If only one brush on a commutator is sparking excessively, you should look for _____________. A. a high commutator bar B. copper imbedded in the brush C. a loose commutator bar D. flux in the commutating zone

1 Answer

Answer :

Answer: B

Related questions

Description : In D.C. motor construction, the armature coils' ends are _______________. A. soldered to the commutator bar risers B. imbedded into core slots C. crimped together with brush pigtails D. spliced with the field windings

Last Answer : Answer: A

Description : Which of the listed conditions could cause a DC motor to have excessively hot windings and sparking at the brushes? A. Reversed interpole polarity B. High bar-to-bar voltage C. Loose brushes D. Excessive humidity

Last Answer : Answer: A

Description : Sparking at the brushes of a running motor could be an indication of _____________. A. normal operation B. a dirty commutator C. increased brush capacity D. water vapor absorption

Last Answer : Answer: B

Description : Temporary repairs to an open DC propulsion armature coil can be made by _____________. A. connecting the coil ends directly to a pair of negative brushes B. disconnecting coil ends, insulating ... C. grounding the coil ends and short circuiting the commutator bar D. removing the sparking brushes

Last Answer : Answer: B

Description : Modern DC generators are fitted with commutating poles to _____________. A. prevent motorizing B. reduce sparking C. reduce the load on the main poles D. reduce spring pressure on the brushes

Last Answer : Answer: B

Description : Due to which of the following factors the brush wear rate is altered ? (a) Speed of the machine (b) Contact pressure (c) Surface conditions of brush and commutator (d) Excessive sparking (e) All of the above

Last Answer : Ans: E

Description : In general, D.C. propulsion motor brush sparking can be caused by _______________. A. incorrect brush grade, pressure or position B. a concentric commutator C. a dark chocolate colored commutator D. all of the above

Last Answer : Answer: A

Description : The most effective method of locating a loose commutator bar in a D.C. motor is by _____________. A. visual inspection B. jiggling each by hand C. sounding each bar with a light weight hammer D. checking with a calibrated torque wrench

Last Answer : Answer: C

Description : Brushes in a generator must be positioned in the neutral plane to avoid sparking between the brushes and the _____________. A. yoke B. armature windings C. field pole windings D. commutator

Last Answer : Answer: D

Description : The purpose of the commutator and brushes on a DC generator is to _____________. A. transfer generated direct current voltage from the armature to the line B. convert the alternating voltage ... contact method to excite the field D. reduce sparking between the armature and the carbon brushes

Last Answer : Answer: B

Description : Sparking of D.C. motor brushes can be caused by __________. A. an open commutating winding B. many mechanical, electrical or operating faults C. an open interpole D. all of the above

Last Answer : Answer: B

Description : Basic electrical motor action depends on _______________. A. a conductor rotated within a magnetic field B. a current carrying conductor placed in a magnetic field C. the relative force of the commutator and commutating poles D. the relative force of the armature and interpoles

Last Answer : Answer: B

Description : Uneven wear of the commutator surface on a direct current propulsion motor can be caused by _____________. A. rapid change in load B. excessive operation at light load C. incorrect brush staggering D. unequal pole spacing

Last Answer : Answer: C

Description : A three-phase, squirrel cage, induction motor will run hot due to a/an ______________. A. improper brush position B. reversed commutating pole C. shorted stator D. high power factor

Last Answer : Answer: C

Description : An important factor in reducing D.C. motor commutator wear is _______________. A. keeping the ambient humidity as low as possible B. ensuring a very low brush current density C. establishing the copper oxide surface film D. all of the above

Last Answer : Answer: C

Description : Which of the listed faults cannot be eliminated, EXCEPT by turning or grinding a commutator with a rigidly supported tool? A. Sparking brushes B. Eccentricity C. High mica D. Blackened commutator

Last Answer : Answer: B

Description : The function of the commutator in a DC motor is to ________. A. reverse the flow of current through the armature B. reverse the flow of current in the field poles C. reduce the reluctance of the magnetic path through the motor D. shift the neutral running plane of the brushes to prevent sparking

Last Answer : Answer: A

Description : In an AC generator, direct current from a separate source is passed through the windings of the rotor _____________. A. by means of slip rings and brushes B. by means of a commutator C. by means of rotating bar magnet D. to minimize the danger of arc over

Last Answer : Answer: A

Description : A three-phase, squirrel cage, induction motor will run hot due to _____________. A. open stator coils B. high power factor C. dirty or corroded slip rings D. reversed commutating poles

Last Answer : Answer: A

Description : Sparking at the brushes of a DC propulsion motor can be the result of ____________. A. improper brush pressure B. improper brush seating C. reversed interpole polarity D. all of the above

Last Answer : Answer: D

Description : The armature cores of the D.C. motors are constructed with laminations to ___________. A. eliminate hysteresis B. minimize brush sparking C. reduce eddy current losses D. compensate for armature reaction

Last Answer : Answer: C

Description : Brush sparking during commutation may be caused by ________. A. eddy currents in the armature core B. laminations in the generator field pieces C. induced current opposite to coil inductance D. coil inductance discharge occurring at commutation

Last Answer : Answer: D

Description : The armature cores of the D.C. motors are constructed with laminations to ___________. A. eliminate hysteresis B. minimize brush sparking C. reduce eddy current losses D. compensate for armature reaction

Last Answer : Answer: C

Description : Insufficient brush pressure on a DC motor may cause _______. A. generator overload B. excess residual magnetism C. water vapor absorption D. sparking of the brushes

Last Answer : Answer: D

Description : The effect of carrying field excitation excessively high on a synchronous motor will result in a _____________. A. tendency for the motor to fall out of step B. tendency for the motor to overspeed C. tendency for the motor to overheat D. loss of motor speed regulation

Last Answer : Answer: C

Description : Relative to the direction of rotation, a D.C. motor commutating pole has the same polarity as the _____________. A. main pole following B. interpole following C. main pole preceding D. interpole preceding

Last Answer : Answer: C

Description : An AC circuit has capacitance arranged in series. If the line voltage remains constant, the capacitive reactance value can be varied by changing the _____________. A. line frequency B. resistance C. number of commutating poles D. number of interpoles

Last Answer : Answer: A

Description : If a D.C. motor hums, but does not run when energized, which of the listed conditions could exist? A. Incorrect lead connections B. Incorrect brush setting C. A dirty commutator D. All of the above are correct.

Last Answer : Answer: D

Description : D.C. motor brush adjustment includes attention to _________. A. angle with the commutator and clearance within the holder B. brush length and pigtail tightness C. grade of material and surface dirt conditions D. all of the above

Last Answer : Answer: D

Description : What causes sparking between the brushes and the commutator?

Last Answer : Improper commutation.

Last Answer : Sparking at the commutator of a D.C. motor may result in damage to commutator segments, damage to commutator insulation, increased power consumption.

Description : A shorted armature coil in a DC motor can be detected by _____________. A. sparking at the brushes B. shiny armature coil C. worn grooves in the armature D. undercut mica

Last Answer : Answer: A

Last Answer : In a universal motor, the most common cause of brush sparking is open armature winding, shorted armature winding, shorted field winding, high commutator mica.

Description : Etched or burned bands on the contact faces of the brushes in a direct current generator can be caused by ____________. A. high mica segments B. copper drag on the commutator C. brushes improperly positioned D. copper embedded in the brushes

Last Answer : Answer: C

Description : As shown in the illustration, part 'X' of the diagram is known as a/an _____________. EL-0052 A. commutator B. interpole C. starting pole D. auxiliary pole

Last Answer : Answer: B

Description : The most practical method used for resurfacing a ship's service motor commutator is to _____________. A. turn it down in the ship's lathe B. use a grinding rig C. use a hand stone D. burnish it with commutator stones

Last Answer : Answer: B

Description : A short in the shunt field of a DC motor is best located by _____________. A. visual inspection of the commutator B. applying AC voltage to each field coil and measuring the voltage drop across ... using a growler and hacksaw blade D. isolating each coil from the others and using a megohmmeter

Last Answer : Answer: B

Description : A flickering ground detection lamp on a DC system would indicate a _____________. A. multiple-ground condition in the distribution system B. ground in an armature coil of an operating machine C. ground in a motor accompanied with a short D. short between two adjacent bars of the generator commutator

Last Answer : Answer: B

Description : For routine cleaning of a commutator, you should apply _____________. A. course sandpaper in a slow back and forth motion across the commutator slots B. an emery cloth parallel to the axis of the machine C. a canvas wiper to the machine while running D. cotton swabs between the commutator bars

Last Answer : Answer: C

Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above

Last Answer : Answer: D

Description : Which of the listed conditions might contribute to very rapid wearing of a DC machine's commutator bars? A. A grounded commutator bar B. Using improper carbon brushes C. Aligning the front and rear mica V-rings improperly D. An open circuit in the armature

Last Answer : Answer: B

Description : An open in the armature of a DC motor is suspected, but is not found by visual inspection of the commutator. The next step in troubleshooting this problem is to ________________. A. conduct a ... windings C. conduct an insulation resistance test of the armature D. test the commutator for a ground

Last Answer : Answer: A

Description : On some diesel-electric ships, the DC propulsion motor will only attain half speed when the generator fields are fully excited. Speeds above this are obtained by _____________. A. rotating brush ... B. raising the generator engine speed C. lowering the generator engine speed D. decreasing excitation

Last Answer : Answer: B

Description : The function of a brush and commutator arrangement in a dc motor is to  (1) produce unidirectional torque (2) produce unidirectional current in the armature (3) help in changing the direction of rotation of the armature (4) reduce sparking

Last Answer : The function of a brush and commutator arrangement in a dc motor is to produce unidirectional torque

Description : In addition to undercutting the mica, proper maintenance of a D.C. motor's commutator includes _______________. A. side-cutting the copper segments and insulating the slots B. coating the copper surface with light machine ... in an oven at a maximum of 95°C for not over 8 hours D. all of the above

Last Answer : Answer: A

Description : Which of the following conditions indicates that a lead-acid battery is being charged too rapidly? A. Sparks occurring at the positive terminal. B. Unusually high electrolyte specific gravity. C. Low plate potentials being developed. D. Excessively high temperatures and gassing rates.

Last Answer : Answer: D

Description : A lead-acid battery cell sustaining a short circuit _______. A. will be indicated by lime accumulation on the terminal posts B. will have unusually high cell voltage C. will become excessively heated while being charged D. cannot be completely discharged under load

Last Answer : Answer: C

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : In D.C. motor construction, commutating windings are wound on _________________. A. opposite main poles B. interpoles C. adjacent main poles D. the rotor core

Last Answer : Answer: B