All of the following items can be used in the maintenance of a D.C. propulsion motor's commutator EXCEPT _______________. A. a canvas wiper  B. safety solvent C. abrasive dressing stones D. sandpaper

1 Answer

Answer :

Answer: B

Related questions

Description : For routine cleaning of a commutator, you should apply _____________. A. course sandpaper in a slow back and forth motion across the commutator slots B. an emery cloth parallel to the axis of the machine C. a canvas wiper to the machine while running D. cotton swabs between the commutator bars

Last Answer : Answer: C

Description : Which of the following materials is recommended for finishing the slip rings after grinding or turning? A. grade 00 sandpaper B. canvas wiper C. crocus cloth D. smooth file

Last Answer : Answer: C

Description : In addition to undercutting the mica, proper maintenance of a D.C. motor's commutator includes _______________. A. side-cutting the copper segments and insulating the slots B. coating the copper surface with light machine ... in an oven at a maximum of 95°C for not over 8 hours D. all of the above

Last Answer : Answer: A

Description : To effectively clean a commutator in good physical condition, you should use ____________. A. trichloride ethylene B. kerosene C. a canvas wiper D. a commutator stone

Last Answer : Answer: C

Description : In general, D.C. propulsion motor brush sparking can be caused by _______________. A. incorrect brush grade, pressure or position B. a concentric commutator C. a dark chocolate colored commutator D. all of the above

Last Answer : Answer: A

Description : Uneven wear of the commutator surface on a direct current propulsion motor can be caused by _____________. A. rapid change in load B. excessive operation at light load C. incorrect brush staggering D. unequal pole spacing

Last Answer : Answer: C

Description : Temporary repairs to an open DC propulsion armature coil can be made by _____________. A. connecting the coil ends directly to a pair of negative brushes B. disconnecting coil ends, insulating ... C. grounding the coil ends and short circuiting the commutator bar D. removing the sparking brushes

Last Answer : Answer: B

Description : Which of the listed procedures should be carried out to prevent moisture damage to electrical apparatus during extended periods of idleness? A. Fill the motor housing with CO2 to inert the space. B. Strap ... C. Place heat lamps in the motor housings. D. Cover the equipment with a canvas tarpaulin.

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR), require that an indicating light at the propulsion control station will operate if overloading or overheating occurs in a _______________. A. forced draft blower motor B. steering gear motor C. fuel pump motor D. condensate pump motor

Last Answer : Answer: B

Description : In D.C. motor construction, the armature coils' ends are _______________. A. soldered to the commutator bar risers B. imbedded into core slots C. crimped together with brush pigtails D. spliced with the field windings

Last Answer : Answer: A

Description : An important factor in reducing D.C. motor commutator wear is _______________. A. keeping the ambient humidity as low as possible B. ensuring a very low brush current density C. establishing the copper oxide surface film D. all of the above

Last Answer : Answer: C

Description : Basic electrical motor action depends on _______________. A. a conductor rotated within a magnetic field B. a current carrying conductor placed in a magnetic field C. the relative force of the commutator and commutating poles D. the relative force of the armature and interpoles

Last Answer : Answer: B

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Description : An overload in which of the listed motors will result in the illumination of an indicating light at the propulsion control station alarm panel? A. Fuel pump motor B. Steering motor C. Condensate pump motor D. Forced draft blower motor

Last Answer : Answer: B

Description : The most practical method used for resurfacing a ship's service motor commutator is to _____________. A. turn it down in the ship's lathe B. use a grinding rig C. use a hand stone D. burnish it with commutator stones

Last Answer : Answer: B

Description : Which of the following is a characteristic of fractional horsepower repulsion start motors? A. They start with a rotating stator field. B. The short circuiting ring is removed from the commutator while ... brushes are removed from the commutator while starting. D. They have a low starting torque.

Last Answer : Answer: B

Description : Grease coatings on electrical contact surfaces increase contact resistance and should be removed with a/an _______________. A. small wire brush B. compressed air jet C. clean dry cloth D. 10% solution carbon solvent and water

Last Answer : Answer: C

Description : During maintenance of circuit breakers, _______________. A. always smooth roughened contact surfaces with a file B. never pass more than rated breaker current through the overload heater element C. ... wear and misalignment of main contacts D. assume heater elements installed are of correct size

Last Answer : Answer: C

Description : Nickel-cadmium batteries are superior to lead-acid batteries at high discharge rates because they _______________. A. deliver a large amount of power and can be recharged in a shorter time B. need ... less mounting space C. have higher output voltages and require no maintenance D. all of the above

Last Answer : Answer: A

Description : An advantage of DC motors over AC motors is that they _____________. A. are less expensive B. require less maintenance C. offer infinite speed variation D. all of the above

Last Answer : Answer: C

Description : When disassembling electric motors for maintenance or overhaul, ________________. A. punch mark frame and end bells for proper assembly B. wrap bearings in lint free cloths if they are to be reused C. tag and store small parts in a box D. all of the above

Last Answer : Answer: D

Description : Routine A.C. motor maintenance should include periodic ______________. A. thermometer readings at normal loads to detect abnormal temperature rises B. inspection of the motor's internals for loose rotor bars ... C. bearing replacement each year using sealed units if available D. all of the above

Last Answer : Answer: A

Description : Complete maintenance of electrical motors should include periodic checks for machine _____________. A. vibration B. watertight integrity C. speed droop D. reactive power

Last Answer : Answer: A

Description : An advantage of DC motors over AC motors is that they _____________. A. are less expensive B. require less maintenance C. can be started across the line D. offer a more effective means of controlling speed

Last Answer : Answer: D

Description : Routine maintenance of dry-type transformers should include ____________. A. cleaning the windings, if accessible, with a vacuum cleaner or very low pressure air B. measuring and recording the winding ... . making sure that the units are close to bulkheads or corners to protect them from damage

Last Answer : Answer: A

Description : Which of the listed faults cannot be eliminated, EXCEPT by turning or grinding a commutator with a rigidly supported tool? A. Sparking brushes B. Eccentricity C. High mica D. Blackened commutator

Last Answer : Answer: B

Description : Seating the brushes on a D.C. motor is first accomplished using ________________. A. a file for cutting the approximate curvature followed by sandpaper for the final fit B. sandpaper with the motor not ... for the finishing cut D. course lapping compound, followed by a medium and then a fine grade

Last Answer : Answer: B

Description : Which of the following statements represents the FIRST step in seating new brushes on slip rings? A. Wrap sandpaper around the slip rings and slide it back and forth between the brushes and the slip rings. B. ... to 4 hours. D. Apply seating compound under the brushes and run at no load for 2 hours.

Last Answer : Answer: A

Description : Which of the following methods should be used to dress the face of silver-plated contacts? A. Filing B. Burnishing C. Sanding with 0000 sandpaper D. All of the above are correct.

Last Answer : Answer: C

Description : Which of the following statements is true concerning the cleaning of electrical contacts? A. Compressed air should be used to blow out metallic dust. B. Magnetic brushes should be used to remove ... contact resistance. D. Delicate parts should be cleaned with a brush and an approved safety solvent.

Last Answer : Answer: D

Description : The preparation of surface of stone to obtain plain edges or to obtain stones of required size and shape is known as (A) Quarrying of stones (B) Blasting of stones (C) Seasoning of stones (D) Dressing of stones

Last Answer : Answer: Option D

Description : Cross cut saw is used for (A) Cutting soft stones (B) Cutting hard stones (C) Cutting large blocks of stones (D) Dressing stones

Last Answer : Answer: Option B

Description : Spalling hammer is used for (A) Driving wooden headed chisels (B) Rough dressing of stones (C) Carving of stones (D) Breaking small projection of stones

Last Answer : Answer: Option B

Description : Jumper is a tool used for (A) Testing of stones (B) Quarrying of stones (C) Dressing of stones (D) None of the above

Last Answer : Answer: Option B

Description : The thre The three groups o e groups of indust f industrial pr rial products a oducts and servi nd services inc ces include all of t lude all of the foll he following exc owing except _____. a. materials and parts b. capital items capital items c. maintenance and operations d. supplies and services

Last Answer : c. maintenance and operations

Description : In order to decrease the resistance of the 50K pot located at '21Q/R' shown in the illustration, the wiper of the actual component must be moved ____________. EL-0099 A. to the left B. to the right C. clockwise D. counterclockwise

Last Answer : Answer: D

Description : The removal of paint from electrical equipment, such as generators, should be cautiously undertaken because ____________. A. the mechanical shock of paint removal lessens the dielectric strength ... phase windings frequently become isolated from each other due to dust interference at the terminals

Last Answer : Answer: B

Description : _______________ doctrine places the responsibility of product safety on corporations A. Buyer beware B. Seller beware C. Seller take care D. Buyer and seller take care

Last Answer : C. Seller take care

Description : In addition to testing the calibration of a circuit breaker, maintenance should include all of the following EXCEPT ______________. A. changing out of magnetic elements and thermal heaters yearly B. ... for loose or missing parts D. making sure foreign matter does not block tripping element

Last Answer : Answer: A

Description : Sparking at the brushes of a DC propulsion motor can be the result of ____________. A. improper brush pressure B. improper brush seating C. reversed interpole polarity D. all of the above

Last Answer : Answer: D

Description : A four pole turbogenerator is used in conjunction with a 160 pole propulsion motor. If the generator is turning at 3,200 RPM, what is the current speed of the propeller? A. 40 RPM B. 60 RPM C. 80 RPM D. 100 RPM

Last Answer : Answer: C

Description : The prime mover of an AC two pole main propulsion generator drives the generator at 3600 RPM. If the main propulsion motor has 80 poles, what will be the propeller speed? A. 45 RPM B. 80 RPM C. 90 RPM D. 180 RPM

Last Answer : Answer: C

Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil

Last Answer : Answer: B

Description : D.C. propulsion motor brush pressure depends on the brush grade used and in practice is set with a ______________. A. multimeter B. manometer C. spring scale D. compound gauge

Last Answer : Answer: C

Description : Propulsion DC motor brush pressures can be calculated by _____________. A. dividing the brush contact area by the spring pressure B. subtracting the brush contact area from the spring pressure C. ... force by the brush contact area D. subtracting the spring pressure from the brush contact area

Last Answer : Answer: C

Description : The direction of rotation of a DC propulsion motor can be changed by reversing the _____________. A. brush holder position B. polarity of the field poles C. brush staggered order D. motor interpole connections

Last Answer : Answer: B

Description : The direction of propeller shaft rotation in a turbo-electric synchronous propulsion drive motor is changed by reversing the _____________. A. polarity of the propulsion motor B. polarity of the propulsion generator C. phase sequence of power to the motor D. phase sequence of power to the generator

Last Answer : Answer: C

Description : If you reverse both the field and the armature connections to a DC propulsion motor, _____________. A. the direction of motor rotation will change B. the brushes will become overheated C. a magnetic lock will occur in the motor D. the direction of motor rotation will remain the same

Last Answer : Answer: D