Description : The type of control circuit that will not permit automatic restarting after power is restored, following a power failure is called _____________. A. low voltage protection B. low voltage release C. overload lockout D. reduced voltage restart
Last Answer : Answer: A
Description : As shown in the illustration, which of the following conditions will occur as a result of a momentary loss of power? EL-0017 A. The motor will automatically restart when power is restored. B. 'H-4' will open, ... the motor. D. 'A-1' or 'A-2' will open, necessitating a manual restarting of the motor.
Last Answer : Answer: B
Description : Where automatic restart does not present a hazard after a power failure, Coast Guard Regulations (46 CFR) require motor controllers for auxiliaries vital to the propelling equipment to be provided ... overload protection B. low voltage protection C. low voltage release D. reverse current protection
Last Answer : Answer: C
Description : A low-voltage protection circuit is used in electric motor starting equipment to _____________. A. trip circuit contactors when the motor overspeeds due to low voltage B. trip circuit ... voltage without manually resetting D. prevent the motor from restarting automatically on restoration of voltage
Last Answer : Answer: D
Description : An overload in which of the listed motors will result in the illumination of an indicating light at the propulsion control station alarm panel? A. Fuel pump motor B. Steering motor C. Condensate pump motor D. Forced draft blower motor
Description : Coast Guard Regulations (46 CFR), require that an indicating light at the propulsion control station will operate if overloading or overheating occurs in a _______________. A. forced draft blower motor B. steering gear motor C. fuel pump motor D. condensate pump motor
Description : Which of the listed items will stop a motor due to a reduction in voltage and restart it when the voltage is restored to normal? A. Low voltage protection circuit B. Non-renewable link fuse C. Renewable link fuse D. Low voltage release circuit
Description : If overloading a DC machine becomes necessary in an emergency, you should ____________. A. cool the machine with portable blowers and fans B. hold thermal overload relays open with blocks of ... the windings for cooling D. increase the residual magnetism value of windings to reduce eddy currents
Description : If the steering stand selector switch is allowed to remain in the 'Non-Followup' mode after testing of the steering gear, the rudder will _____________. EL-0097 A. not respond to commands from the ... actuator D. stop moving only when the helm is counter-rotated to put the pump at neutral stroke
Description : If a three-phase induction motor malfunctions and drops to a single-phase (one supply line open) ____________. A. the motor will continue to run if it is not heavily loaded B. more torque will be ... be able to be restarted D. the motor will immediately stop and can only be restarted at no load
Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed
Description : Coast Guard Regulations (46 CFR) require that lighting fixture globes must be protected by guards if the fixtures are located in the ____________. A. steering gear room B. galley C. living quarters D. wheelhouse
Description : The purpose of a motor undervoltage protection device is to _____________. A. prevent high armature current when power is restored B. start the motor at a very low voltage C. trip the load off the motor in case of fire D. protect personnel from low voltage shocks
Description : What is special about Steering gear Overload safety?
Last Answer : Short Circuit protection and were appropriate-single phase protection is fitted. In addition instead of over current protection an Overload alarm is fitted set to operate at not less than twice normal running current.
Description : Humming or buzzing of electric contacts is a symptom of ____________. A. low voltage on the operating coil B. power failure to the operating coil C. a control circuit ground D. a control circuit overload
Description : The illustrated motor fails to start and gives a loud hum when the start button is depressed, your first action should be to __________. EL-0007 A. disassemble the motor to fix the centrifical ... D. hold the 'M' contactor closed by hand while wearing electrical safety gloves to get motor started
Description : If the motor fails to start and a voltmeter reading between 1 and 6, as illustrated, indicates line voltage, your next step should be to ________. EL-0007 A. replace fuse '10a' B. replace or repair contact 'Ma' C. reset and determine the cause of the overload D. check line voltage between L1 and L3
Description : Low voltage releases as used in some shipboard motor starter and control equipment will have which of the following characteristics? A. They trip circuit contactors when the motor starts to overspeed. B. ... coil of the starter. D. They allow the motor to restart upon restoration of normal voltage.
Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.
Description : If power were lost to the winch shown in the illustration while in 'second point hoist' the winch would stop. When power is restored the winch would ______________. EL-0102 A. continue to run at ' ... switch' is returned to 'off' closing the 'reset' contacts and then moved to any 'run' position
Description : A three-phase, induction-type motor experiences an open in one phase. Which of the listed automatic protective devices will prevent the machine from being damaged? A. Overspeed trip B. Thermal overload relay C. Three-pole safety switch D. Magnetic blowout coil
Description : Thermal overload relays are used to protect the motor against over current due to (a) short-circuits (b) heavy loads (c) grounds (d) all of the above
Last Answer : (b) heavy loads
Last Answer : Thermal overload relays are used to protect the motor against overcurrent due to heavy loads.
Description : The 'reset' contacts of the master switch shown in the illustration provides the winch controller with ___________. EL-0102 A. low voltage release B. overload protection C. low voltage protection D. high power factor correction
Description : If a synchronous motor begins to vibrate severely and pull out of synchronism, the cause may be ____________. A. an overload B. an open in the field coils C. no exciter voltage D. all of the above
Description : In accordance with Coast Guard Regulations (46 CFR), a steering gear feeder circuit from the emergency switchboard or alternate power supply must have the capacity for continuous operation of the rudder 15° side to side in not more than 60 seconds for a A. 1/4 hour B. 1/2 hour C. 1 hour D. 2 hours
Description : According to Coast Guard Regulations (46 CFR), which of the following systems must be arranged so as to be energized by the final emergency power source? A. at least one light in the ... operated watertight door system C. each charging panel for temporary emergency batteries D. all of the above
Description : As shown in the illustrations, ordered rudder angle is fed back from the ________________. EL-0097 A. power unit to the magnetic amplifier B. steering gear to the control potentiometer C. magnetic amplifier to the steering gear D. rudder yoke to the non-followup controller
Description : The type of feature afforded auxiliaries vital to the operation of propelling equipment, where automatic restart after a voltage failure would not create a hazard, is termed _____________. A. low voltage protection B. high amperage protection C. low voltage release D. high amperage release
Description : What is the difference between an auto reset and manual reset overload relay?
Last Answer : a. Auto reset relay closes its contacts when the bimetallic strip gets cooled. In manual reset relay we have to manually reset the relay because even though bimetallic strip cools its contacts are not ... . Manual over load relay is reseted by pushing the reset button provided on the MCC cell.
Description : Power necessary to operate the horn relay shown in the illustration ____________. EL-0093 A. comes from each station's magneto B. is supplied from a 115 volt source C. is conducted through the relay's contacts D. also lights lamps 'R' and 'T'
Description : The purpose of the reverse power relay, provided on a ship's service alternator panel, is to trip the circuit in the event of ______________. A. main circuit overload B. high power transfer C. generator overspeeding D. alternator motorization
Description : The purpose of a main switchboard circuit breaker's reverse-power trip is to _____________. A. prevent main circuit overload B. protect the circuit breaker blowout coil C. prevent alternator motorization D. prevent low voltage tripout
Description : Component F in the illustrated device is for _________. EL-0033 A. short circut protection B. latching the trip unit closed after resetting the breaker C. overload protection D. providing a flexible connection between the input terminal G and the tripping unit E
Description : 3 The whole email server may be targeted for a complete interruption of services with these failure like A)Storage overload and bandwidth blocking
Last Answer : A)Storage overload and bandwidth blocking
Description : The whole email server may be targeted for a complete interruption of services with these failure like A)Storage overload and bandwidth blocking
Description : How will a molded-case circuit breaker react after it has tripped, as a result of an overloaded circuit? A. The breaker will trip again if immediately reset. B. The breaker handle will lock in ... down. D. The breaker handle cannot be moved to the OFF position until the thermal element cools down.
Description : You have changed a database parameter stored in spfile to an incorrect value. When you try to restart the database, the database only gets as far as startup. How can you correct this error? A. Edit ... the Oracle command - a. Create pfile='pfile' from spfile b. Reset the parameter in file pfile
Last Answer : b. Reset the parameter in file pfile
Description : As a result of a mechanical malfunction in one of the ship's service generators operating in parallel, you must secure that generator. In order to prevent a possible overload to the ... feeder circuit breakers, the malfunctioning prime mover turbine throttle trip, and the generator circuit breaker.
Description : As shown in the illustration, 'S' is the __________. EL-0017 A. safety switch B. overload trip C. start button D. stop button
Description : The arc resulting from the tripping of a circuit breaker is prevented from damaging the contacts by _____________. A. designing the contacts to open slowly B. directing the arc into an ... an inverse timed thermal trip for short circuit currents D. instantaneous magnetic trip for overload currents
Description : The set point current at which a magnetic-type overload relay tends to trip may be increased by turning the dashpot in the 'lower' direction. This action _____________. A. reduces magnetic force on ... the relay D. increases magnetic force on the plunger and requires less current to trip the relay
Description : Fuses placed in series with a thermal trip-type circuit breaker are used for _____________. A. time-delay protection B. short-circuit protection C. short duration surge protection D. sustained overload protection
Description : Protection against sustained overloads occurring in molded-case circuit breakers is provided by a/an __________. A. overvoltage release B. thermal acting trip C. thermal overload relay D. current overload relay
Description : The current at which a magnetic-type overload relay tends to trip may be decreased by raising the plunger further into the magnetic circuit of the relay. This action ___________. A. reduces magnetic ... the relay D. increases magnetic pull on the plunger and requires less current to trip the relay
Description : Overload relays are of...... type. (a) induction (b) solid state (c) thermal (d) electromagnetic (e) all above
Last Answer : (e) all above
Description : What is the normal setting of overload relays?
Last Answer : Ask E/O. Normally 90-100% of rated normal current. Sometimes can be set to 105% of rated current.
Last Answer : Overload relays are of induction, solid state, thermal, electromagnetic type.
Description : Which of the motors for the devices listed below is fitted with an instantaneous overload relay? A. Fan B. Pump C. Winch D. Machine tool
Description : An instantaneous-trip-type fuse will _____________. A. open as soon as the load current exceeds its set point B. allow a preset delay between overcurrent and melting C. open a circuit by using a time delay element with a magnetic trip D. reset itself when the overcurrent is corrected