A switchboard for an AC electrical system requires the use of which of the following devices? A. Frequency meter. B. Ohmmeter.  C. Induction voltage regulator. D. Current transformer governor.

1 Answer

Answer :

Answer: A

Related questions

Description : The frequency of an alternator is controlled from the main switchboard by adjusting the _____________. A. frequency meter B. voltage regulator C. governor control D. sychroscope switch

Last Answer : Answer: C

Description : In the illustration, the component labeled 'EXC' is _______. EL-0003 A. a separate class II regulated DC generator for critical direct current loads B. a generator feeding the FLD ... to drive the governor for turbogenerator speed. D. the electronic driver for the switchboard metering circuits

Last Answer : Answer: B

Description : A switchboard, for a AC electrical distribution system, will be provided with which of the following components? A. Frequency meter. B. Ammeter C. Voltmeter D. All of the above

Last Answer : Answer: D

Description : The device labeled 'REG SW' in the illustration is used to ___________. EL-0003 A. shift from the automatic voltage regulator to the manual voltage regulator B. shift the governor control from manual to ... device 'REG ADJ' or device 'MAN ADJ' D. supply regulated control power to the switchboard

Last Answer : Answer: A

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : When paralleling two AC generators, the frequency of the incoming machine immediately prior to closing its breaker should be ____________. A. controlled by placing the governor switch in the automatic ... regulator C. slightly greater than the bus frequency D. slightly less than the bus frequency

Last Answer : Answer: C

Description : Equal power factors on paralleled AC generators are maintained by an automatic _____________. A. voltage regulator B. reverse power relay C. reverse current relay D. governor control switch

Last Answer : Answer: A

Description : A constant output voltage from an AC generator is maintained by the _____________. A. prime mover governor B. exciter generator C. voltage regulator D. reverse power relay

Last Answer : Answer: C

Description : A current carrying conductor making an electrical contact with a wiring metal conduit is indicated by a _____________. A. low switchboard wattmeter reading B. reading of 1.0 on the power factor meter C. high switchboard voltmeter reading D. totally darkened switchboard ground-detecting light

Last Answer : Answer: D

Description : The part of the shipboard electrical system used to control the distribution of power to the branch circuits, is the _____________. A. bridge control panel B. disconnect links C. governor relay box D. main switchboard

Last Answer : Answer: D

Description : A transformer in an electric circuit serves to ____________. A. generate its own electrical power B. transform electrical energy into mechanical energy C. increase or decrease circuit voltage as required D. convert AC current to DC current

Last Answer : Answer: C

Description : On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. To check this insulation with the machine assembled you should use a____________. A. millivolt meter and a jumper B. ohmmeter C. megohm meter D. high potential tester

Last Answer : Answer: A

Description : On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. To check this insulation with the machine assembled you should use a____________. A. ohmmeter with the ... C. megohm meter with the machine running D. voltmeter and ampmeter with the machine running

Last Answer : Answer: B

Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators

Last Answer : Answer: D

Description : Which of the meters listed should only be used after a circuit has been electrically disconnected? A. Wattmeter B. Frequency meter C. Ammeter D. Ohmmeter

Last Answer : Answer: D

Description : The cycles per second developed by the alternator aboard your vessel is determined by _____________. A. the speed of the engine driving the alternator B. the resistance applied to the field rheostat C. the synchronous speed of induction D. the adjustments made to the voltage regulator

Last Answer : Answer: A

Description : A current-carrying conductor making electrical contact with a wiring conduit will be indicated by a _____________. A. high switchboard wattmeter reading B. totally dark switchboard ground detecting light C. low switchboard wattmeter reading D. all of the above

Last Answer : Answer: B

Description : The basic meter movement responds to the flow of current through its coil. Therefore, this meter movement may be used as a/an _____________. A. voltmeter by placing a resistance in parallel with the ... in parallel with the coil D. ammeter by placing a low resistance in parallel with the coil

Last Answer : Answer: D

Description : The voltage developed by an AC generator is controlled by varying the ____________. A. speed of the prime mover B. AC excitation to the field C. DC excitation to the field D. DC excitation of the voltage regulator

Last Answer : Answer: C

Description : When securing an AC generator, you should FIRST ___________. A. open the generator circuit breaker B. switch the voltage regulator to 'manual' C. decrease the field excitation to minimum D. reduce the load on the unit

Last Answer : Answer: D

Description : Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the __________. A. manual position B. bus neutral position C. raise voltage position D. transfer position

Last Answer : Answer: A

Description : The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ____________. A. droop B. drop C. dip D. regulation

Last Answer : Answer: C

Description : Section II of the circuit shown in the illustration is the ____________. EL-0085 A. voltage regulator B. filter C. rectifier D. voltage transformer

Last Answer : Answer: C

Description : Section IV of the circuit shown in the illustration is the _____________. EL-0085 A. voltage regulator B. filter C. rectifier D. voltage transformer

Last Answer : Answer: A

Description : Section III of the circuit shown in the illustration is a _____________. EL-0085 A. voltage regulator B. filter C. rectifier D. voltage transformer

Last Answer : Answer: B

Description : If reading AC current with the illustrated device and unsure of the range as a precaution , the first step should be to _________. EL-0047 A. secure power and test for voltage B. disconnect the ... resistance and use Ohm's law to calculate current D. unable to safely measure current with the device

Last Answer : Answer: A

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D

Description : A three-phase alternator is developing 300 amps, with a 0.8 power factor, at 450 volts. The true indicated power on the kilowatt meter, located on the main switchboard, will be ____________. A. 133 kw B. 155 kw C. 187 kw D. 212 kw

Last Answer : Answer: C

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter would then read ____________. A. 181.4 KW B. 186.8 KW C. 194.2 KW D. 201.4 KW

Last Answer : Answer: B

Description : A switchboard ammeter indicates a reading slightly above 'zero' when the leads are disconnected, this is caused by _____________. A. mechanical misalignment of the meter pointer B. a poor ground for the meter case C. static electricity in the air D. capacitors inside the meter storing charges

Last Answer : Answer: A

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter reading would increase by ___ A. 17.8 KW B. 23.2 KW C. 30.6 KW D. 37.8 KW

Last Answer : Answer: B

Description : Two AC generators of the same capacity are operating in parallel. One with a zero speed droop setting and the other with a 5% speed droop. If its capacity is not exceeded, the unit whose ... B. maintain the frequency of the system C. have poor sensitivity characteristics D. have poor power response

Last Answer : Answer: B

Description : A ground is indicated by the ground-detecting system on the main electrical switchboard. The FIRST step in locating the actual ground is to _____________. A. close all circuit breakers in ... ground detection system indicates normal C. change over generators D. check each circuit with a megohmmeter

Last Answer : Answer: B

Description : Which of the following statements is true concerning a stepdown transformer in an operating AC power circuit? A. Voltage and current will both be increased. B. Voltage and current will both be decreased C. Voltage decreases as current increases. D. Voltage increases as current decreases.

Last Answer : Answer: C

Description : An ohmmeter can be used to measure ____________. A. current flow in a circuit B. voltage between two points in a circuit C. circuit continuity D. power

Last Answer : Answer: C

Description : The speed of a series wound winch motor is controlled by ____________. A. varying the voltage applied to the motor B. the weight of the load on the cargo boom C. overcurrent protection devices in the motor D. a hydraulic speed-limiting governor

Last Answer : Answer: A

Description : The electrical supply applied to the anodes shown in the illustration is _____________. EL-0090 A. low voltage, high current DC B. low voltage, high current AC C. high voltage, low current DC D. high voltage, low current AC

Last Answer : Answer: A

Description : The frequency of an AC generator is controlled by the _____________. A. rheostat B. governor C. exciter D. capacitor

Last Answer : Answer: B

Description : The frequency of an AC generator is adjusted by means of the ____________. A. main alternator field rheostat B. exciter field rheostat C. prime mover governor control D. equalizing reactor

Last Answer : Answer: C

Description : Before any work on electrical or electronic equipment is performed, which of the following precautions should be carried out? A. De-energize the applicable switchboard bus. B. Bypass the interlocks. C. ... supply circuit breaker in the open position. D. Station a man at the circuit supply switch.

Last Answer : Answer: C

Description : Which of the following should be the FIRST step in removing a generator from parallel operation? A. Trip the generator off the switchboard. B. Turn off all electrical equipment. C. Remove the load from the 'off going' generator. D. Increase the cycles of the generator staying on the line.

Last Answer : Answer: C

Description : A ground in an electrical circuit outside the engine room _____________. A. cannot be detected under normal conditions B. is of no consequence to engineering personnel C. is indicated at the branch circuit breaker panel D. is indicated by the ground detecting lamps on the main switchboard

Last Answer : Answer: D

Description : The electrical energy necessary to power a sound-powered telephone's small vibrating bell is obtained from _________. A. the emergency batteries for the general alarm B. each station's hand-cranked generator C. the emergency switchboard D. normal 115 volt DC supplies

Last Answer : Answer: B

Description : The electrical energy necessary to transmit a person's voice over a sound-powered telephone circuit is obtained from _____________. A. dry cell batteries B. the ship's service switchboard C. the emergency switchboard D. the speaker's voice

Last Answer : Answer: D

Description : The voltage of an operating AC turbogenerator is raised or lowered by adjusting the _____________. A. exciter generator governor controls B. synchronizing switch C. phase sequence switch D. generator field exciter

Last Answer : Answer: D

Description : Kilowatt load is divided between two AC generators operating in parallel by _____________. A. adjusting the governor controls B. varying the excitation voltage C. increasing both prime mover speeds simultaneously D. decreasing both prime mover speeds simultaneously

Last Answer : Answer: A