what is the use of bedding on underground cable?
1.Maintenance is less.
2.Underground cables also useful for keep the city to be neat n good for looking .
3.To avoid lightening ( accidents & damages).
this is comments section.. you can answer this question by using Answer box.

1 Answer

Answer :

Bedding is the layer above the  lead sheath  it protects the lead sheath from corrosion that means it gives chemical protection to metallic sheath(lead sheath)
Like 0 like

Please log in or register to answer this question.

Related questions

189 views

Description : State the procedure for laying / installation of underground cable.  

Last Answer : 1) Direct laying Cable: or Trench laying method: Procedure: * For laying of a cable trench about 1.5m deep and 0.5m wide is made along the cable route. * A ... over. * Cables laid in this manner are usually plain lead covered because troughing affords good mechanical protection. 

1 answer
1.0k views

Description : If the insulation resistance of a cable of length 10 km is 1 mega ohm, its insulation resistance for 50 km length will be

Last Answer : If the insulation resistance of a cable of length 10 km is 1 mega ohm, its insulation resistance for 50 km length will be 0.2 mega ohm

1 answer
291 views

Description : Draw and explain the construction of underground cables. 

Last Answer : Underground cables:   OR Explanation:- i) Core or conductor: * It function is carry current. * Cable may have single or more than single core conductor. * Conductor ... handling of cables. * It is similar to bedding & consists of fiborous material such as jute. 

1 answer
64 views

Description : Differentiate between overhead transmission and underground transmission.

Last Answer : Points Overhead line  Underground cable Capital cost  Less More Erecting cost  Less More Time require for completion of work Less More Flexibility More ... Space consumed Space consumed  No space consumed Appearance Not good  Very good 

1 answer
110 views

Description : Why don't we burry power lines underground ?

Last Answer : Because conductor used for power transmission are not insulated and if we do so it create phase to ground fault causing interruptions to supply.

5 answers
130 views

Description : Why underground service connections are service connections are costly than overhead service connection

Last Answer : Reason: Underground service connection is given by underground cable. This cable is costly than bare conductor. Sometimes cable trench is required for cable laying, which requires additional cost. So underground service connections are costly than overhead service connection.

1 answer
116 views

Last Answer : The underground system cannot be operated above 66 kV.

1 answer
265 views

Description : State the four methods of laying of cable. State precautions while laying of underground cable in the situation : (i) Minimum clearance between cable and water pipe line when running in parallel. (ii) ... is to be laid in the same trench, what should be minimum spacing between two cables ?  

Last Answer : (i) Minimum clearance between cable and water pipe line when running in parallel:- 0.5 mtr. (ii) Minimum clearance between cable and water pipe line when running in parallel:- 0.5 mtr ... should be minimum spacing between two cables :- Then minimum 30 cm spacing is provided between 2 cables 

1 answer
3 views

Description : Where have all the fire hydrants gone?

Last Answer : I have a yellow one in my yard. My house insurance was discounted because of that.

1 answer
2 views

Description : I have 10 minutes to decide whether to cancel my cable help me choose?

Last Answer : Do it. Piracy is free. Just avoid the torrents.

1 answer
0 views

Description : How do I set up a Universal Remote Control to my Suddenlink cable box?

Last Answer : answer:

1 answer
1 view

Description : Does anyone have the USB GO! Link Cable?

Last Answer : You can usually get drivers and related software from the manufactures web page.

1 answer
2 views

Description : Where can I get an HSSDC to USB cable or similar.

Last Answer : I would call tyco electronics or amphenol customer service and see if they have any standard cable assemblies. They might have some in their sample stock. It's possible that this isn't a standard and the wiring ... match up though. I work for TE and I've never heard of a HSSDC to USB cable assembly.

1 answer
1 view

Description : Why is the death penalty a non-view event when it could be assessible to all by cable?

Last Answer : I agree that it shouldn't be shied away from- especially if one supports it. However, showing it on television would violate a few laws. So to get around those it would have to be either a pay ... I just don't see how it will happen with the way our communication and broadcasting system is set up.

1 answer
0 views

Description : Where can I find a CNT or LMR 400 cable?

Last Answer : Check your local Radio Shack store or Order Online -> http://www.google.com/products?hl=en&source=hp&q=CNT%20or%20LMR%20400%20cable&rlz=1R2ADSA_enUS360&oq=&um=1&ie=UTF-8&sa=N&tab=wf

1 answer
0 views

Description : How can I use a multimeter to find out how many OHMS are in a cable?

Last Answer : Measure the potential difference (V) across the cable and the current (I) running through it. Then use Ohm’s law: V = IR. R is the resistance, given in ohms, where 1 ohm is 1 volt divided by 1 amp.

1 answer
1 view

Description : I can't find this cable anywhere!

Last Answer : Ahem

1 answer
0 views

Description : Why do we now have commericals on cable television?

Last Answer : Not the defend the cable companies, but their operating and infrastructure costs are constantly going up. The money’s got to come from somewhere.

1 answer
0 views

Description : Can I cut a cable wire?

Last Answer : probably best just to feed it into the hole, if possible. you may want it later. but, if you're sure you won't, then,yes, you can.

1 answer
136 views

Description : desirable properties of Cable

Last Answer : Following are the main properties of cables:  1. Stranded Conductor: The conductor used for cable should be stranded specially for large size of cable because,  To increase the flexibility ... and mechanical injury.  7. Life: The material used for cable should have long life. 

1 answer
75 views

Description : Why is "RJ-45" cable called "RJ-45" ?

Last Answer : rj = registered jack 45 = is number of standard interface and contains 8 separate wires

2 answers
786 views

Description : Why cable outer sheath is black in color?

Last Answer : There are cables with different colors, for example, red, orange, grey. PVC or HDPE, the plastics that the jacket of the cable is made of, have to be UV-stabilized. Carbon black is a common and cheapest additive for it purpose

5 answers
111 views

Description : What is the difference between a cable and a conductor?

0 answers
551 views

Description : How rating of main switch and cable is selected for Industrial Installation.

Last Answer : 1. Rating of Main Switch or Fuse Rating is decided in industrial installation: Rating of main switch or fuse is based up the starting current of motor. For calculating starting current is considered 2 ... take 1.5 times the rated current or full load current. & thus cable rating is decided.

1 answer
150 views

Description : State functions of ; i) Cable box ii) Guard wire iii) Shackle insulator iv) Stay wire used in service connection

Last Answer : i) Function of Cable box: To hold and inspect incoming and outgoing terminals  ii) Function of Guard wire : A grounded conductor placed beneath an overhead transmission line in order to ground ... in service connection: To give mechanical Support to pole, line and prevent leakage current if any

1 answer
598 views

Description : The velocity of travelling wave through a cable of relative permittivity 36 is

Last Answer : The velocity of travelling wave through a cable of relative permittivity 36 is 0.5 x 108 m/sec

1 answer
188 views

Description : A single core lead sheathed cable with two dielectrics of permittivity 4 and 3, respectively, are subjected to same maximum stress. If the conductor diameter is 1.5 cm, the outer diameter of the first dielectric is (A) 1.125 cm (B) 1.5 cm (C ) 2 cm (D) 8 cm

Last Answer : A single core lead sheathed cable with two dielectrics of permittivity 4 and 3, respectively, are subjected to same maximum stress. If the conductor diameter is 1.5 cm, the outer diameter of the first dielectric is 2 cm 

1 answer
761 views

Description : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

Last Answer : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is 22.0 mm

1 answer
102 views

Description : What is the lowest acceptable insulation resistance for a cable?

0 answers
1 view

Description : Would you educate me on streaming devices for our TV?

Last Answer : answer:Easiest to use streaming device is probably a google chrome cast. Plugs into the HDMI slot in the back of the TV, controllable via Google Chrome. Runs $35. Do you subscribe to any streaming services, ... and good wi-fi? You need an extremely tall antenna to get a signal from 60 miles away.

1 answer
5 views

Description : Why would this be happening to my ask-public account?

Last Answer : answer:You are in Comcast's walled garden' - basically their records in Comcastville do not have the MAC address (those 12 digits on the bottom of your modem) and so they won't let you outside ... week. It's nothing serious - just bureaucratic. Either reactivate on line or phone them. No big deal.

1 answer
1 view

Description : Digital strength low...what does that mean?

Last Answer : answer:Probably a break in the cable to your house. Coincidence that it coincided with getting a new TV. Call your cable company. But personally, I’d save myself $20 a month and get an amplified antenna from Radio Shack.

1 answer
1 view

Description : The Real L Word; before I give it a go (and watch it), is it any good, or garbage?

Last Answer : It’s no better than any other reality tv show meaning it’s crap that you can’t stop watching.

1 answer
1 view

Description : Can an imac do hdmi in to allow for tv?

Last Answer : I use an eyeTV tuner to hook my cable up to my iMac. Works like a charm. I have an old iMac and I don’t think it has an hdmi connection, but the eyeTV tuner is more than sufficient.

1 answer
0 views

Description : Is there any reason I shouldn't do DISH tv?

Last Answer : Aside from it stealing your soul? No, no reason not to try it. We’ve had DISH for 5 years. We never had any huge issues with it.

1 answer
0 views

Description : Keeping cablebox on constantly for Tivo?

Last Answer : answer:To answer your question, Yes the cable box needs to be on in order to record on your TV, since the cable box needs to decode the channels for you to view and record them. I would recommend ... Cable Card (dual tuner support, one cable card), and it works quite well on Comcast. Good Luck! R

1 answer
0 views

Description : Does anyone subscribe to AT&T U-Verse?

Last Answer : i just signed up for it yesterday and getting it installed on Sunday tv with internet outside of Chicago. Can't say anything about the service if it is good or not, but getting anything installed on the ... is no good, I can cancel with no penalty. Runs on fiber which should be better than dsl.

1 answer
234 views

Description : A cable has inductance of 0.22 mH per kilometer and capacitance of 0.202 µF per kilometer. The surge impedance of the cable is (a) 50 Ω (b) 42 Ω (c) 33 Ω (d) 28 Ω

0 answers
16 views

Description : The minimum dielectric stress in a cable is at (a) armour (b) bedding (c) conductor surface (d) lead sheath

Last Answer : (d) lead sheath

1 answer
38 views

Description : In a cable immediately above metallic sheath _____ is provided. (a) Earthing connection (b) Bedding (c) Armouring (d) None of the above

Last Answer : (b) Bedding

1 answer
14 views

Description : The bedding on a cable consists of (a) Hessian cloth (b) Jute (c) Any of the above (d) None of the above

Last Answer : (c) Any of the above

1 answer
23 views

Description : Which of the following protects a cable against mechanical injury? (a) Bedding (b) Sheath (c) Armouring (d) None of the above

Last Answer : (c) Armouring

1 answer
0 views

Description : What is underground cable ?

Last Answer : An underground cable is one or more field conductors covered by an insulation and protective sheath capable of withstanding the required amount of voltage.

1 answer
108 views

Description : An optical fiber cable laid underground has developed a discontinuity at a distance d from the source end. The fault can be located using the instrument  (a) Optical spectrum Analyzer (OSA) (b) Optical Time Domain Reflectometer (OTDR) (c) Optical Power Meter (OPM) (d) Laser Diffractometer (LD)

Last Answer : An optical fiber cable laid underground has developed a discontinuity at a distance d from the source end. The fault can be located using the instrument Optical Time Domain Reflectometer (OTDR) 

1 answer
437 views

Description : Minimum distance of underground cable from the foundation of building should be   (a) 100 cm (b) 50 cm (c) 10 cm (d) 5 cm 

Last Answer : A

1 answer
470 views

Description : Do you think is DC better than AC to transmit energy?

Last Answer : In Long distance DC transmission will be better in cost. It requires more equipments for flexiblity In short distance AC transmission is better in  cost. It is more Flexible

2 answers
379 views

Description : A long transmission line has considerable ……………….. effect. A) series capacitance B) shunt capacitance C) series inductance D) shunt inductance

Last Answer : Shunt Capacitance. 

2 answers
114 views

Description : A single-line-to-ground fault on a overhead transmission line creates (A) voltage sag (B) voltage swell (C) over voltage (D) voltage flicker 

Last Answer : Creates  overvoltage.

1 answer
421 views

Description : For a transmission line open circuit and short circuit impedances are 20 Ω and 5 Ω. Then characteristic impedance is: (1) 100 Ω (2) 50 Ω (3) 25 Ω (4) 10 Ω

Last Answer : For a transmission line open circuit and short circuit impedances are 20 Ω and 5 Ω. Then characteristic impedance is: 10 Ω

1 answer
...