In the illustrated test, if the lamp fails to light on any of the three windings then _________. EL-0027 A. all three windings are grounded and the motor should be sent out for repair B. the brushes should be set back on the commutator and the test redone C. the ground is not in the windings and the connections to the motor controller and the controller should be checked D. the test should be redone at a higher voltage

1 Answer

Answer :

Answer: C

Related questions

Description : When using the test set-up shown in the illustration, the lighted lamp indicates the winding is ____________. EL-0027 A. grounded B. good C. open D. shorted

Last Answer : Answer: A

Description : In the illustrated motor controller, the motor fails to start. A voltmeter reading between 1 and 6 reads line voltage, while the voltmeter reading between 2 and 6 reads 0 VAC. The problem is __________. EL- ... in the 'M' coil, 'Ma' contact/start switch or overload contacts D. fuse '10a' is blown

Last Answer : Answer: B

Description : The illustrated motor fails to start and gives a loud hum when the start button is depressed, your first action should be to __________. EL-0007 A. disassemble the motor to fix the centrifical ... D. hold the 'M' contactor closed by hand while wearing electrical safety gloves to get motor started

Last Answer : Answer: B

Description : If the motor fails to start and a voltmeter reading between 1 and 6, as illustrated, indicates line voltage, your next step should be to ________. EL-0007 A. replace fuse '10a' B. replace or repair contact 'Ma' C. reset and determine the cause of the overload D. check line voltage between L1 and L3

Last Answer : Answer: C

Description : Voltage generated by most AC generators is fed from the machine to the bus by means of ____________. A. brushes on a commutator B. brushes on slip rings C. slip rings on a commutator D. direct connections from the stator

Last Answer : Answer: D

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : In the illustrated ground detection system with a ground on phase A, if the switch is opened __________. EL-0009 A. lamp A will dim or go out depending on the severity of the ground B. all three ... lamp A will be brighter D. lamp A will start flickering if the ground is in an AC induction motor

Last Answer : Answer: B

Description : The circuit illustrated represents a 2 wire DC ground detecting system. If the positive bus is grounded and the test button is pushed, which of the lamps will be brightest? EL-0008 A. X B. Y C. both will be equal brightness. D. both will go out.

Last Answer : Answer: C

Description : An open in the armature of a DC motor is suspected, but is not found by visual inspection of the commutator. The next step in troubleshooting this problem is to ________________. A. conduct a ... windings C. conduct an insulation resistance test of the armature D. test the commutator for a ground

Last Answer : Answer: A

Description : Which of the listed conditions might contribute to very rapid wearing of a DC machine's commutator bars? A. A grounded commutator bar B. Using improper carbon brushes C. Aligning the front and rear mica V-rings improperly D. An open circuit in the armature

Last Answer : Answer: B

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : If the supply voltage is 220 volts 60 Hz, what is the operating voltage of the motor controller circuitry illustrated? EL-0011 A. 110 volts DC B. 110 volts AC C. 220 volts DC D. 220 volts AC

Last Answer : Answer: D

Description : Brushes in a generator must be positioned in the neutral plane to avoid sparking between the brushes and the _____________. A. yoke B. armature windings C. field pole windings D. commutator

Last Answer : Answer: D

Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above

Last Answer : Answer: D

Description : Which of the following components are used to convert alternating current produced in the generator windings to direct current? A. Armature and equalizer B. Commutator and brushes C. Rotor and interpoles D. Field and exciter

Last Answer : Answer: B

Description : In an AC generator, direct current from a separate source is passed through the windings of the rotor _____________. A. by means of slip rings and brushes B. by means of a commutator C. by means of rotating bar magnet D. to minimize the danger of arc over

Last Answer : Answer: A

Description : The current from the stator of an alternator is taken out to the external load circuit through (A) slip rings. (B) commutator segments. (C) solid connections. (D) carbon brushes.

Last Answer : (C) solid connections.

Description : If reading the AC voltage from the line lead of a 440 VAC controller the range switch illustrated should be set to ___________. EL-0047 A. 1,000 V B. 250 V C. R X 10,000 D. Unable to safely read with this meter.

Last Answer : Answer: A

Description : One method of testing for a reversed shunt field coil in a DC generator or motor is by connecting the field to a direct current source, at reduced field rated voltage, and test for ... placed near each field C. test lamp across adjacent fields D. copper jumper across the interpole connections

Last Answer : Answer: B

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Description : Which of the conditions listed will indicate the need to clean the insulation on the windings of an electric motor? A. Higher than normal operating temperature. B. Excessive vibration at normal speed. C. Sparking at the brushes. D. High megger readings.

Last Answer : Answer: A

Description : Which of the listed conditions could cause a DC motor to have excessively hot windings and sparking at the brushes? A. Reversed interpole polarity B. High bar-to-bar voltage C. Loose brushes D. Excessive humidity

Last Answer : Answer: A

Description : A flickering ground detection lamp on a DC system would indicate a _____________. A. multiple-ground condition in the distribution system B. ground in an armature coil of an operating machine C. ground in a motor accompanied with a short D. short between two adjacent bars of the generator commutator

Last Answer : Answer: B

Description : If the illustrated motor fails to start and gives a loud hum when the start button is pushed, the problem is ________. EL-0007 A. one of the phases to the motor is not energized because of ... electrical distribution system D. 'OL1' is open because of 'T1' overload causing the motor to single phase

Last Answer : Answer: A

Description : In testing a three-phase delta winding for an open circuit using a megohmmeter, you must ______________. A. test each phase with all connections intact B. measure the voltage across the open ... groups to avoid short circuiting D. open the delta-connections to avoid shunting the phase being tested

Last Answer : Answer: D

Description : In preparing to take insulation resistance readings on a main generator, the windings should be grounded for about 15 minutes prior to the test to _____________. A. allow accurate zeroing of the meter ... the windings D. help the windings to cool to the same temperature as the ground test connection

Last Answer : Answer: C

Description : If reading AC current with the illustrated device and unsure of the range as a precaution , the first step should be to _________. EL-0047 A. secure power and test for voltage B. disconnect the ... resistance and use Ohm's law to calculate current D. unable to safely measure current with the device

Last Answer : Answer: A

Description : Which of the diagrams shown in the illustration depicts the proper method of aligning brushes on a commutator? EL-0057 A. A B. B C. C D. D

Last Answer : Answer: B

Description : The diagram shown in the illustration represents a _________. EL-0058 A. dual speed, 2-winding motor controller B. navigation running light circuit C. single phase, 2-motor selectable starter D. common fluorescent lighting circuit

Last Answer : Answer: B

Description : While starting a main propulsion synchronous motor, the ammeter pegs out at maximum and then returns to the proper value after synchronization. This indicates the _____________. A. motor has started ... field windings are grounded C. slip rings are dirty D. power transmission cables are grounded

Last Answer : Answer: A

Description : In the illustrated three phase alternator, line voltage is _________. EL-0074 A. 1.73 times the phase voltage B. equal to the phase voltage C. phase voltage divided by 1.73 D. unable to answer this question without knowing the line current

Last Answer : Answer: A

Description : In actual applications, electrical connections to 'R1-R2' of figure 'A' and to 'R1-R2- R3' of figure 'B' shown in the illustration are made by ______________. EL-0092 A. soldered contacts B. spliced and taped connections C. slip rings and brushes D. solderless crimp-on connectors

Last Answer : Answer: C

Description : Sparking at the brushes of a running motor could be an indication of _____________. A. normal operation B. a dirty commutator C. increased brush capacity D. water vapor absorption

Last Answer : Answer: B

Description : The function of the commutator in a DC motor is to ________. A. reverse the flow of current through the armature B. reverse the flow of current in the field poles C. reduce the reluctance of the magnetic path through the motor D. shift the neutral running plane of the brushes to prevent sparking

Last Answer : Answer: A

Description : The vertical dotted line connecting the small circular symbols at coordinates '05L', '09L', '13L', '21L', '25L', etc., shown in the illustration, indicate that all _______________. EL-0100 A. contacts are ... board 'TB2' C. wires are grounded at both ends of the line D. wires have a common shield

Last Answer : Answer: B

Description : The purpose of the commutator and brushes on a DC generator is to _____________. A. transfer generated direct current voltage from the armature to the line B. convert the alternating voltage ... contact method to excite the field D. reduce sparking between the armature and the carbon brushes

Last Answer : Answer: B

Description : Which of the following actions must be carried out before a voltage tester can be used to test the three line fuses to a three-phase motor? A. The fuses must be removed from the circuit. B. The ... disconnected and tagged. D. Nothing need be done as long as the motor is running under a light load.

Last Answer : Answer: B

Description : In D.C. motor construction, the armature coils' ends are _______________. A. soldered to the commutator bar risers B. imbedded into core slots C. crimped together with brush pigtails D. spliced with the field windings

Last Answer : Answer: A

Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil

Last Answer : Answer: B

Description : A disadvantage of using the configuration in the illustrated circuit is _________. EL-0045 A. no current gain B. high input resistance C. high voltage gain D. becomes unstable with an increase of ambient temperature

Last Answer : Answer: A

Description : In the illustrated circuit, if the input to leads 'B' and 'Y' was 24 VDC the output between 'A' and 'X' will be _________. EL-0069 A. 24 VDC B. 22.8 VDC, 24 VDC minus the 1.2 VDC voltage drop across two diodes C. undeterminable without knowing the turns ratio of the transformer D. 0 VDC

Last Answer : Answer: D

Description : If a D.C. motor hums, but does not run when energized, which of the listed conditions could exist? A. Incorrect lead connections B. Incorrect brush setting C. A dirty commutator D. All of the above are correct.

Last Answer : Answer: D

Description : Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed? A. The motor would not start. ... direction of rotation of the armature would be unchanged. D. The field pole windings would become overheated.

Last Answer : Answer: C

Description : Which of the following statements describes what will happen when both the polarity of the field poles, and the direction of current to the brushes of a DC motor are reversed? A. The motor will ... of rotation of the armature will remain the same. D. The field pole windings will become overheated.

Last Answer : Answer: C