i) Primary Distribution:

 It is a 3-phase, 3-wire transmission line connected in between receiving substation to Distribution substation. OR It is link between receiving substation & distribution transformer

ii) Secondary Distribution:

 It is a 3-phase, 4-wire Distribution line in between Distribution substation to consumer line. OR It is link between distribution transformer substation & consumer. 

Related questions

Description : State the losses in secondary distribution system. 

Last Answer : The losses in secondary distribution system: a) Technical losses: 1. Due to poor voltage 2. Due to unbalance load 3. Due poor quality of transformer & its components 4. Due to poor quality ... of induction type of energy meter. 3. Lack of administration. 4. Energy theft 5. Unmetered supply

Description : Compare primary and secondary instruments.

Last Answer : Primary instruments  Secondary instruments  Gives magnitude of quantity in terms of physical constants of instrument  Gives reading directly of the quantity measured.  Need no calibration  ... .  e.g. magnetic meter, induction meter, hotwire meter and electrostatic meter 

Description : In a transformer the resistance between its primary and secondary should be?

Last Answer : In a transformer the resistance between its primary and secondary should be infinity.

Description : Grid distribution system

Last Answer : Grid distribution system:-  In this system, when the feeder or loop or ring is charged (energized) by two or more than two substations from two or more than two different generating stations then it is known as “Grid distribution system. In this system only one feeder is utilized at a time. 

Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Description : requirements of a distribution system

Last Answer : Following requirements of a distribution system.  1. Layout should be simple in design. 2. It should have less initial cost 3. The distribution system should have minimum distribution ... stability of existing distribution system. 15. Time required for completion of work should be less. 

Description : Why radial distribution system used for short distance ? 

Last Answer : Because of following disadvantages radial distribution system is not used for long distance:  Since there is only one feeder to DTC feed at one point so, 1) There is no reliability ... more time for fault finding & repairing Hence radial distribution system is used for short distance.

Description : Explain following techniques related to energy conservation in transmission and distribution system. (i) By balancing phase currents (ii) Variable technical losses (I2R losses).

Last Answer : (i) Balancing Phase currents: Proper (healthy balanced) three phase loads always draw equal currents in all lines but single phase loads in the 3 phase 4 wire system or loads connected between two ... . 11) Minimize I2R losses. 12) Balance the load currents. 13) Regulate the system voltages.

Description : The permissible voltage variation in transmission and distribution system is:  (A) ± 0.1% (B) ± 1% (C) ±10% (D) ± 25%

Last Answer : The permissible voltage variation in transmission and distribution system is: ±10%

Description : The main criterion for selection of the size of a radial distribution system is

Last Answer : The main criterion for selection of the size of a radial distribution system is voltage drop

Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Description : State the condition for selecting site for distribution substation. 

Last Answer : Following condition should be considered while selecting site for distribution sub-station:-  1. Near load center :  Sub-station should be located near load center to reduce cost of Transmission and ... free from earthquake :  To avoid damage to sub-station area should be free earth quake. 

Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Description : What happens to the voltage in the secondary when the frequency of the supply in the primary is decreased? A) It increases B) It decreases C) It remains the same D) Cannot say unless the actual percentage increase in the frequency is known

Last Answer : What happens to the voltage in the secondary when the frequency of the supply in the primary is decreased? A) It increases B) It decreases C) It remains the same D) Cannot say unless the actual percentage increase in the frequency is known

Description : Write example of each type (i) Primary transducer (ii) Active transducer (iii) Electrical transducer (iv) Digital transducer

Last Answer : (i) Active transducer:-Thermocouple, piezoelectric, photovoltaic cell (ii) Primary transducer:- Bourdon tube, bellows, (iii) Electrical transducer.:- LVDT,RVDT, Hall effect, strain gauge, ... , optical pyrometer, radiation pyrometer (iv) Digital transducer:- Linear Encoder, digital taco generator

Last Answer : Primary winding of a transformer could either be a low voltage or high voltage winding.

Description : Primary and Backup Protection

Last Answer : Primary and Backup Protection  B,D,G,I are the primary protection. A,C,H,J are the backup protection. About 90% of faults are clear by Primary Protection. So ... ordinated backup (primary is at various station  and backup is at control room with computer)

Description : State the meaning of secondary instrument. Classify secondary instruments.

Last Answer : Secondary instruments: - Gives reading directly of the quantity being measured. - Calibrated with respect to absolute instruments  Classification of Secondary instruments:  1. Depending on the ... on permissible error: i) Standard meters ii) Substandard meters iii) First grade instruments.

Description : State the meaning of absolute instrument and secondary instrument. 

Last Answer : Absolute instruments:   These instruments read the quantity under measurement indirectly i.e. in terms of deflection, degrees and meter constant. The actual value under measurement can be calculated ... of operation (b) Depending upon permissible percentage error. (c) Depending upon application.

Description : Why CT is never operated with an open secondary ?

Last Answer : CT secondary should never be kept open because it will cause saturation of the core to a high level and very high voltage will appear across the secondary which can breakdown the insulation. One terminal of PT secondary is always grounded to avoid capacitive induction and for human safety

Description : Write difference between absolute & secondary instrument.

Last Answer : Absolute Instrument Secondary Instrument 1. These give magnitude of quantity in terms physical constants of instruments 1. These give reading directly of the quantity at the time of ... Raleigh current balance. 6. Examples - ammeter, voltmeter, amperehour meter, wattmeter etc.

Description : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Last Answer : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Description : Increasing the number of turns of wire on the secondary of a transformer will  (A) Decrease the secondary current (B) Increase the primary current (C) Have no effect on the secondary current (D) Increase the secondary current

Last Answer : Increasing the number of turns of wire on the secondary of a transformer will Decrease the secondary current 

Description : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side

Last Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Description : When secondary of a current transformer is open-circuited its iron core will be?

Last Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : The secondary of a current transformer is always short-circuited under operating conditions because it?

Last Answer : The secondary of a current transformer is always short-circuited under operating conditions because it avoids core saturation and high voltage induction.

Description : What do you mean by secondary instruments?

Last Answer : The instruments which will give the direct readings are called secondary instruments

Description : List classification of distributor system with their advantages each.

Last Answer : According to scheme of connection there are three types of distribution systems: - 1.Radial (Tree) distribution system 2.Ring mains (Loop) distribution system 3. Grid (interconnected) ... It has highest reliability to maintain supply even when there was maintenance on any one feeder.

Description : State advantages and disadvantages of radial distributor system. 

Last Answer : Advantages of radial distributor system: 1. Design of layout is simple. 2. Capital cost & Erecting cost is less as there is only one feeder. 3. Time required for completion of ... maintain supply to consumers when there is maintenance on feeder. 3. Voltage fluctuations are more.

Description : TRANSMISSION AND DISTRIBUTION MCQ

Last Answer : 51. It is difficult to maintain oil filled cables. (a) Yes (b) No Ans: a 51. In capacitance grading a homogeneous dielectric is used. (a) Yes (b) No Ans: b 52. In congested areas where excavation is ... The metallic sheath may be made of lead or lead alloy or of aluminium. (a) Yes (b) No Ans: b

Description : Distribution Boards –

Last Answer : Ans. a. Sub & Main Distribution Boards b. Schedule Maintenance.

Description : State the classification of distribution substation. 

Last Answer : The classification of distribution substation. 1. Pole mounted distribution substation 2. Plinth mounted distribution substation 3. Compact/prefabricated distribution substation 4. ... Indoor distribution substation 6. Outdoor distribution substation 7. Mobile distribution substation 

Description : Advantages of Grid distribution scheme

Last Answer : Advantages of Grid distribution scheme 1. Supply to distribution transformer center is given through two different generating stations or major generating stations 2. It has highest reliability to ... highest reliability to maintain supply even when there was maintenance on any one feeder. 

Description :  different types of distribution scheme.  

Last Answer : According to scheme of connection: -  a) Radial (Tree) distribution system  b) Ring mains (Loop) distribution system  c) Grid (interconnected) distribution system OR Types of ... distribution system  b) Ring mains (Loop) distribution system  c) Grid (interconnected) distribution system

Description : comparison between Feeder and Distribution

Last Answer : Sr.No Feeder Distributor 1 It is link between receiving substation & distribution transformer   It is link between distribution transformer substation & consumer  2 ... loading point is at substation only   Distributors loading point is throughout its length. 

Description : Write selection criteria of distribution transformer with any four points.

Last Answer : Selection Criteria for Distribution Transformer:  i) Ratings - The kVA ratings should comply with IS:2026 ( Part l )-1977*. The noload secondary voltage should be 433 volts for transformers to be ... is not necessary. vi) Cooling - The transformers covered in this group are generally ONAN, AN

Description : Explain with schematic diagram direct distribution of solar energy.

Last Answer : Explain with schematic diagram direct distribution of solar energy: Solar energy reaching earth's surface consists of two components: i) Direct solar energy, ii) Diffused solar energy. Direct solar energy ... radiation. It is very intense radiation and it can produce sun burns and shadows.

Description : The skin effect in conductors is due to non uniform distribution of current in it and major portion of current is near the _______ of conductor.  (1) Surface (2) Center (3) Complete cross section area (4) Axis

Last Answer : The skin effect in conductors is due to non uniform distribution of current in it and major portion of current is near the Surface of conductor. 

Description : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Last Answer : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Last Answer : Service mains are the conductors, which connect the consumer's terminals to the distribution.

Last Answer : In a power or distribution transformer about 10 percent end turns are heavily insulated to withstand the high voltage drop due to line surge produced by the shunting capacitance of the end turns.

Description : Define measurement and state the significance of electrical measurement system.

Last Answer : Measurement: Measurement is essentially a process in which magnitude of a quantity is determined in comparison with another similar quantity with significant units. OR The measurement of a given ... x) The measurement conforms the validity of hypothesis and also adds to its understanding.

Description : Describe the use of Pneumatic system in daily life.

Last Answer : I. Automatic tyres are inflated with compressed air. II. Spray guns use compressed air for spraying paints. III. Compressed air is used in air powered tools like hammers and drills IV. It is also used in air brake system in heavy vehicles.

Description : Write short note on UPS and its usage in railway system.

Last Answer : Ans. Ideally, the voltage supply by the utility system should be perfect sine wave without any harmonics, at its nominal frequency of 50 Hz and at its nominal magnitude. In practice however voltage can ... load from one source to the other results in the least amount of disturbance seen by the load.

Description : Septic System Design

Last Answer : Most people, when they get their own property, take all their time designing and building the house first and worry about the septic system later. For the most part it works out just fine, the house is built ... that it's a bad choice-it isn't-but it's practical to always go for the least expensive.

Description : The Lymphatic System

Last Answer : An Overview of the Lymphatic System The lymphatic system refers to a type of network in the body that consists of the lymphoid organs, lymphatic tissues, lymph ducts, lymph nodes, lymph vessels and ... many ways in which the lymphatic system takes action in a lot of the human body's processes.

Description : Septic System Maintenance

Last Answer : Nobody is interested in thinking about what happens when someone forgets to clean his or her septic system in the backyard. We don't need to tell you either. Not draining and cleaning your septic ... its regular cleaning schedule you don't have to worry about the system breaking down anytime soon.

Description : Septic System Cleaning

Last Answer : A septic tank requires cleaning to remove the scum or solid wastes that have accumulated in it over the years. The modern septic system was designed to allow liquid waste to flow freely back out as ... from clogs and impurities? Remember, when the tank goes, the system goes. Take note of that.

Description : How To Make A Sprinkler System

Last Answer : Watering plants can be quite tiresome, especially for huge gardens. You will have to walk through the maze of shrubs, blooms and rocks just to sprinkle every garden plant with water. Thanks to human ... 't join the show American Inventor with this invention; this writer would not be very happy.

Description : How to Choose a Home Security System

Last Answer : How to Choose a Home Security System Burglars can strike the moment your house is left alone or when everyone's asleep. Even if all the doors are locked, some of them can still enter using their ... protected upon the trigger of an alarm or a flick of a switch from the system's control panel.