Last Answer : The bridge most suited for accurate measurement of relative permittivity of dielectric materials is Schering Bridge.

Description : sketch time period measurement by CRO.

Last Answer : Horizontal sweep is turned ON and the display appealing on the screen is adjusted by varying different control knobs provided on the front panel of CRO, till the signal is suitably displayed ... Where m=Number of division in one complete cycle n=Setting of time base =Time/Division

Description : different types of errors occurs in measurement.

Last Answer : Generally errors are classified into three types: systematic errors, random errors and blunders. 1) Gross Errors 2) Random Errors 3) Systematic Errors Instrumental Errors Environmental ... to wrong observations or reading in the instruments particularly in case of energy meter reading. 

Description : What are the factors influencing measurement errors?

Last Answer : The factor influencing measurement errors are accuracy, precision, range and bandwidth, sensitivity, resolution and uncertainty.

Description : What is measurement error ?

Last Answer : Measurement error :- Measurement is the process of comparing unknown quantity with known or standard quantity. Error is the difference between ... by fluctuations in reading measurement apparatus. Random error show different result for same repeated measurement.

Description :  operation of whetstone bridge. 

Last Answer : A Wheatstone bridge is widely used to measure the electrical resistance. This circuit is built with two known resistors, one unknown resistor and one variable resistor connected in the form of bridge. ... using a Wheatstone Bridge the unknown electrical resistance value can easily measure.

Description : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Last Answer : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Description : Units of Measurement

Last Answer : 1 horse power is 745.7 watts 1 horse power = work equal to lifting 550 lbs of weight to one foot for one second 1 calorie is equal to 4.2 Joules 1 barrel is equal to ... often chlorine or bromine. Use: as solvents, as aerosol propellants, in refrigeration. It is commonly used in refrigerator.

Description : List the different level measurement methods. 

Last Answer : Liquid Level Measurement Direct method 1. Hook type 2. Sight glass gype 3. Float type 4. Dip stick Indirect method 1. Hydraustatic pressure type 2. Electrical type a) Capacitance level indicator b) Radiation level detector c) Ultrasonic level gauge 3. Radar type

Description : Draw Bourdon tube with LVDT setup for pressure measurement.

Last Answer : Bourdon tube with LVDT setup for pressure measurement.

Description : State how pressure measurement can be done using Dead weight tester.

Last Answer : The handle is fully drawn out and the oil is allowed to enter in the cylinder (i.e. gauge and piston) The weight to be measured is placed on the platform. Now the handle is turned ... of the area of the piston and the pressure indicated on the gauge is equal to the weight under measurement.

Description : Define measurement and state the significance of electrical measurement system.

Last Answer : Measurement: Measurement is essentially a process in which magnitude of a quantity is determined in comparison with another similar quantity with significant units. OR The measurement of a given ... x) The measurement conforms the validity of hypothesis and also adds to its understanding.

Description : Name two methods for measurement of low, medium and high resistance. Give one advantage and one limitation of V- I method.

Last Answer : Methods for measurement of low resistance:  1. Ammeter voltmeter method  2. Kelvin's bridge method  3. Ohm meter method  4. Potentiometer method  5. Digital/analog multi-meter ... must be infinity for perfectly accurate measurement which is not possible.  2. Connection errors.

Description : State the significance of term measurement. 

Last Answer : Measurement is the quantitative comparison between unknown quantities with known standard. For doing this process there is need of physical device, called as measuring instrument. The measurement confirms the validity of the hypothesis and also adds to its understanding.

Description : Explain significance and purpose of electrical measurement system.

Last Answer : ➢ Significance of Electrical Measurement System  1. The measurement is required for measurement of all physical quantities for e.g speed, velocity, temperature, pressure etc.  2. All electrical ... 4. These standards and references may changes time to time, area to area person to person 

Description : Describe with working of LCR meter for measurement of inductance. 

Last Answer : working of LCR:- A LCR meter (Inductance (L), Capacitance (C), and Resistance (R) test equipment used to measure the inductance, capacitance and, resistance of a component. It works on the ... in parallel (as would be encountered in measuring a capacitor with a leaky dielectric) [Q setting ] 

Description : State any two disadvantages of one wattmeter method of measurement of 3 phase power.

Last Answer : State any two disadvantages of one wattmeter method of measurement of 3 phase power. Disadvantages of one wattmeter method:- 1. Only used for balanced load 2. It can not be used for ... connection then neutral point must be available 4. Delta connection must be opened to connect current coil.

Description : Explain V- I method of measurement of medium resistance. 

Last Answer : In this method, use suitable source, ammeter and voltmeter and connect them as shown in the above diagram. Take reading of voltmeter and ammeter, then value of resistance = R = V/I Ω To minimise the error take 4 to 5 observation for the same resistance and take their average.

Description : For measurement of radio frequency ac signals __________ type meter is used

Last Answer : For measurement of radio frequency ac signals thermo-couple type meter is used

Description : Measurement of a non -electrical quantity involves the following four subsystems:  a) amplifier block b) display block c) instrumentation block d) transducer block  The correct, sequence in which these block occur is  (1) d,a,c,b (2) d, c, a, b (3) a, c, b, d (4) a, b, c, d

Last Answer : Measurement of a non -electrical quantity involves the following four subsystems:  a) amplifier block b) display block c) instrumentation block d) transducer block  The correct, sequence in which these block occur is d,a,c,b

Description : Accurate measurement of very low resistances is possible with (A) Megger (B) Wheatstone Bridge (C) Kelvin’s Double Bridge (D) Wagner’s Earthing Device

Last Answer : Accurate measurement of very low resistances is possible with Kelvin’s Double Bridge

Last Answer : Commonly used instruments in power system measurement are induction.

Last Answer : For measurement of inductance having high value, we should use Hay's bridge.

Last Answer : For measurement of mutual inductance we can use Heaviside bridge.

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Description : How to Build a Bridge

Last Answer : How to Build a Bridge How to Build a Bridge Building a bridge is not an every day task, you do not see bridges going up overnight and it takes a skilled engineer to master this craft. Bridges ... this can be one of the most satisfying moments of your life to know that you have achieved your goal.

Description : How to Become a Bridge Inspector

Last Answer : How to Become a Bridge Inspector Bridge Inspectors are construction professionals who are well versed in a number of building disciplines. Among the talents of a bridge inspector are such ... secure employment in a variety of different settings, both in government agencies and private business.

Description : How to Become a Bridge Engineer

Last Answer : How to Become a Bridge Engineer Bridge Engineers are construction professionals that bear a major part of the responsibility for the safety and stability of bridges. Consequently, a bridge engineer ... new business. A well-established reputation is vital to the success of bridge engineering career.

Description : Draw circuit diagram of symmetrical configuration of bridge converter.

Last Answer : circuit diagram of symmetrical configuration of bridge converter

Description : List out advantages and disadvantages of bridge rectifier.

Last Answer : Advantages :  1. Bridge rectifier can be used in applications allowing floating output terminals i.e. not output terminal is grounded.  2. The need of center-tapped transformer is eliminated.  ... The value of the diodes used should be precise , else there will be an error in rectification

Description : Draw full bridge & half bridge configuration with common cathode.

Last Answer : Half Bridge Configuration: Full Bridge Configuration: 

Description : Give the operation of single phase full wave bridge controlled converter with RL load with a neat diagram. Also draw its waveform.

Last Answer : Single phase fully control bridge converter with RL load: 1. During positive half cycle of input voltage, T1 and T2 are forward biased and during negative half cycle, T3 and T4 are forward biased. Therefore, T1-T2 ... cycle till the firing of next pair of SCRs as shown in the waveform.

Description : Wheatstone bridge

Last Answer : Wheatstone bridge

Description : A dummy strain gage is used in a quarter bridge strain gage circuit to :  (A) compensate for changes in temperature and lead wire resistance  (B) produce more output voltage from the bridge  (C) increase the sensitivity of the bridge  (D) compensate lead wire resistance only

Last Answer : A dummy strain gage is used in a quarter bridge strain gage circuit to : compensate for changes in temperature and lead wire resistance 

Description : Which of the following is true with respect to Wien Bridge? A) It does not require equal values of R or C  B) It requires that R and C values of all components must be equal C) It requires that all resistors should have equal values D) None of these

Last Answer : Which of the following is true with respect to Wien Bridge? A) It does not require equal values of R or C  B) It requires that R and C values of all components must be equal C) It requires that all resistors should have equal values D) None of these

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Last Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Description : The bridge method commonly used for finding mutual inductance is (A) Heaviside Campbell bridge (B) Schering bridge (C) De Sauty bridge (D) Wien bridge

Last Answer : The bridge method commonly used for finding mutual inductance is Heaviside Campbell bridge

Last Answer : If an inductance is connected in one arm of bridge and resistances in the remaining three arms the bridge cannot be balanced.

Last Answer : In a Schering bridge the potential of the detector above earth potential is a few volts only.

Last Answer : In an Anderson bridge, the unknown inductance is measured in terms of known capacitance and resistance.

Last Answer : For measurements on high voltage capacitors, the suitable bridge is Schering bridge.

Description : A universal RLC bridge uses?

Last Answer : A universal RLC bridge uses Maxwell Wein bridge for measurement of inductance and modified De Santy's bridge for measurement of capacitance.

Description : Explain three phase bridge inverter.

Last Answer : Three phase bridge inverter: Three phase bridge inverter converts DC voltage input to three-phase variable frequency variable voltage output. DC voltage source can be a DC source or output of the rectifier. ... in proper sequence. The switch may be thyristor or IGBT etc.

Description : Explain the operation of full bridge converters with their different operating modes. State its advantages and disadvantages.

Last Answer : Full bridge converter: Full bridge converter provides isolation between input and output. Full bridge converter is used for step up or step down the input voltage. Full bridge converter consists of four power semiconductor ... Require filter on both input and output.

Description : explain blanking times for Bridge circuit?

Last Answer : Blanking time is provided by driver circuit to power switch. Blanking time is important because the turn on input of one transistor must be delayed with turn off input of another transistor if both ... are connected in one converter leg. This blanking time helps in avoiding cross conduction.

Description : What are the terms for the dimensions of a box? See detail.

Last Answer : Length, width, height.

Description : Show that the percentage error in the measurement of resistance by a metre bridge is minimum when the null point is near about the centre of the wire.

Last Answer : Show that the percentage error in the measurement of resistance by a metre bridge is minimum when the null point is ... B. 50 cm C. 80 cm D. 100 cm

Description : For dynamic strain measurement, the Wheatstone bridge used is of __________ type. (A) Voltage sensitive null (B) Voltage sensitive deflected (C) Current sensitive deflected (D) None of these

Last Answer : (B) Voltage sensitive deflected