Which of the following statements is true about the illustrated circuit? EL-0030 A. The field rheostat is used for manual voltage control. B. if the generator is flat compounded then the field rheostat needs to be adjusted up at full load to compensate for excessive voltage droop. C. this is a direct current elevator control with the lower and raise corresponding with the direction that the elevator will travel. D. the motor will tend to act like a series motor and overspeed with the controller in the full raise position.  

1 Answer

Answer :

Answer: A

Related questions

Description : Moving the rheostat handle shown in the illustration, that is used to control a DC generator, towards the 'raise' direction will increase the _____________. EL-0030 A. field resistance B. armature resistance C. armature speed D. line voltage

Last Answer : Answer: D

Description : If field excitation is suddenly lost to an alternator operating in parallel, that alternator will _____________. A. supply excessive current to the bus B. operate at the same load, but with reduced voltage C. lose its load and tend to overspeed D. become overloaded and slow down

Last Answer : Answer: C

Description : The kilowatt load can be adjusted on a paralleled generator by using the _____________. A. field rheostat B. governor control C. automatic voltage regulators D. hand tachometer

Last Answer : Answer: B

Description : Low voltage releases as used in some shipboard motor starter and control equipment will have which of the following characteristics? A. They trip circuit contactors when the motor starts to overspeed. B. ... coil of the starter. D. They allow the motor to restart upon restoration of normal voltage.

Last Answer : Answer: D

Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed

Last Answer : Answer: D

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : If a unloaded shunt motor's field were weakened by rheostat resistance or by an open circuit, the motor would _________. A. overspeed due to reduced CEMF B. stop because of low flux C. continue to run at base speed D. slow down and overheat

Last Answer : Answer: A

Description : The device labeled 'REG SW' in the illustration is used to ___________. EL-0003 A. shift from the automatic voltage regulator to the manual voltage regulator B. shift the governor control from manual to ... device 'REG ADJ' or device 'MAN ADJ' D. supply regulated control power to the switchboard

Last Answer : Answer: A

Description : In the illustrated motor controller, the motor fails to start. A voltmeter reading between 1 and 6 reads line voltage, while the voltmeter reading between 2 and 6 reads 0 VAC. The problem is __________. EL- ... in the 'M' coil, 'Ma' contact/start switch or overload contacts D. fuse '10a' is blown

Last Answer : Answer: B

Description : Which of the following statements is true regarding the illustrated circuit? El-0069 A. This full wave bridge should never be used aboard ship because the ground on lead 'A' will show on ... be direct current suitable for electronic circuits requiring voltage regulation. D. All the above are true.

Last Answer : Answer: B

Description : The governor control switch of an alternator is moved to the 'raise' position. This action will _____________. A. raise the no-load speed setting of the governor B. raise the percentage of speed droop C. lower the no-load speed setting of the governor D. lower the percentage of speed droop

Last Answer : Answer: A

Description : The frequency of an AC generator is adjusted by means of the ____________. A. main alternator field rheostat B. exciter field rheostat C. prime mover governor control D. equalizing reactor

Last Answer : Answer: C

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : Which of the terms listed best describes a compound-wound DC generator having a higher voltage at no load than at full load? A. Flat compounded B. Over compounded C. Under compounded D. Terminal compounded

Last Answer : Answer: C

Description : A compound generator has a no-load voltage of 250 volts and a full-load voltage of 230 volts, and therefore, is considered to be _____________. A. flat compounded B. over compounded C. under compounded D. terminal compounded

Last Answer : Answer: C

Description : If the electricity represented by the wave form in 'B' were applied to the left side of the illustrated circuit, the output on the right side would be ____________. EL-0064 A. direct current with the ... lower lead D. clipped to a value equal to the square root of 3 times the input voltage value

Last Answer : Answer: C

Description : A dc cumulatively compounded motor delivers rated load torque at rated speed. If series field is short circuited, then the armature current and speed will a) Both increases b) Both decreases c) Increases and decreases d) Decreases and increases

Last Answer : Ans: Both increases

Description : The electrical diagram shown in the illustration represents a ___________. EL-0054 A. series-wound motor B. shunt-wound motor C. compound-wound motor D. flat-compounded motor

Last Answer : Answer: C

Description : In the illustrated test, if the lamp fails to light on any of the three windings then _________. EL-0027 A. all three windings are grounded and the motor should be sent out for repair B. ... the motor controller and the controller should be checked D. the test should be redone at a higher voltage

Last Answer : Answer: C

Description : Refering to the illustrated schematic diagram, which of the following statements is true when the motor is running in the forward direction? EL-0011 A. Normally-open contacts '4-5' are closed. B. Current ... switch. C. Normally-closed contacts 'R' are open. D. The blowout coils must be closed.

Last Answer : Answer: B

Description : In the illustration, the component labeled 'EXC' is _______. EL-0003 A. a separate class II regulated DC generator for critical direct current loads B. a generator feeding the FLD ... to drive the governor for turbogenerator speed. D. the electronic driver for the switchboard metering circuits

Last Answer : Answer: B

Description : Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the __________. A. manual position B. bus neutral position C. raise voltage position D. transfer position

Last Answer : Answer: A

Description : If the supply voltage is 220 volts 60 Hz, what is the operating voltage of the motor controller circuitry illustrated? EL-0011 A. 110 volts DC B. 110 volts AC C. 220 volts DC D. 220 volts AC

Last Answer : Answer: D

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : When securing an AC generator, you should FIRST ___________. A. open the generator circuit breaker B. switch the voltage regulator to 'manual' C. decrease the field excitation to minimum D. reduce the load on the unit

Last Answer : Answer: D

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : If the driving torque, such as that produced by a diesel engine, creates pulsations when coupled with a synchronous generator operating in parallel; the generator rotor may be periodically pulled ... windings B. direct coupling C. increase governor speed droop D. decreasing governor speed droop

Last Answer : Answer: A

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : The illustrated circuit is a wheatstone bridge. If the meter 'G' reads 0 with the switch closed then ________. EL-0024 A. the current through R1 - R2 is equal to the current through R3 - Rx B. the voltage ... of E C. the resistance of Rx is equal to the resistance of R2 D. all the above are true

Last Answer : Answer: A

Description : The power factor at which a paralleled AC generator operates is usually adjusted by the _____________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: C

Description : The purpose of 'R6' in the winch circuit shown in the illustration is to _______________. EL-0102 A. maintain dry conditions within the winch brake box B. keep the series field current at ... to assist the winch in stopping D. limit the armature current during lowering operation with heavy loads

Last Answer : Answer: C

Description : The illustrated device is a _______. EL-0064 A. full wave bridge rectifier B. half wave bridge rectifier C. solid state voltage regulator D. direct current (DC) filter

Last Answer : Answer: A

Description : In the illustrated circuit, one advantage of the capacitor coupling over direct coupling is ____________. EL-0048 A. as the frequency decreased the capacitive reactance (Xc) increases B. the amplifier becomes ... of the signal while it isolates the biasing of each stage. D. good frequency response.

Last Answer : Answer: C

Description : If an AC generator experiences voltage failure, the cause may be _____________. A. an open in the field circuit B. the brushes shifting out of the neutral plane C. excessive locked-rotor current D. a rotating slip ring

Last Answer : Answer: A

Description : The purpose of resistor bank 'R1-R5' in the winch circuit shown in the illustration is to ______________. EL-0102 A. limit armature current in lower and 'series field' current in hoist to ... required speeds D. regulate the strength of the brake solenoid 'B1-B2' in both directions of operation

Last Answer : Answer: C

Description : The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ____________. A. droop B. drop C. dip D. regulation

Last Answer : Answer: C

Description : Loss of or weak residual magnetism in an alternator or generator can be corrected for by _________________. A. running the rotor in the opposite direction for 5 minutes B. allowing the generator ... rheostat fully counterclockwise D. using a storage battery or battery charger to 'flash' the field

Last Answer : Answer: D

Description : The 'function generator' of the control circuit illustrated _______________. EL-0095 A. can be programmed to produce a non-linear output for a linear input depending on operating conditions B. is used for ... which or how many engines are needed for a required vessel speed D. all of the above

Last Answer : Answer: A

Description : If a voltage of 132 VDC is applied to the illustrated circuit where the resistance is 12 ohms, then current will be ___________. EL-0018 A. 0.090 amps B. 1.090 amps C. 11 amps D. 144 milliamps

Last Answer : Answer: C

Description : As shown in the illustration, when the 'speed control' system is in 'SPLIT' _______________. EL-0096 A. Relays #1, #5 and #8 are not used B. the 'slew rated controller' is grounded through Relay ... E/P converters' are bypassed and air is fed directly to the governors via the 'load sharing valve'

Last Answer : Answer: C

Description : If reading the AC voltage from the line lead of a 440 VAC controller the range switch illustrated should be set to ___________. EL-0047 A. 1,000 V B. 250 V C. R X 10,000 D. Unable to safely read with this meter.

Last Answer : Answer: A

Description : A DC shunt generator has its field windings connected in _____________. A. series with the series windings B. parallel with the field rheostat C. series with the armature windings D. parallel with the armature windings

Last Answer : Answer: D

Description : A variable shunt, connected across the series field coils of a DC compound wound generator, to permit adjustment of the degree of compounding, is called a _____________. A. divider B. diverter C. converter D. rheostat

Last Answer : Answer: B

Description : Which of the following statements is true concerning the operation of two alternators in parallel? A. The cycles per second of each alternator are the same. B. Both alternator governors must be set ... be the same on each alternator. D. The load must always be divided equally between alternators.

Last Answer : Answer: A