Define: (i) Commercial efficiency of a transformer and

 (ii) All day efficiency of a transformer.


1 Answer

Answer :

(i) Commercial Efficiency :

It is the ratio of output power in watt to the input power in watt.

image

(ii) All day efficiency of a transformer: It is the ratio of output energy in kWh to the input energy in kWh in the 24 hours of the day

image

Related questions

Description : Compare core type transformer and shell type transformer on the following parameters. (i) Types of winding used, (ii) Application

Last Answer : Ans:

Description : State any two conditions for parallel operation of 3-phase transformer.

Last Answer : Conditions for Parallel operation of 3 phase transformer 1) Voltage ratings of both the transformers must be identical. 2) Percentage or p.u. impedance should be equal in magnitude. 3) X/R ratio ... between primary & secondary voltages must be same. 6) Phase sequence on both sides must be same.

Description : A 50 KVA transformer has iron loss 2 kW on full load. Calculate its iron loss at 75% of full load.

Last Answer : Iron loss is dependent on voltage and independent of load. Hence iron loss at 75% of Load = Iron loss at full load = 2 kW

Description : State any four properties of Ideal transformer.

Last Answer : Properties of Ideal transformer: 1) No losses (iron and copper losses), hence no temperature rise. 2) No magnetic leakage i.e (Coefficient of coupling between primary and secondary windings is unity) 3) Zero winding ... drop i.e. E1 = V1, E2 = V2 5) Efficiency 100 %. 6) Regulation 0 %.

Description : Define transformation ratio in terms of current and voltage.

Last Answer : (i) Transformation Ratio (K) is defined as the ratio of the primary current to the secondary current.  (ii) Transformation Ratio (K) is defined as the ratio of the secondary voltage to the primary voltage.

Description : State any two applications of single phase autotransformer.

Last Answer : Applications of single phase auto transformers: 1) Give small boost to distribution cable to correct the voltage drop. 2) As auto transformer starter for induction motors. 3) As furnace supply ... . 5) In control equipment for single phase locomotives. 6) As dimmer in lighting circuits.

Description : Draw the connection diagram of long shunt differential D.C. compound generator.

Last Answer : Ans:

Description : Losses which occur in rotating electric machines and do not occur in transformers are?

Last Answer : Friction losses windage losses 

Description : In dc machines, the armature windings are placed on the rotor because of the necessity for  (1) electromechanical energy conversion (2) generation of voltage (3) commutation (4) development of torque

Last Answer : 3  Commutation

Last Answer : Satisfactory commutation of D.C. machines requires brushes should be of proper grade and size, brushes should smoothly run in the holders, smooth, concentric commutator properly undercut.

Last Answer : Brushes of D.C. machines are made of carbon.

Last Answer : Hopkinson's test on D.C. machines is conducted at full-load.

Last Answer : The purpose of retardation test on D.C. shunt machines is to find out stray losses.

Last Answer : In D.C. machines the residual magnetism is of the order of 2 to 3 percent.

Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Last Answer : The efficiency of transformer is Greater than electrical Machine because there is no rotational losses in transformer and there is no air gap losses in transformer so losses is less in transformer compare to electrical machine so efficiency is higher in case of transformer.

Description : 5 The efficiency of a transformer is maximum when A. It runs at half full load B. it runs at full load C. its Cu loss equal iron loss D. it runs over load

Last Answer : C. Its cu loss equal iron loss

Description : 74)Power transformers are generally designed to have maximum efficiency around A. No load B. Half load C. Near full load D. 10% overload

Last Answer : C. Near full load

Last Answer : Distribution transformers are generally designed for maximum efficiency around 50% load.

Last Answer : Power transformers are generally designed to have maximum efficiency around near full-load.

Description : The efficiency of two identical transformers under load conditions can be determined by?

Last Answer : The efficiency of two identical transformers under load conditions can be determined by back-to-back test.

Description : 78 Which type of winding is used in 3 phase shell type transformer? A. Circular type B. Sandwich type C. Cylindrical type D. Rectangular type

Last Answer : B. Sandwich type

Description : 73 The full load copper loss of a transformer is 1600W. At half-load the copper loss will be A. 6400W B. 1600W C. 800W D. 400W

Last Answer : D. 400W

Description : [23] Transformers are rated in KVA instead of KW because A. load power factor is often not known B. KVA is fixed whereas KW depends on load power factor C. Total transformer loss depends on volt ampere D. It has become customary

Last Answer : C. Total transformer loss depends on volt ampere

Description : Why a transformer requires cooling. What are the methods of cooling transformers?

Last Answer : Ans. Transformers requires cooling as they get heated up due to various losses taking place in the transformer. (like iron of copper losses) Following are the methods of cooling of transformer. a. Natural ... . Forced oil air Natural Cooling (OFAN). d. Forced oil and forced Air cooling (OFAF).

Description : Why circuit breaker connect b)w two transformer  (same rating

Last Answer : Because two transformers connection is in parallel to share the load if any transformer is receives the surge current because of the fault so to protect the other transformer from the fault. 

Last Answer : A common method of cooling a power transformer is oil cooling.

Last Answer : Harmonics in transformer result in increased core losses, increased I2R losses, and magnetic interference with communication circuits.

Description : Are we losing control over our life to machines?

Last Answer : That is up to you. You can or you can decide to not.

Description : Can anyone in the office machine business explain how click charges work?

Last Answer : can you give more specifics? Typically the contract would include a certain amt. of impressions (clicks) then any after that would be at a lesser rate.

Description : Heat Transfer Machines

Last Answer : Heat transfer machines are just the thing you need in order to do heat transfers on your clothing or whatever surface you want to decorate. In order for you to stick designs and precious stones on porous and ... is best. This will also give you an idea of what kind of designs you can choose from.

Description : List any four advantages and two disadvantages of 3 phase induction motor.

Last Answer : Advantages of 3 phase induction motor: 1) Simple in construction. 2) Economical in cost. 3) Requires very less maintenance. 4) High efficiency. 5) Low maintenace cost. 6) Self starting. 7 ... operated below its full load capacity. 6) It takes a large current from line at instant of starting.

Description : Explain how in a 3 phase induction motor to a rotating magnetic field is developed. 

Last Answer : Production of Rotating Magnetic Field in Three-phase Induction Motor: In three-phase induction motor, the three-phase stator windings are displaced in space by 120° and their three-phase currents are displaced ... time by 120°. Such fluxes give rise to the resultant rotating magnetic field.

Description : What type of motor is used for drilling machines?

Last Answer : universal motor also used in Handheld power tools, blowers, blenders, vacuum cleaners, polishers and kitchen appliances.universal motor is defined as a motor which may be operated either on direct or single phase AC supply at approximately the same speed and output

Description : Can you guys explain the advantages of frequency converter against the star delta or soft starter?

Last Answer : ¬Soft starters  A soft starter is, as you would expect, a device which ensures a soft starting of a motor. A softstarter has different characteristics to the other starting ... at rated current from zero to full speed. Frequency converters are becoming cheaper all the time.

Description : The inertia constants of two groups of machines which do not swing together are M1 and M2. The equivalent inertia constant of the system is

Last Answer : The inertia constants of two groups of machines which do not swing together are M1 and M2. The equivalent inertia constant of the system is M1M2/M1+M2

Description : For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester

Last Answer : For protection of rotating machines against lightning surges combination of lightning arrester and capacitor is used. 

Description : Laminated cores, in electrical machines, are used to reduce?

Last Answer : Laminated cores, in electrical machines, are used to reduce eddy current loss.

Description : Silicon steel is used in electrical machines because it has?

Last Answer : Silicon steel is used in electrical machines because it has low hysteresis loss.

Last Answer : For a D.C. machines laboratory following type of D.C. supply will be suitable induction motor D.C. generator set.

Last Answer : The speed control of universal motor used for sewing machines is by varying the resistance.

Last Answer : Exciters of synchronous machines are d.c. shunt machines.

Description : TRANSFORMERS MCQ

Last Answer : 101. A shell-type transformer has (a) high eddy current losses (b) reduced magnetic leakage (c) negligibly hysteresis losses (d) none of the above Ans: b 102. A transformer can have regulation closer to zero (a ... (6) much smaller (c) much higher (d) somewhat smaller (e) none of the above Ans: c

Description : What are the schedules of maintenance done on transformers?

Last Answer : Ans. Following are the schedules of maintenance on transformers. a. Daily maintenance. b. Monthly maintenance. c. Quarterly maintenance. d. Half yearly maintenance. e. Yearly maintenance. f. 5 Yearly maintenance.

Description : What are the loses in Transformers, Explain?

Last Answer : Ans. (1) Iron loses (2) Copper loses Iron Loss : Iron loss occurs in the transformers Iron core due to hysteresis and eddy currents taking place. They are almost fixed irrespective of ... losses in the primary and the secondary windings of the transformer which with the loading of transformer.

Description : Classify the transformers based on the construction, frequency and power.

Last Answer : Classification of Transformer Based On: i) Construction: Shell type, Core type, Berry type ii) Change in voltage level: Step-Up, Step-Down, iii) Number of phases: Single phase, Three phase iv) ... Control vi) Cooling: Self-cooled, Air-cooled, Forced-air cooled, Oil-cooled, Forced-oil cooled. 

Description : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Last Answer : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Description : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 

Last Answer : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 33%

Description : Core type transformers are popular in___________.  (A) High voltage applications (B) Low voltage applications (C) All of the above (D) None of the above

Last Answer : Core type transformers are popular in High voltage applications

Description : In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

Last Answer : In a transmission line if booster transformers are to be used, preferred location will be At the intermediate point