Which sensor shown in the illustration develops its own conditioning and point setting and 'reports' directly to the 'annunciator'? EL-0094 A. Transducer B. Resistance Temperature Detector (RTD) C. Pressure Switch D. Thermocouple

1 Answer

Answer :

Answer: C

Related questions

Description : The sensor connected to 'signal conditioner' (6000F125) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: B

Description : The sensor connected to 'signal conditioner' (6000AH170) shown in the illustration is a/an _____________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: A

Description : The sensor connected to 'signal conditioner' (6000F085) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: D

Description : An open-circuit fault between the pressure switch and the 'annunciator module' shown in the illustration would cause the alarm circuit to react in the same manner as if ___________. EL-0094 A. 3.5 ... below switch setting C. 50 PSI were applied to the 'setpoint module' D. the pressure switch closed

Last Answer : Answer: B

Description : The +5 volt regulated power supply shown in the illustration is fed directly from the _______________. EL-0094 A. 115 volt AC bus B. Annunciator Module C. +24 volt supply D. Annunciator Controller

Last Answer : Answer: C

Description : What is the purpose of either 'setpoint module' (6000F090/030) shown in the illustration? EL-0094 A. Program the 'signal conditioner' as to how to vary its input. B. Supply 0 - 10 volts to ... . Obtain an input from the 'signal conditioner' and, if outside set limits, signals the 'annunciator'.

Last Answer : Answer: D

Description : What is the purpose of the 'annunciator module' (6000F35) shown in the illustration? EL-0094 A. Provide an input to the setpoint module. B. Drive the alarm lamp and, through the controller, the horn. ... and +24 volts to their respective power supplies. D. Connect 24 volts to both sides of the horn.

Last Answer : Answer: B

Description : What type of service is NOT provided by the circuit shown in the illustration? EL-0094 A. Logging of engine order signals from the bridge. B. Printed record of alarms as they ... . Visual metering of temperature and pressure conditions. D. Periodic recording of pressure and temperature conditions.

Last Answer : Answer: A

Description : As shown in the illustration, which set of conditions, evident to the operator and the 'setpoint module' respectively, will result in a high exhaust temperature alarm on the 'starboard main engine'? EL-0094 A. 50°F and 3.3 volts B. 180°F and 6.0 volts C. 750°F and 0-10 volts D. 900°F and 7.5 volts

Last Answer : Answer: D

Description : Which plant parameters shown in the illustration would produce an alarm if they exceeded preset values? EL-0094 A. SME #7 CYL. EXH. and L.O. TO RDCN. GR. B. L.O. PRESS. TO MN. ENG. and PME #3 MN. BRG. C. L.O. PRESS. TO MN. ENG. and L.O. TO RDCN. GR. D. PME #3 MN. BRG. and SME #7 CYL. EXH.

Last Answer : Answer: D

Description : Which plant parameters shown in the illustration would produce an alarm if they fell below preset values? EL-0094 A. SME #7 CYL. EXH. and L.O. PRESS. TO RDCN. GR. B. L.O. PRESS TO MN. ENG. and PME #3 MN. BRG. C. ... . TO MN. ENG and L.O. PRESS. TO RDCN. GR. D. PME #3 MN. BRG. and SME #7 CYL. EXH.

Last Answer : Answer: C

Description : How many different D.C. voltages are required to operate the circuit shown in the illustration? EL-0094 A. Two B. Three C. Four D. Five

Last Answer : Answer: C

Description : What is resistance temperature detector (RTD) and mention some examples?

Last Answer : Resistance temperature detector is an instrument, which is used to measure temperature. This uses the property that the resistance of a metal changes (increases of decreases) with temperature. This ... calibrated to measure temperature. Different types of RTD's are Platinum, copper, nickel.  

Description : The purpose of the 'heater resistors' for the winch circuit shown in the illustration is to _______________. EL-0102 A. limit the current in the heater circuit B. dispel moisture in the ' ... panel C. keep the winch brake housing below the dew point D. maintain winch motor operating temperature

Last Answer : Answer: B

Description : As the ahead valve opens as shown in the illustration, pin #5 of the Sensor ______________. EL-0099 A. becomes more negative B. becomes more positive C. approaches neutral point D. approaches ground potential

Last Answer : Answer: B

Description : The voltage at the reference electrode of the circuit shown in the illustration is applied to the input of a/an ______________. EL-0090 A. class A detector whose output drives an ... drives an 2-stage isolation transformer D. magnetic amplifier whose output controls a saturable reactor

Last Answer : Answer: D

Description : The purpose of the bias winding in figure 'B' shown in the illustration is for ____________. EL-0091 A. changing the direction of current in the control winding B. setting the operating point of the ... use of either AC or DC in the load circuit D. changing the direction of current through the load

Last Answer : Answer: B

Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs

Last Answer : Answer: B

Description : Which of the listed conditions occur when '4th point lower' is selected on the winch shown in the illustration? EL-0102 A. Master switch contacts '3', '4', '6', '8', '9', & '10' close. B. Contactors '2, 3, & 4M' and ' ... , '7', '8', and '9' close. D. Contactors '1 & 3M' and '1, 2, & 3A' pick up.

Last Answer : Answer: B

Description : Which of the listed conditions occur when selection is made for 'third point hoist' on the winch shown in the illustration? EL-0102 A. Master switch contacts '5', '6', '7', '8', and '9' close. B. Contactors '2M', ' ... ' and '2A' drop out. D. Master switch contacts '3','4', '6', '8', and '9' close.

Last Answer : Answer: D

Description : The only point in the steering stand shown in the illustration which needs periodic lubrication is the ______________. EL-0098 A. repeater assembly ball bearings B. steering wheel bearing C. operation selector switch D. course selector pointer

Last Answer : Answer: B

Description : Pin #8 of the astern valve position sensor shown in the illustration is connected _______________. EL-0099 A. to analog common B. in series with PCOM C. to (-) 50 volts D.C. D. to (+) 50 volts D.C.

Last Answer : Answer: A

Description : Pin #6 of the ahead valve position sensor as shown in the illustration is connected _______________. EL-0099 A. to (-) 50 volts D.C. B. in parallel with PCOM C. to (+) 50 volts D.C. D. to analog common

Last Answer : Answer: C

Description : Describe construction and working of Resistance Temperature Detector (RTD).

Last Answer : RTD:  Construction and working: Resistance thermometer bulbs consist of a coil of fine wire wound or in a frame of insulating material. The resistance wire itself must be homogeneous in order to ... surrounding it. Thus RTD is used to measure temperature in terms of change in resistance.

Description : As shown in the illustration, the circuit which 'shapes' the linear output of the thrust lever so that the steady-state ship speed is linear with respect to that lever's setting is the _____________. EL-0095 A. 'pitch controller' B. 'error amplifier' C. 'function generator' D. 'servo amplifier'

Last Answer : Answer: C

Description : As shown in the illustration, the symbol is used in electrical drawings to designate a ____________. EL-0026 A. limit switch with one set of normally open contacts B. maintaining type ... type push button with a mechanical interlock D. normally closed contact held open mechanically by an interlock

Last Answer : Answer: C

Description : Which of the devices shown in the illustration automatically prevents the simultaneous operation of the windlass from both master switches? EL-0073 A. Selector switch B. Contact 'CR1a' C. Contact 'CR2a' D. Contact 'CR1D'

Last Answer : Answer: D

Description : As shown in the illustration, which listed action will occur first when push button 'Q' is depressed? EL-0017 A. Contacts 'H-1', 'H-2' and 'H-3' close. B. Contact 'H-4' closes. C. Operating coil 'C' energizes. D. Switch 'R' opens.

Last Answer : Answer: C

Description : As shown in the illustration, the function of the switch labeled 'PFSW' is to determine the ______________. EL-0003 A. bus frequency B. reactive volt amperes of the bus C. frequency of either generator D. power factor of either generator

Last Answer : Answer: D

Description : As shown in the illustration, 'B' is a ____________. EL-0058 A. single-pole, double-throw switch B. double-pole, single-throw switch C. double-pole, double-throw switch D. circuit breaker

Last Answer : Answer: C

Description : When reading AC current with the multimeter shown in the illustration and you are unsure of the range, the range switch should be set to ___________. EL-0047 A. 10 MA/ 10 AMP with leads in the (-10 A ... leads in the (-COMMON) and (+10 A) jacks D. unable to measure AC current with this multimeter

Last Answer : Answer: D

Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : When the master switch for the winch shown in the illustration is in the 'off' position, and the line & safe switches are closed, which of the listed relays should be energized? EL-0102 A. 'DB' & '2T' B. 'DB' & '4M' C. 'FR-B.O.' & 'LV' D. '1M' & '1A'

Last Answer : Answer: C

Description : When the operating handle is in the 'off' position, which master switch contacts for the winch shown in the illustration are closed? EL-0102 A. 'MS-DB & OL' B. 'MS-3, 5, 6, 7, & 8' C. 'MS-LVa & OL' D. 'MS-3, 7 & Reset'

Last Answer : Answer: D

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : The small circular symbols to which wire '52N57E' is connected at coordinates '57L' and '57P' shown in the illustration represent ___________________. EL-0100 A. relay contact solder points B. wire wrap connections C. terminal board screws D. switch contact terminals

Last Answer : Answer: C

Description : The heaters for the winch circuit shown in the illustration are powered from _____________. EL-0102 A. a separate source B. the winch main bus C. the master switch power circuit D. the contactor control circuit

Last Answer : Answer: A

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'TEST' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: B

Description : As shown in the illustration, operating the reversing switch will change the polarity of the ______________. EL-0101 A. generator field B. generator armature C. motor armature D. all of the above

Last Answer : Answer: D

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'OFF' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed

Last Answer : Answer: A

Description : The 'reset' contacts of the master switch shown in the illustration provides the winch controller with ___________. EL-0102 A. low voltage release B. overload protection C. low voltage protection D. high power factor correction

Last Answer : Answer: C

Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller

Last Answer : Answer: B

Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'ON' position, contacts '3,4' and '7,8' are respectively ______________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed