Which of the following operating characteristics for DC motors is considered to give high starting torque? A. series B. shunt C. cumulative-compound D. differential-compound

1 Answer

Answer :

Answer: A

Related questions

Description : As compared to shunt and compound DC motors, the series DC motor will have the highest torque because of its comparatively ____________ at the start. (A) Lower armature resistance. (B) Stronger series field. (C) Fewer series turns. (D) Larger armature current.

Last Answer : (D) Larger armature current.

Description : Regenerative braking (A) Can be used for stopping a motor. (B) Cannot be easily applied to DC series motors. (C) Can be easily applied to DC shunt motors (D) Cannot be used when motor load has overhauling characteristics.

Last Answer : Ans: B Because reversal of Ia would also mean reversal of field and hence of Eb

Description : Shunt, series, and compound wound motors, are all DC motors designed to operate from _____________. A. constant potential, variable current DC sources B. variable potential, constant current DC ... C. variable potential, variable current DC sources D. constant potential, constant current DC sources

Last Answer : Answer: A

Description : The speed-torque characteristics of a DC series motor are approximately similar to those of the _________motor. (A) universal (B) synchronous (C) DC shunt (D) two-phase

Last Answer : Ans: A Universal motor has same characteristics as DC series motor and also known as an a.c series motor.

Description : As compared to shunt and compound motors, series motor has the highest torque because of its comparatively .......... at the start.

Last Answer : As compared to shunt and compound motors, series motor has the highest torque because of its comparatively stronger series field at the start.

Description : Which of the methods listed is used to maintain the division of load between two compound-wound, DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt ... generators are connected in series. D. The equalizer connection parallels the series fields of all machines.

Last Answer : Answer: D

Description : Which of the methods listed is used to maintain equal load sharing between two compound wound DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt field rheostats ... are connected in series. D. The series fields of both generators are connected in parallel.

Last Answer : Answer: D

Description : What is the function of the interpoles installed in DC motors? A. To provide greater torque by strengthening the main field. B. To provide sparkless commutation without having to shift the brushes. C. To limit the production of counter-electromotive force. D. To limit the starting surge current.

Last Answer : Answer: B

Description : An across-the-line starter is typically used for which of the following applications? A. Reduced-current starting of large motors B. Low torque starting of small motors C. Low resistance starting of DC motors D. Full-voltage starting of motors

Last Answer : Answer: D

Description : Which of the following types of DC motors has its field connected in parallel with its armature? A. Counter EMF B. Shunt C. Salient pole D. Series

Last Answer : Answer: B

Description : The torque, in a _____________is proportional to the square of the armature current (A) DC shunt motor (B) stepper motor (C) 2-phase servomotor (D) DC series motor

Last Answer : (D) DC series motor

Description : As shown in the illustration, the electrical symbol is used to indicate which of the listed types of motors? EL-0054 A. Shunt motor. B. Series motor. C. Compound motor. D. Tri-field motor.

Last Answer : Answer: C

Description : A cumulative dc compound motor runs at 1500 rpm. on full load. If its series field is short-circuited, its speed  (1) becomes zero (2) remains unchanged (3) increases (4) decreases

Last Answer : Increases. As it's cumulative compound motor, both series and shunt field both assist each other. If series field is short circuited, the overall field strength will decrease and atop of that ... speed is inversely proportional to field strength.  So, the speed will increase overall.

Description : Across-the-line starters are used with AC motors to provide _____________. A. reduced starting current B. regulated starting current C. high starting torque D. controlled starting acceleration

Last Answer : Answer: C

Description : Why do we use capacitor-start induction motors in applications requiring high starting torque in preference to repulsion induction motors?

Last Answer : Capacitors are easily available, cheaper and reliable. Repulsion-induction motors posses a special commutator and brushes that require maintenance. Most manufacturers have stopped making them.

Description : Why do we use capacitor-start induction motors in applications requiring high starting torque in preference to repulsion induction motors?

Last Answer : Ans : Capacitors are easily available, cheaper and reliable. Repulsion-induction motors posses a special commutator and brushes that require maintenance. Most manufacturers have stopped making them.

Description : A variable shunt, connected across the series field coils of a DC compound wound generator, to permit adjustment of the degree of compounding, is called a _____________. A. divider B. diverter C. converter D. rheostat

Last Answer : Answer: B

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : Which of the following is a characteristic of fractional horsepower repulsion start motors? A. They start with a rotating stator field. B. The short circuiting ring is removed from the commutator while ... brushes are removed from the commutator while starting. D. They have a low starting torque.

Last Answer : Answer: B

Description : The function of the autotransformers used with the starters of large AC motors is to provide _____________. A. increased voltage for starting B. increased torque for starting C. reduced voltage for starting D. speed control

Last Answer : Answer: C

Description : Autotransformer starters or compensators are sometimes used with polyphase induction motors to _____________. A. reduce the voltage applied to the motor during the starting period B. increase the voltage for ' ... to be either stepped up or down, depending on the application, to ensure full torque

Last Answer : Answer: A

Description : In the construction of D.C. motors, parts of both the series and shunt fields are wound on the _____________. A. opposite main pole B. rotor core C. interpole D. same main pole

Last Answer : Answer: D

Description : An operating characteristic appearing on the name plates of shipboard AC motors is _____________. A. the type of winding B. input kilowatts C. temperature rise D. locked rotor torque

Last Answer : Answer: C

Description : Why a dc series motor has a high starting torque?

Last Answer : motor

Description : Which motor has high Starting Torque and Staring current DC motor, Induction motor or Synchronous motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : Which Motor Has High Starting Torque And Staring Current Dc Motor, Induction Motor Or Synchronous Motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : To limit the current flow through a DC voltmeter to as low a value as possible, the moving coil circuit is provided with a/an _____________. A. high series resistance B. high parallel resistance C. series inductor D. external shunt

Last Answer : Answer: A

Description : The d.c. series motor should always be started with load because (A) at no load, it will rotate at dangerously high speed. (B) it will fail to start. (C) it will not develop high starting torque. (D) all are true.

Last Answer : (A) at no load, it will rotate at dangerously high speed.

Description : Basic operating characteristics of the operational amplifier such as gain and stability are the function of its _____________. A. differential input stage B. power output stage C. feedback circuit D. supply voltages

Last Answer : Answer: C

Description : The shunt of a DC ammeter should be connected in __________. A. series with the load and in parallel with the meter movement B. parallel with the load and in series with the meter movement C. ... and in parallel with the meter movement D. series with the load and in series with the meter movement

Last Answer : Answer: A

Description : A DC shunt generator has its field windings connected in _____________. A. series with the series windings B. parallel with the field rheostat C. series with the armature windings D. parallel with the armature windings

Last Answer : Answer: D

Description : The most suitable servomotor for low power applications is (A) a dc series motor. (B) a dc shunt motor. (C) an ac two-phase induction motor. (D) an ac series motor.

Last Answer : (B) a dc shunt motor.

Description : Excessive heat in an operating motor controller can result from _____________. A. a closed starter contact B. loose connections C. missing arc chutes D. low motor starting torque

Last Answer : Answer: B

Description : A dc cumulatively compounded motor delivers rated load torque at rated speed. If series field is short circuited, then the armature current and speed will a) Both increases b) Both decreases c) Increases and decreases d) Decreases and increases

Last Answer : Ans: Both increases

Description : Draw the connection diagram of long shunt differential D.C. compound generator.

Last Answer : Ans:

Description : Cumulative analysis for determining surface is more precise than differential analysis, because of the (A) Assumption that all particles in a single fraction are equal in size (B) Fact that screening is more ... all particles in a single fraction are equal in size, is not needed (D) None of these

Last Answer : (C) Assumption that all particles in a single fraction are equal in size, is not needed

Description : The electrical diagram shown in the illustration represents a ___________. EL-0054 A. series-wound motor B. shunt-wound motor C. compound-wound motor D. flat-compounded motor

Last Answer : Answer: C

Description : Why differential protection for PHT motors?

Last Answer : For more than 2500 kW motors it is required to provide differential protection. It is biased Relay against internal phase fault or earth fault very fast. Insensitive to starting current and stalling current. 

Description : If a unloaded shunt motor's field were weakened by rheostat resistance or by an open circuit, the motor would _________. A. overspeed due to reduced CEMF B. stop because of low flux C. continue to run at base speed D. slow down and overheat

Last Answer : Answer: A

Description : Which type of torque is developed in single phase motors?

Last Answer : Pulsating torque is produced.

Description : A series wound DC motor has its armature and field connected in series with a resistor. When the motor is disconnected from its power supply, this motor will exemplify __________. A. the ... the proper connections for an automatic strip heater C. a reversing controller circuit D. dynamic braking

Last Answer : Answer: D

Description : Give two basic speed control scheme of DC shunt motor?

Last Answer : Answer: 1. By using flux control method: in this method a rheostat is connected across the field wdg to control the field current. So by changing the current the flux produced by the field wdg can ... ) can be varied, and since speed is directly proportional to Eb-IaRa the speed can be controlled.

Description : An increase in the amount of current flow through the armature of a shunt motor is the final result of a/an _____________. A. increase in the load on the motor B. decrease in the load on the motor C. increase in counter EMF D. decrease in armature torque

Last Answer : Answer: A

Description : Due to the operating characteristics of the system, time lag fuses (or dual-element fuses) are necessary for use in _____________. A. main lighting circuits B. motor starting circuit C. emergency lighting circuits D. general alarm circuits

Last Answer : Answer: B

Description : When using a megohmmeter to determine which shunt field coil is grounded in a DC machine, you must ____________. A. insulate the field frame from the ship's hull B. disconnect each shunt ... C. use a motor driven high capacity megohmmeter D. remove all main line lead connections before testing

Last Answer : Answer: B

Description : If a DC motor runs hot, the cause may be _____________. A. high mica condition B. low ambient temperature C. clogged ventilation ducts D. an open in the shunt field

Last Answer : Answer: C

Description : An AC generator operating in parallel loses its excitation without tripping the circuit breaker. This will __________. A. not affect the faulty generator due to the compensation of the other generators B. ... between the armature and the bus D. cause high currents to be induced in the field windings

Last Answer : Answer: D

Description : Give formula for maximum starting torque.

Last Answer : Ts = k ФE2/2R2