Routine maintenance of a ship's service alternator should include ______________. A. changing the pedestal bearing insulation yearly B. megger testing of all rectifying diodes C. lubricating excitation slip rings D. periodic cleaning of the air filters or screens

1 Answer

Answer :

Answer: D

Related questions

Description : Routine maintenance of dry-type transformers should include ______________. A. preventing the entrance of water from broken pipe lines steam lines B. keeping protective surfaces and insulating bushings free of ... debris C. periodic testing of insulation resistance with a megger D. all of the above

Last Answer : Answer: D

Description : Two contributors of electronic console failures are heat and vibration. To combat some of their effects, preventive maintenance procedures should include ______________. A. systematic rotation of circuit cards with those ... bolts and changing of the air in the control room D. all of the above

Last Answer : Answer: B

Description : In addition to testing the calibration of a circuit breaker, maintenance should include all of the following EXCEPT ______________. A. changing out of magnetic elements and thermal heaters yearly B. ... for loose or missing parts D. making sure foreign matter does not block tripping element

Last Answer : Answer: A

Description : Routine maintenance of dry-type transformers should include ____________. A. cleaning the windings, if accessible, with a vacuum cleaner or very low pressure air B. measuring and recording the winding ... . making sure that the units are close to bulkheads or corners to protect them from damage

Last Answer : Answer: A

Description : Routine A.C. motor maintenance should include periodic ______________. A. thermometer readings at normal loads to detect abnormal temperature rises B. inspection of the motor's internals for loose rotor bars ... C. bearing replacement each year using sealed units if available D. all of the above

Last Answer : Answer: A

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Description : The reversal of an AC, three-phase, induction motor is accomplished by ______________. A. changing all three motor leads B. reversing the position of the slip rings C. interchanging any two of the three motor leads D. interchanging any two brushes

Last Answer : Answer: C

Description : The purpose of the reverse power relay, provided on a ship's service alternator panel, is to trip the circuit in the event of ______________. A. main circuit overload B. high power transfer C. generator overspeeding D. alternator motorization

Last Answer : Answer: D

Description : On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. To check this insulation with the machine assembled you should use a____________. A. millivolt meter and a jumper B. ohmmeter C. megohm meter D. high potential tester

Last Answer : Answer: A

Description : On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. To check this insulation with the machine assembled you should use a____________. A. ohmmeter with the ... C. megohm meter with the machine running D. voltmeter and ampmeter with the machine running

Last Answer : Answer: B

Description : If the bearings of an electrical generator are failing more frequently than expected and the lubricating oil is sludging then you should ______________. A. check the connections to the output leads B. ... replace the bearing with a sealed roller type D. replace the thrust bearing of the prime mover

Last Answer : Answer: B

Description : The rotor of a synchronous motor operates in synchronism with the rotating field because ______________. A. of the amortisseur windings B. the rotor is magnetically locked into step with the ... field strength varies directly with rotor slip D. the stator flux rotates in the opposite direction

Last Answer : Answer: B

Description : An AC generator operating in parallel loses its excitation without tripping the circuit breaker. This will __________. A. not affect the faulty generator due to the compensation of the other generators B. ... between the armature and the bus D. cause high currents to be induced in the field windings

Last Answer : Answer: D

Description : Chattering of the collector ring brushes on a generator may be remedied by _____________. A. lubricating brush holders B. reinsulating the brushes C. cleaning the collector rings D. increasing length of pigtail

Last Answer : Answer: C

Description : Which of the listed conditions could indicate the need for cleaning electrical insulation? A. Low ambient temperature B. Low operating temperature C. High dielectric strength D. Low megger readings

Last Answer : Answer: D

Description : The need for insulation cleaning may be determined by _____. A. visual inspection for dirt accumulation B. high megger readings C. low operating temperature D. the time period since the last cleaning

Last Answer : Answer: A

Description : Electrical machinery insulation will break down more rapidly due to _________________. A. low loading of motors and generators B. frequent megger testing C. high temperatures and vibration D. high operating frequencies

Last Answer : Answer: C

Description : In actual applications, electrical connections to 'R1-R2' of figure 'A' and to 'R1-R2- R3' of figure 'B' shown in the illustration are made by ______________. EL-0092 A. soldered contacts B. spliced and taped connections C. slip rings and brushes D. solderless crimp-on connectors

Last Answer : Answer: C

Description : An alternator will fail to produce line voltage as a result of _____________. A. a closed circuit breaker B. oxidized slip rings C. improperly staggered brushes D. exciter generator failure

Last Answer : Answer: D

Description : The current from the stator of an alternator is taken out to the external load circuit through (A) slip rings. (B) commutator segments. (C) solid connections. (D) carbon brushes.

Last Answer : (C) solid connections.

Description : As part of a routine maintenance program for deck machinery, you should ___________. A. inspect electrical wiring and pushbutton switches for evidence of corrosion or burned insulation B. disassemble ... covers and ventilate as weather permits D. Check drum switch contact pressure every three months

Last Answer : Answer: A

Description : The only point in the steering stand shown in the illustration which needs periodic lubrication is the ______________. EL-0098 A. repeater assembly ball bearings B. steering wheel bearing C. operation selector switch D. course selector pointer

Last Answer : Answer: B

Description : Before testing insulation with a megohmmeter, the windings of large machines should be grounded for about 15 minutes just prior to the test as the ______________. A. insulation may be damaged ... number of leakage paths D. larger machines may acquire a charge of static electricity during operation

Last Answer : Answer: D

Description : Periodic testing by a shoreside support technician using a special camera which can detect potentially dangerous loose or corroded bus bar and controller connections is termed ______________. A. heat sensitive thermography B. visual pyrotronics C. corrosion electrolysis D. electric vibroanalysis

Last Answer : Answer: A

Description : Common basic applications for the operational amplifier include ____________. A. counting, pulsing and clocking amplifiers B. summing, scaling and difference amplifiers C. step-up, step-down and rectifying amplifiers D. all of the above

Last Answer : Answer: B

Description : Routine maintenance of lead acid batteries should include _____________. A. keeping the terminals clean B. coating cable connections with petroleum jelly C. maintaining a trickle charge D. all of the above

Last Answer : Answer: D

Description : An electrical device which employs a stationary armature and a rotating electromagnetic field is used aboard ship as a ____________. A. magnetic amplifier B. ship's service alternator C. three-wire DC generator D. saturable core reactor

Last Answer : Answer: B

Description : The reading at 'K' on the megger scale shown in the illustration, is ______________. EL-0044 A. 400 ohms B. 4,000 ohms C. 40,000 ohms D. 400,000 ohms

Last Answer : Answer: D

Description : Complete controller maintenance includes _____________. A. periodic testing of protective devices B. checking for loose or worn contacts and weak springs C. maintaining a sufficient supply of spare parts D. all of the above

Last Answer : Answer: D

Description : Which of the conditions listed will indicate the need to clean the insulation on the windings of an electric motor? A. Higher than normal operating temperature. B. Excessive vibration at normal speed. C. Sparking at the brushes. D. High megger readings.

Last Answer : Answer: A

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : Complete maintenance of electrical motors should include periodic checks for machine _____________. A. vibration B. watertight integrity C. speed droop D. reactive power

Last Answer : Answer: A

Description : On some diesel-electric ships, the DC propulsion motor will only attain half speed when the generator fields are fully excited. Speeds above this are obtained by _____________. A. rotating brush ... B. raising the generator engine speed C. lowering the generator engine speed D. decreasing excitation

Last Answer : Answer: B

Description : As shown in the illustration, what maintenance would be required of the circuit components? EL-0058 A. Change out both 'C' units monthly. B. Clean the glass surrounding 'E1' & 'E2' as needed. C. File ... upper end of 'G' every six months. D. Take megger readings on 'E1' & 'E2' windings quarterly.

Last Answer : Answer: B

Description : The most common source of excitation for synchronous motors is a/an ______________. A. stepup transformer B. half-wave rectifier C. DC supply D. AC supply

Last Answer : Answer: C

Description : If the excitation of an alternator operating in parallel is decreased below normal, its _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. ampere load will be greatly increased D. kilowatt load will be greatly decreased

Last Answer : Answer: B

Description : If field excitation is suddenly lost to an alternator operating in parallel, that alternator will _____________. A. supply excessive current to the bus B. operate at the same load, but with reduced voltage C. lose its load and tend to overspeed D. become overloaded and slow down

Last Answer : Answer: C

Description : A change in field excitation of an alternator operating in parallel will cause a change in its _____________. A. alternator frequency B. kilowatt load C. voltage output D. all of the above

Last Answer : Answer: C

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation of the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. type of alternator

Last Answer : Answer: B

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation to the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. number of field poles per alternator

Last Answer : Answer: B

Description : RC time constant characteristics, as shown in the illustration, are important in _____________. EL-0086 A. bridge rectifiers for alternator excitation B. timing and pulse shaping circuits C. transistor power amplifier biasing D. motor controller overload protection

Last Answer : Answer: B

Description : How does increase in excitation of the Alternator connected to infinite bus-bars affect this operation?

Last Answer : Increase in excitation level of the synchronous generator will effectively increase the reactive power supplied by the generator keeping steam input constant.

Description : What happens if speed of prime mover is changed keeping excitation of alternator constant?

Last Answer : If speed of prime mover is changed, the speed of alternator also changes hence frequency also changes. The frequency increase with increase in steam input and hence speed and vise versa.

Description : What happens if excitation of alternator is changed keeping speed of prime mover constant?

Last Answer : The emf induced will be changed and hence terminal voltage will also change. The terminal voltage will increase with increase in excitation and vise versa.

Description : When Alternator excitation increases and machine is operating at lagging power factor then a) I increase b) I decreases c) No effect on current d) None

Last Answer : Ans: I increase