How the leakage reactance of the transformer is reduced?

1 Answer

Answer :

In transformers the leakage reactance is reduced by interleaving the high voltage and low voltage winding.

Related questions

Description : How is magnetic leakage reduced to a minimum in commercial transformers?

Last Answer : By interleaving the primary and secondary windings.

Description : A single phase transformer has resistance and reactance of 0.2 pu and 0.6 pu respectively. Its pu voltage regulation at 0.8 pf lagging would he

Last Answer : A single phase transformer has resistance and reactance of 0.2 pu and 0.6 pu respectively. Its pu voltage regulation at 0.8 pf lagging would he 0.52

Description : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is (A) 0.85 Ω (B) 3.63 Ω (C) 36.3 Ω (D) 252 Ω

Last Answer : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is 3.63 Ω

Description : 27] In a transformer, the leakage flux of each winding is proportional to the current in that winding because A. Ohm's law applies to magnetic circuits B. Leakage paths do no saturate C. the two windings are electrically isolated D. mutual flux is confined to the core

Last Answer : B. Leakage path do not saturate

Last Answer : The leakage flux in a transformer depends upon load current.

Description : Give equivalent resistance, reactance and impedance referred to secondary circuit.

Last Answer : Req = R2 +R1' = R2+ R1'/a² Xeq = X2 +X1' = X2+ X1'/a² Zeq = Z2 + Z1' = Z2+ Z1'/a² where a=T1/T2

Description : Give equivalent resistance, reactance and impedance referred to primary circuit.

Last Answer : Req = R1 +R2' = R1+a² R2' Xeq = X1 +X2' = X1+a² X2' Zeq = Z1 +Z2' = Z1+a² Z2' where a=T1/T2

Description : 55 When a 400Hz transformer is operated at 50Hz its KVA rating is A. Reduced to 1/8 B. Increased 8 times C. Unaffected D. Increased 64 times

Last Answer : A. Reduced to 1/8

Description : 4] In operating a 400hz transformer at 50Hz A. Only voltage is reduced in the same proportion as the frequency B. Only KVA rating is reduced in the same proportion as the frequency C. Both voltage and KVA rating are reduced in the same proportion as frequency D. None of the above

Last Answer : B. Only KVA rating is reduced in the same proportion as the frequency

Description : 19 Transformer cores are built up from laminations rather than from solid metal so that A. Oil penetrates the core more easily B. Eddy current loss is reduced C. Less lamination is required for the windings D. Turn ratio is higher than voltage ratio

Last Answer : B. Eddy current loss is reduced

Description : 7 The main advantage of auto transformer over a two winding transformer is A. Hysteresis losses are reduced B. Saving in winding material C. Copper losses are negligible D. Eddy losses are totally eliminated

Last Answer : A) hysteresis losses is reduced

Last Answer : When a given transformer is run at its rated voltage but reduced frequency, its core flux density is increased.

Last Answer : Greater the secondary leakage flux less will be the secondary induced e.m.f.

Description : When a megohmmeter is used to test insulation, the gradual rise of the pointer reading as a result of continued cranking, is caused by _____________. A. good conductor resistance B. the ... insulation C. the inductive reactance of the windings D. the dielectric-absorption effect of the insulation

Last Answer : Answer: D

Description : Two transformers operating in parallel will share the load depending upon their (A) Rating. (B) Leakage reactance. (C) Efficiency. (D) Per-unit impedance.

Last Answer : Ans: A Transformers having higher kVA rating will share more load.

Description : What are the transformer losses?

Last Answer : Answer: TRANSFORMER LOSSES - There are mainly two kinds of losses in a transformer namely 1. Copper loss (ohmic loss) and 2.magnetic loss (core loss). Copper losses are caused by the ... ohmic loss the following two losses are also present in the transformer stray load loss and dielectric loss.

Description : At what power maximum efficiency of power transformer and distribution transformer is designed

Last Answer : Maximum efficiency of the transformer is attained at certain load factor (α) when core losses of transformer is equal to the copper losses. PCore loss = α ^2 X PCopper loss From the ... the day. Hence distribution transformers are designed to have maximum efficiency at 50% of the rated full load

Description : What happen when Transformer is given DC supply ?

Last Answer : When DC supply is given to the transformer primary winding no back emf is induced in the transformer. Importance of Back emf is that it limits the current drawn by the machine. In the absence ... in burning down of primary winding. So when dc supply is given to transformer primary windings will burn

Description : During No load why the power factor of the transformer is very low ?

Last Answer : Current flowing through the transformer consists of two components. Magnetizing current (Im) which is in quadrature (90 0 ) to the applied voltage and in phase current which is in phase to the applied voltage ... power factor of transformer during no load condition will by in the order of 0.1 to 0.2

Description : What is the supply rated o/p if two single phase transformer connect to give three phase o/p from a three phase I/p?

Last Answer : A. Each transformer is only capable of supplying 86.6%of its o/p rating

Description : How to connect two single phase transformer to give three phase o/p from a three phase I/p ?

Last Answer : A. They would have to connect in an open-delta.

Description : What is the 3 ph transformer ?

Last Answer : A. A 3ph transformer is that transformer which is equivalent to three single phase transformer but wound on one core and enclosed within one common case.

Description : What parameters or technical particulars are important to be considered while designing protection scheme of the transformer?

Last Answer : 1.Network Diagram showing the position of the transformer in the system 2.kVA or MVA rating of the transformer 3.Fault Level at the transformer 4.Voltage Ratio 5.Winding Connections 6.Per Unit ... Oil Filled 11.Length and area of cross section of the connecting leads between CTs and Relay Panel

Description : What can be the reasons for the failure of the transformer?

Last Answer : Answer: Transformer is one of the most expensive equipments in the Power System. Failure of the transformer can cause outage of power supply for even days. However, multiple things can go wrong with ... relays. 3.Short Circuits 4.Open Circuits 5.Earth Faults 6.Over Voltage 7.Reduced system frequency

Description : How Transformer Protection provided for internal faults?

Last Answer : 1.Bucholz Relay (1st Stage Alarm and 2nd Stage Trip) 2.Sudden Pressure Relay (1st Stage Alarm and 2nd Stage Trip) 3.Pressure Relief Valve (1st Stage Alarm and 2nd Stage Trip) 4.Pressure Switch ... 8.Gas Temperature Indicator (Alarm) 9.Silicon Breather (Passive - no alarm) 10.Smoke Detector (Alarm)

Description : How does change in frequency affect the operation of a given transformer?

Last Answer : a) Iron loss .........increases with a decrease in frequency. A 60-Hz transformer will have nearly 11% higher losses when worked on 50Hz instead of 60 Hz. However, when a 25-Hz ... ....since total loss is greater at a lower frequency, the temperature is increased with decrease in frequency.

Description : Does the transformer draw any current when its secondary is open?

Last Answer : Yes, no-load primary current.

Description : WHAT is ZIG ZAG Grounding Transformer

Last Answer : ANSWER: Three Single Phase Transformers can be connected to have a three phase Zig Zag Transformer. This system can be used for either grounding or developing a fourth WIRE from a three phase neutral. An example ... - three phase - three wire system to a 480Y/277 V - three phase - four wire system

Description : What is Meant by Temperature Rise in a Transformer?

Last Answer : ANSWER: Temperature rise in a transformer is the temper¬ature of the windings and insulation above the existing ambi¬ent or surrounding temperature, and is determined by the insulation class used in the transformer coils.

Description : What is Meant by Regulation in a Transformer?

Last Answer : ANSWER: Voltage regulation in transformers is the difference between the no load voltage and the full load voltage. This is usually expressed in terms of percentage. For example: A transformer delivers 100 ... from 2% to 4%, depending on the size and the application for which they are used

Description : What is Polarity, When Associated With a Transformer?

Last Answer : A: Polarity is the instantaneous voltage obtained from the primary winding in relation to the secondary winding. Transformers 600 volts and below are normally connected in additive polarity - that ... parallel for three phase operations. Polarity is a term used only with single phase transformers

Description : During No load why the power factor of the transformer is very low ?

Last Answer : A. Current flowing through the transformer consists of two components. Magnetizing current (Im) which is in quadrature (900) to the applied voltage and in phase current which is in phase to the applied voltage ... factor of transformer during no load condition will by in the order of 0.1 to 0.2

Description : Explain about auto transformer?

Last Answer : A. It is type of transformer with only one winding a portion of which is shared by both primary and secondary. Advantages: It is used where transformation ratio differs little from unity. As ... voltage as per out requirements and can smoothly increase or decrease its value as per our requirement.

Description : Explain about the open and short circuit tests on transformer?

Last Answer : A. Open circuit test (No load test) and short circuit test (full load test) are performed on a transformer to determine (i) Equivalent circuit of transformer (ii) Voltage ... determine copper loss in transformer at full load and parameters of approximate equivalent circuit of transformer.

Description : EMF equation of the transformer?

Last Answer : A. E = 4.44ΦmfN Volts. If E1 & E2 are primary and secondary emf’s and N1 & N2 are primary and secondary turns then, Voltage ratio= E1/E2 and Turns ratio of transformer = N1/N2 E1/E2 = N1/N2

Description : What is tertiary winding? What is Three Winding Transformer? What are its advantages?

Last Answer : A. In some high rating transformers, one winding, in addition to the primary and secondary winding, is used. This is known as Tertiary Winding of Transformer. Because of this third winding, the ... it assists in limitation of fault current in the event of a short circuit from line to neutral.

Description : What is polarity, when associated with a transformer?

Last Answer : A. Polarity is the instantaneous voltage obtained from the primary winding in relation to the secondary winding. Transformers 600 volts and below are normally connected in additive polarity - that ... parallel for three phase operations. Polarity is a term used only with single phase transformers.

Description : Can a Single Phase Transformer be used on a Three Phase source?

Last Answer : A. Any single phase transformer can be used on a three phase source by connecting the primary leads to any two wires of a three phase system, regardless of whether the source is three phase 3-wire or three phase 4 wire. The transformer output will be single phase.

Description : What is meant by regulation in a transformer?

Last Answer : A. Voltage regulation in transformers is the difference between the no load voltage and the full load voltage. This is usually expressed in terms of percentage. Example: A Transformer delivers 100 ... The regulation capacity varies depending on the size and the application for which they are used.

Description : What will happen if DC supply is given on the primary of a transformer?

Last Answer : A. Mainly transformer has high inductance and low resistance. In case of DC supply there is no inductance, only resistance will act in the electrical circuit. So, high electrical current will flow through primary side of the transformer. Due to this the coil and insulation will burn out.

Description : Explain the operation of variable frequency transformer?

Last Answer : A. A variable frequency transformer is used to transmit electricity between two asynchronous alternating current domains. It is a double fed electric machine resembling a vertical shaft hydroelectric ... adjustable phase shifting transformer. It allows control of the power flow between two networks.

Description : What is voltage ratio of a transformer?

Last Answer : A. Voltage ratio is the ratio of the voltage between the line terminals of one winding to that between the line terminals of another winding at no load.

Description : If we give 2334 A, 540V on Primary side of 1.125 MVA step up transformer, then what will be the Secondary Current, If Secondary Voltage=11 KV?

Last Answer : A. As we know the Voltage & current relation for transformer-V1/V2 = I2/I1 We Know, VI= 540 V; V2=11KV or 11000 V; I1= 2334 Amps. By putting these value on Relation540/11000= I2/2334 So,I2 = 114.5 Amps

Description : What is the function of transformer oil?

Last Answer : A. Transformer Oil serves mainly two purposes 1. It acts as liquid insulation in electrical power transformer 2. It dissipates heat of the transformer i.e acts as coolant. In addition to these ... acid (C7, C8) esters are also becoming increasingly common as alternatives to naphthenic mineral oil.

Description : What is the difference between delta-delta, delta-star transformer?

Last Answer : A. Delta-delta transformer is used at generating station or a receiving station for Change of Voltage (i,e) generally it is used where the Voltage is high & Current is low whereas Delta-star ... star neutral is taken as a return path and this configuration is used for Step down voltage phenomena.

Description : What current flows in the transformer primary when its secondary is open?

Last Answer : A. When the secondary is open, there is no current in the secondary of the transformer. The primary takes a small current I0) from the source called no-load current which has a magnetizing ... ) producing the magnetic flux and a working component (I0 cosθ0) supplying real power for iron losses.

Description : Explain about the losses in Transformer?

Last Answer : TRANSFORMER LOSSES - Transformer losses have two sourcescopper loss and magnetic loss. Copper losses are caused by the resistance of the wire (I2R). Magnetic losses are caused by eddy currents ... current. Eddy-current loss, however, is different for each frequency passed through the transformer.

Description : What is an ideal transformer?

Last Answer : A. Transformer having an overall efficiency of 100 per cent is called an ideal transformer.

Description : In a Tap changing transformer on which side is the tap connected, primary side or secondary side?

Last Answer : A. Tapings are always connected to high voltage winding side, because of low current. If we connect tapings to low voltage side, sparks will produce while tap changing operation due to high current.

Description : What is an isolation transformer?

Last Answer : A. An isolation transformer also referred to as insulating transformer, is one where the primary and secondary windings are separate.