Most three-phase induction motors of five horsepower or less, are started by _____________. A. autotransformer starters B. resistor starters C. across-the-line starters D. reactor starters

1 Answer

Answer :

Answer: C

Related questions

Description : Low horsepower, polyphase, induction motors can be started with full voltage by means of _____________. A. compensator starters B. autotransformer starters C. across-the-line starters D. primary-resistor starters

Last Answer : Answer: C

Description : Most three-phase induction motors used for driving engine room auxiliaries are started by _____________. A. resistor starters B. across-the-line starters C. impedance starters D. reactor starters

Last Answer : Answer: B

Description : In general, polyphase induction motors can be started on full line voltage by means of ______________. A. compensator starters B. autotransformer starters C. across-the-line starters D. primary-resistor starters

Last Answer : Answer: C

Description : Autotransformer starters or compensators are sometimes used with polyphase induction motors to _____________. A. reduce the voltage applied to the motor during the starting period B. increase the voltage for ' ... to be either stepped up or down, depending on the application, to ensure full torque

Last Answer : Answer: A

Description : Which of the listed types of motor controllers and starters is illustrated? EL-0080 A. Across-the-line B. Primary-resistor C. Autotransformer D. Part-winding

Last Answer : Answer: C

Description : Across-the-line starters are used with AC motors to provide _____________. A. reduced starting current B. regulated starting current C. high starting torque D. controlled starting acceleration

Last Answer : Answer: C

Description : As shown in the illustration, which of the listed types of motor controllers and starters is indicated? EL-0012 A. Across-the-line B. Capacitor C. Autotransformer D. Part-winding

Last Answer : Answer: C

Description : An advantage of DC motors over AC motors is that they _____________. A. are less expensive B. require less maintenance C. can be started across the line D. offer a more effective means of controlling speed

Last Answer : Answer: D

Description : The electrical schematic shown in the illustration represents a/an ____________. EL-0017 A. across-the-line starter B. primary-resistor starter C. autotransformer starter D. part-winding starter

Last Answer : Answer: A

Description : The function of the autotransformers used with the starters of large AC motors is to provide _____________. A. increased voltage for starting B. increased torque for starting C. reduced voltage for starting D. speed control

Last Answer : Answer: C

Description : The voltage at the reference electrode of the circuit shown in the illustration is applied to the input of a/an ______________. EL-0090 A. class A detector whose output drives an ... drives an 2-stage isolation transformer D. magnetic amplifier whose output controls a saturable reactor

Last Answer : Answer: D

Description : The air gap provided in induction motors should be checked periodically with a feeler gage to detect an unequal air gap and _____________. A. decreased motor magnetizing current B. hysteresis loses C. increased power factor D. mechanical damage to the rotor

Last Answer : Answer: D

Description : The rotation of a three-phase induction motor can be reversed by _____________. A. interchanging any two of the three line leads to the stator B. disconnecting one of the three line leads to the ... the shunt field coil leads D. permanently disconnecting any two of the three line leads to the stator

Last Answer : Answer: A

Description : Which of the following is a characteristic of fractional horsepower repulsion start motors? A. They start with a rotating stator field. B. The short circuiting ring is removed from the commutator while ... brushes are removed from the commutator while starting. D. They have a low starting torque.

Last Answer : Answer: B

Description : The electrical schematic illustrated in figure A, depicts a/an _____________. EL-0059 A. autotransformer B. Delta Wye transformer C. primary EMF generator D. potential transformer

Last Answer : Answer: D

Description : The diagram shown in the illustration represents a/an _____________. EL-0082 A. stepup transformer B. magnetic amplifier C. autotransformer D. Scott-connected transformer

Last Answer : Answer: A

Description : To check the three line fuses of a three-phase system consisting of a three-phase motor, you must _____________. A. place the starter in the 'stop' position B. make sure the motor is operating at full ... leads across the 'hot' ends of the fuses D. place the leads across the bottom ends of the fuses

Last Answer : Answer: A

Description : Why are centrifugal switches provided on many 1-phase Induction motors?

Last Answer : Centrifugal switches are provided on many 1-phase Induction motors to disconnect the starting / auxiliary winding from the supply when the motor reaches about 70% of its synchronous speed.

Description : Name types of 1-phase induction motors.

Last Answer : Based on the method of starting arrangement provided, the 1-phase Induction motors are classified as follows (i) Split-phase motor (ii) Shaded pole motor (iii) Resistor start Induction run ... iv) capacitor start Induction run single phase IM (v) capacitor start Capacitor run single phase IM

Description : Name the two different theories with which principle of 1-phase induction motors are explained

Last Answer : The two different theories are · Double revolving field theory · Cross field theory

Description : Where do we require single-phase induction motors?

Last Answer : Single-phase induction motors are required where (i) 3 phase supply is not available (ii) Efficiency is of lesser importance (iii) Rating is less than one H.P. (iv) Equipment is portable

Description : What are the types starters used for starting of induction motor?

Last Answer : a. Direct on line starter (air break) mechanically. b. Direct on line starter (air break or oil immersed) electrically. c. Star delta starter. d. Slipring motor starter. e. Auto transformer starter.

Description : A single-phase induction motor fails to start. The rotor is spun rapidly with the line switch closed. Having started by this method it is noted that the motor fluctuates between a very slow ... lies in the ______ A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload

Last Answer : Answer: A

Description : Draw the power and control circuit for motors using autotransformer type starter.

Last Answer : Draw the power and control circuit for motors using autotransformer type starter.

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : A three-phase, squirrel cage, induction motor will run hot due to _____________. A. open stator coils B. high power factor C. dirty or corroded slip rings D. reversed commutating poles

Last Answer : Answer: A

Description : In a three-phase, squirrel-cage type, induction motor the rotating magnetic field is established by the _____________. A. current induced in the rotor windings B. application of a three-phase voltage ... caused by the induced current in the squirrel-cage bars with the magnetic field of the stator

Last Answer : Answer: B

Description : The speed of a three-phase squirrel-cage induction-type motor operating in a fixed frequency system is varied by changing the _____________. A. number of phases to the motor B. number of stator poles C. locked rotor current D. resistance of the rotor winding

Last Answer : Answer: B

Description : One horsepower is equal to _____________. A. 500 watts B. 663 watts C. 746 watts D. 1,000 watts

Last Answer : Answer: C

Description : A four pole, 60 Hz, three-phase synchronous motor comes up to 1760 RPM when started as an induction motor. What is the percent slip after the rotor field is energized? A. 0 B. 1.1 C. 2.2 D. 3.3

Last Answer : Answer: A

Description : An advantage of DC motors over AC motors is that they _____________. A. are less expensive B. require less maintenance C. offer infinite speed variation D. all of the above

Last Answer : Answer: C

Description : Which ofthe following materials is used in the manufacture of resistance grids to be used in the starters of large motors ? (a) Copper (b) Aluminium (c) Steel (d) Cast-iron

Last Answer : (d) Cast-iron

Last Answer : Starters are used with D.C. motors because to restrict armature current as there is no back e.m.f. while starting.

Description : THREE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. Insertion of resistance in the stator of an induction motor (a) increases the load torque (b) decreases the starting torque (c) increases the starting torque (d) none of the above Ans: b

Description : Deep bar rotor construction is used in three phase induction motors to mainly: (1) Control speed (2) Control power factor (3) Increase starting torque (4) None of these

Last Answer : Deep bar rotor construction is used in three phase induction motors to mainly: Increase starting torque

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the main winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the run winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to _____________. A. a faulty centrifugal switch B. broken rotor bars C. worn bearings D. all of the above

Last Answer : Answer: D

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : The speed of a multi-speed, squirrel-cage, induction motor operating in a fixed frequency system can be changed by _____________. A. reconnecting stator windings for different numbers of poles B. ... sequence of the applied voltage D. reconnecting the stator so that no poles have the same polarity

Last Answer : Answer: A

Description : How do I compare the horsepower ratings of inboard vs. outboard motors - is one kind more powerful?

Last Answer : Inboard engines are quieter and are normally more powerful than outboard motors. Outboards are normally less exspensive and easier to maintain.

Last Answer : Most of the fractional horsepower motors have either plain or sleeve bearings.

Description : An across-the-line starter is typically used for which of the following applications? A. Reduced-current starting of large motors B. Low torque starting of small motors C. Low resistance starting of DC motors D. Full-voltage starting of motors

Last Answer : Answer: D

Description : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the ... load torque is approximately equal to (A) 0.24 (B) 1.44 (C) 2.40 (D) 6.00

Last Answer : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the starting developed torque to the full load torque is approximately equal to 1.44

Description : A series wound DC motor has its armature and field connected in series with a resistor. When the motor is disconnected from its power supply, this motor will exemplify __________. A. the ... the proper connections for an automatic strip heater C. a reversing controller circuit D. dynamic braking

Last Answer : Answer: D

Description : State with neat sketch the construction of three phase autotransformer.

Last Answer : Operation: Working principle is based on self-induction. When three-phase ac supply is given to star connected three windings, flux is produced and gets linked with each phase winding. The emf ... . Depending upon the position of variable terminal, we get variable AC voltage at the output.

Description : Why Is The Efficiency Of A Three-phase Induction Motor Is Less Than That Of A Three-phase transformer ?

Last Answer : Three phase Induction motor is nothing but a rotating transformer . Due to rotating nature, there are friction and windage losses associated with it. On the other hand, the three-phase transformer is ... the efficiency of three-phase induction motor is less than that of a three-phase transformer .

Description : How do split-phase induction motors become self-starting?

Last Answer : By using combinations of inductance and capacitance to apply out-of phase currents in starting windings.