Before using an all-purpose electric measuring instrument (multimeter) utilizing internal batteries to supply power for resistance measurements, you should FIRST ____________. A. remove one of the batteries B. remove all the batteries C. calibrate using a known external resistance D. select the proper resistance range

1 Answer

Answer :

Answer: D

Related questions

Description : When using a multimeter for resistance measurements, it should be calibrated by clipping the loose ends of the leads together and _____________. A. setting the instrument pointer at 'zero' ohms B. ... the plus and minus terminals D. using a special purpose resistance measuring instrument (a bridge)

Last Answer : Answer: A

Description : You are calibrating a multimeter using internal batteries to supply power for resistance measurements. However, you are unable to adjust the pointer to 'zero' using the adjustment knob. Therefore, you should ... change scales to the R X 100 scale and adjust using the 'zero ohms' adjusting knob

Last Answer : Answer: A

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointers to mid-scale B. change the meter's batteries C. center the meter's pointer at infinity D. short the test leads and calibrate the meter

Last Answer : Answer: D

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointer to mid-scale B. short the test leads and calibrate the meter reading to 'zero' C. change the meter's batteries D. center the meter's pointer at infinity

Last Answer : Answer: B

Description : The Wheatstone bridge is a precision measuring instrument utilizing the principle of changes in _____________. A. inductance B. capacitance C. resistance D. amperage

Last Answer : Answer: C

Description : Vibration measuring instruments are classified on the basis of ____________. (A) contact between the vibrating system and measuring instrument (B) the requirement of power source (C) method of measurements (D) all of the above

Last Answer : (D) all of the above

Description : When used for taking resistance measurements, a volt-ohm-milliammeter is normally powered by _____________. A. a hand cranked generator B. internal storage batteries C. the current in the circuit being tested D. a step down transformer

Last Answer : Answer: B

Description : If the approximate voltage to be measured in a circuit is not known, you should _____________. A. use the lowest voltage range on the voltmeter B. connect the meter in series with the circuit C. only have to calibrate the meter before using it D. use the highest voltage range on the voltmeter

Last Answer : Answer: D

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D

Description : Which of the following statements regarding the use of a current measuring instrument is correct? A. It must be connected in series with the circuit. B. You should always start with the lowest range ... of polarity. D. An external shunt is generally utilized where current is less than 10 amperes.

Last Answer : Answer: A

Description : Which of the listed statements is correct when using an analog multimeter as an ohmmeter? A. The pointer should be adjusted to zero each time a new resistance range is selected. B. The ... C. Ohmmeters are not sufficiently sized to measure conductor insulation resistance. D. All of the above.

Last Answer : Answer: D

Description : When measuring AC current flow, you must always connect the meter _____________. A. in series with the power source and load B. in parallel with the power source and load C. insuring correct polarity D. using the lowest range possible to prevent instrument damage

Last Answer : Answer: A

Description : What is the resistance value indicated on the multimeter scale illustrated, if the range switch is set at R X 100, and the needle is at the position indicated by the letter 'R'? EL-0047 A. 6.0 ohms B. 162.5 ohms C. 600 ohms D. 16,250 ohms

Last Answer : Answer: C

Description : What is the resistance value indicated by the multimeter scale illustrated, if the range switch is set at R X 100, and the needle is at the position indicated by the letter 'Y'? EL-0047 A. 220 ohms B. 240 ohms C. 2,400 ohms D. 24,000 ohms

Last Answer : Answer: C

Description : What is the resistance value indicated by the multimeter scale illustrated, if the range switch is set at R X 1, and the needle is at the position indicated by the letter 'A'? EL-0047 A. 10 ohms B. 100 ohms C. 200 ohms D. 1,000 ohms

Last Answer : Answer: C

Description : What is the resistance value indicated by the multimeter scale illustrated, if the range switch is set at R X 1, and the needle is at the position indicated by the letter 'F'? EL-0047 A. 0.6 ohms B. 6 ohms C. 9.6 ohms D. .38 ohms

Last Answer : Answer: A

Description : What is the resistance value indicated by the multimeter scale illustrated, if the range switch is set at R X 1, and the needle is at the position indicated by the letter 'D'? EL-0047 A. 7.8 ohms B. 8 ohms C. 3.6 ohms D. .36 ohms

Last Answer : Answer: C

Description : What is the resistance value indicated by the multimeter scale illustrated, if the range switch is set at R X 1, and the needle is at the position indicated by the letter 'R'? EL-0047 A. 6 ohms B. 6.8 ohms C. 1.7 ohms D. 167 ohms

Last Answer : Answer: A

Description : What is the resistance value indicated by the multimeter scale illustrated, if the range switch is set at R X 1, and the needle is at the position indicated by the letter 'X'? EL-0047 A. 8 ohms B. 6.2 ohms C. 1.57 ohms D. 150 ohms

Last Answer : Answer: A

Description : What is the resistance value indicated by the multimeter scale illustrated, if the range switch is set at R X 1, and the needle is at the position indicated by the letter 'C'? EL-0047 A. 1.3 ohms B. 4.8 ohms C. 13 ohms D. 121 ohms

Last Answer : Answer: C

Description : What is the resistance value indicated by the multimeter scale illustrated, if the range switch is set at R X 1, and the needle is at the position indicated by the letter 'B'? EL-0047 A. 1.45 ohms B. 7.2 ohms C. 37 ohms D. 70 ohms

Last Answer : Answer: D

Description : What is the resistance value indicated by the multimeter scale illustrated, if the range switch is set at R X 1 and the needle is at the position indicated by the letter 'Y'? EL-0047 A. 2.2 ohms B. 24 ohms C. 240 ohms D. 2,400 ohms

Last Answer : Answer: B

Description : To properly use a hook-on-type volt/ammeter to check current flow, you must FIRST _____________. A. de-energize the circuit to allow connection of the instrument in series B. hook the jaws ... test leads to the appropriate terminals D. short the test leads and calibrate the instrument to zero

Last Answer : Answer: B

Description : Most appropriate instrument for measurement of internal and external diameter of a tube is A. vernier callipers B. micrometer screw gauge C. meter rule D. measuring tape

Last Answer : vernier callipers

Description : When troubleshooting electronic equipment, the FIRST step to be taken before testing the circuit voltage is to _________. A. set the meter to the lowest range B. check the voltage supply from the power source C. remove the suspected component D. check the current flow through the circuit

Last Answer : Answer: B

Description : How is a multimeter changed from a voltage measuring device to a resistance measuring device?

Last Answer : By changing the position of the function switch

Description : Before working on an electric cargo winch master switch or controller, you should _____________. A. spray the gasket surface with a solvent B. drain condensate from the box C. open the circuit breaker in the power supply and tag D. heat the switch box to remove any moisture

Last Answer : Answer: C

Description : A precision Approach Procedure is defined as: a. An approach using bearing, elevation and distance information b. An approach with a crew of at least 2 pilots trained for such operations c. An ... by an ILS or a PAR d. An approach using bearing, elevation, and, optionally, distance information

Last Answer : c. An instrument approach procedure utilizing azimuth and glide path information provided by an ILS or a PAR

Description : A precision Approach Procedure is defined as: a. An approach using bearing, elevation and distance information b. An approach with a crew of at least 2 pilots trained for such ... An instrument approach procedure utilizing azimuth and glide path information provided by an ILS or a PAR

Last Answer : c. An instrument approach procedure utilizing azimuth and glide path information provided by an ILS or a PAR

Description : Two batteries A and B each of e.m.f. 2 V are connected in series to an external resistance R = 1 ohm . If the internal resistance of battery A is 1.9

Last Answer : Two batteries A and B each of e.m.f. 2 V are connected in series to an external resistance R = 1 ohm . If the ... V B. `3.8` V C. zero D. `4.8` V

Description : How will you calibrate an absolute pressure transmitter using vacuum manometer. Range 0-400mm abs ?

Last Answer : The procedure for calibration is as follows : Connect air supply to the transmitter. Connect a test gauge of 0-1.4 Kg/cm2 to the output. Connect Vacuum pump with tee off to the manometer. Apply 760 ... nearest ) and adjust zero. Apply 360 mm Vacuum adjust span. ( 760 - 360 = 400 mm abs. )

Description : When reading AC current with the multimeter shown in the illustration and you are unsure of the range, the range switch should be set to ___________. EL-0047 A. 10 MA/ 10 AMP with leads in the (-10 A ... leads in the (-COMMON) and (+10 A) jacks D. unable to measure AC current with this multimeter

Last Answer : Answer: D

Description : When using a megohmmeter to determine which shunt field coil is grounded in a DC machine, you must ____________. A. insulate the field frame from the ship's hull B. disconnect each shunt ... C. use a motor driven high capacity megohmmeter D. remove all main line lead connections before testing

Last Answer : Answer: B

Description : need of calibration and explain the procedure to calibrate the instrument.

Last Answer : Need of calibration: Every measuring device degrades over time due to normal wear and tear. These changes can be caused by various reasons such as electric or mechanical shock or a hazardous manufacturing ... different magnitude are used to calculate the resistance based on ohm's law.

Description : Prior to taking a resistance reading with a volt-ohm-milliammeter, the 'zero' setting must be adjusted. After clipping the two leads together, you find the adjustment knob will not return the pointer ... range setting B. weak batteries C. a faulty zero ohms knob D. a faulty meter movement

Last Answer : Answer: B

Description : Before using a volt-ohmmeter to measure resistance readings, you should _____________. A. replace all batteries B. test the insulation resistance of the leads C. make sure the test leads do not touch D. hold the leads together and 'zero' the meter

Last Answer : Answer: D

Description : If your multimeter gives a reading in ohms when testing each end of each conductor of a three-conductor cable, this indicates ______________. A. continuity of the conductor B. an infinite resistance C. the presence of a partial ground D. that the conductor is not short circuited

Last Answer : Answer: A

Description : A multimeter can be used to measure _____________. A. resistance B. voltage C. current D. all of the above

Last Answer : Answer: D

Description : A multimeter may be damaged by taking a _____________. A. voltage reading while in the ammeter mode B. current reading while in the voltmeter mode C. resistance reading while in the ammeter mode D. resistance reading while in the voltmeter mode

Last Answer : Answer: A

Description : When you are measuring a component using a bridge, what is the most common cause of inaccurate measurements?

Last Answer : The capacitive and inductive characteristics of the test leads.

Description : Ondometer is a - (1) Measuring instrument for distance covered by motor wheels (2) Measuring instrument for frequency of electromagnetic waves (3) Device for measuring sound intensity (4) Measuring instrument for electric power

Last Answer : (2) Measuring instrument for frequency of electromagnetic waves

Description : In a standard multimeter for measuring AC voltage, parameter of _____ voltage is measured

Last Answer : In a standard multimeter for measuring AC voltage, parameter of RMS voltage is measured

Description : Power for the electronic digital multimeter is normally supplied by what internal power source?

Last Answer : Rechargeable batteries.

Description : Considering the function of the circuit shown in the illustration, what is the purpose of supplying the thrust lever potentiometers with both (+) and (-) 15 volts? EL-0095 A. To select which ... alternate voltage supply if the other fails. D. So as to automatically select the position of Relay #

Last Answer : Answer: B

Description : In precision theodolite traverse if included angles are read twice and the mean reading accepted using both verniers having a least count of 30". Assuming the instrument to be in perfect adjustment, linear measurements correct to 6 mm per ... legs) (A) 50" n (B) 30" n (C) 60" n (D) None of these

Last Answer : (A) 50" n

Description : Before servicing the device indicated as 'A' in panels #1 and #3 of the illustration, the device labeled 'CT' must __________. EL-0003 A. have the disconnected leads taped to prevent ... D. have one lead grounded to discharge static electricity for the prevention of damage to electronic components

Last Answer : Answer: C