Compare core type transformer and shell type transformer on the following parameters. (i) Types of winding used, (ii) Application

1 Answer

Answer :

Ans:

image

Related questions

Description : Define: (i) Commercial efficiency of a transformer and  (ii) All day efficiency of a transformer.

Last Answer : (i) Commercial Efficiency : It is the ratio of output power in watt to the input power in watt. (ii) All day efficiency of a transformer: It is the ratio of output energy in kWh to the input energy in kWh in the 24 hours of the day

Description : State any two conditions for parallel operation of 3-phase transformer.

Last Answer : Conditions for Parallel operation of 3 phase transformer 1) Voltage ratings of both the transformers must be identical. 2) Percentage or p.u. impedance should be equal in magnitude. 3) X/R ratio ... between primary & secondary voltages must be same. 6) Phase sequence on both sides must be same.

Description : A 50 KVA transformer has iron loss 2 kW on full load. Calculate its iron loss at 75% of full load.

Last Answer : Iron loss is dependent on voltage and independent of load. Hence iron loss at 75% of Load = Iron loss at full load = 2 kW

Description : State any four properties of Ideal transformer.

Last Answer : Properties of Ideal transformer: 1) No losses (iron and copper losses), hence no temperature rise. 2) No magnetic leakage i.e (Coefficient of coupling between primary and secondary windings is unity) 3) Zero winding ... drop i.e. E1 = V1, E2 = V2 5) Efficiency 100 %. 6) Regulation 0 %.

Description : State any two applications of single phase autotransformer.

Last Answer : Applications of single phase auto transformers: 1) Give small boost to distribution cable to correct the voltage drop. 2) As auto transformer starter for induction motors. 3) As furnace supply ... . 5) In control equipment for single phase locomotives. 6) As dimmer in lighting circuits.

Description : Define transformation ratio in terms of current and voltage.

Last Answer : (i) Transformation Ratio (K) is defined as the ratio of the primary current to the secondary current.  (ii) Transformation Ratio (K) is defined as the ratio of the secondary voltage to the primary voltage.

Description : Draw the connection diagram of long shunt differential D.C. compound generator.

Last Answer : Ans:

Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Description : Losses which occur in rotating electric machines and do not occur in transformers are?

Last Answer : Friction losses windage losses 

Description : 78 Which type of winding is used in 3 phase shell type transformer? A. Circular type B. Sandwich type C. Cylindrical type D. Rectangular type

Last Answer : B. Sandwich type

Description : In dc machines, the armature windings are placed on the rotor because of the necessity for  (1) electromechanical energy conversion (2) generation of voltage (3) commutation (4) development of torque

Last Answer : 3  Commutation

Last Answer : Satisfactory commutation of D.C. machines requires brushes should be of proper grade and size, brushes should smoothly run in the holders, smooth, concentric commutator properly undercut.

Last Answer : Brushes of D.C. machines are made of carbon.

Last Answer : Hopkinson's test on D.C. machines is conducted at full-load.

Last Answer : The purpose of retardation test on D.C. shunt machines is to find out stray losses.

Last Answer : In D.C. machines the residual magnetism is of the order of 2 to 3 percent.

Description : Core type transformers are popular in___________.  (A) High voltage applications (B) Low voltage applications (C) All of the above (D) None of the above

Last Answer : Core type transformers are popular in High voltage applications

Last Answer : The efficiency of transformer is Greater than electrical Machine because there is no rotational losses in transformer and there is no air gap losses in transformer so losses is less in transformer compare to electrical machine so efficiency is higher in case of transformer.

Description : 73 The full load copper loss of a transformer is 1600W. At half-load the copper loss will be A. 6400W B. 1600W C. 800W D. 400W

Last Answer : D. 400W

Description : [23] Transformers are rated in KVA instead of KW because A. load power factor is often not known B. KVA is fixed whereas KW depends on load power factor C. Total transformer loss depends on volt ampere D. It has become customary

Last Answer : C. Total transformer loss depends on volt ampere

Description : 5 The efficiency of a transformer is maximum when A. It runs at half full load B. it runs at full load C. its Cu loss equal iron loss D. it runs over load

Last Answer : C. Its cu loss equal iron loss

Description : Why a transformer requires cooling. What are the methods of cooling transformers?

Last Answer : Ans. Transformers requires cooling as they get heated up due to various losses taking place in the transformer. (like iron of copper losses) Following are the methods of cooling of transformer. a. Natural ... . Forced oil air Natural Cooling (OFAN). d. Forced oil and forced Air cooling (OFAF).

Description : Why circuit breaker connect b)w two transformer  (same rating

Last Answer : Because two transformers connection is in parallel to share the load if any transformer is receives the surge current because of the fault so to protect the other transformer from the fault. 

Last Answer : A common method of cooling a power transformer is oil cooling.

Last Answer : Harmonics in transformer result in increased core losses, increased I2R losses, and magnetic interference with communication circuits.

Description : State the function of following parts of DC motor : i) Yoke ii) Poles iii) Field winding iv) Commutator. 

Last Answer : Function : i) Yoke: The yoke serves the following two purposes. i) It supports the other components such as poles and provides mechanical protection for whole machine. ii) It forms a part of ... one pole to another and thus to help the motor to develop a continuous and unidirectional torque  

Description : What type of motor is used for drilling machines?

Last Answer : universal motor also used in Handheld power tools, blowers, blenders, vacuum cleaners, polishers and kitchen appliances.universal motor is defined as a motor which may be operated either on direct or single phase AC supply at approximately the same speed and output

Last Answer : For a D.C. machines laboratory following type of D.C. supply will be suitable induction motor D.C. generator set.

Description : Compare core type and shell type transformer.

Last Answer : Shell Type Transformer Core Type Transformer The core surround the windings  The Winding surround the core Magnetic Flux is distributed into 2 paths  Magnetic Flux has only ... in Weight  Less in Weight  It has two windows opening  It has one window opening

Description : Are we losing control over our life to machines?

Last Answer : That is up to you. You can or you can decide to not.

Description : Can anyone in the office machine business explain how click charges work?

Last Answer : can you give more specifics? Typically the contract would include a certain amt. of impressions (clicks) then any after that would be at a lesser rate.

Description : Heat Transfer Machines

Last Answer : Heat transfer machines are just the thing you need in order to do heat transfers on your clothing or whatever surface you want to decorate. In order for you to stick designs and precious stones on porous and ... is best. This will also give you an idea of what kind of designs you can choose from.

Description : List any four advantages and two disadvantages of 3 phase induction motor.

Last Answer : Advantages of 3 phase induction motor: 1) Simple in construction. 2) Economical in cost. 3) Requires very less maintenance. 4) High efficiency. 5) Low maintenace cost. 6) Self starting. 7 ... operated below its full load capacity. 6) It takes a large current from line at instant of starting.

Description : Explain how in a 3 phase induction motor to a rotating magnetic field is developed. 

Last Answer : Production of Rotating Magnetic Field in Three-phase Induction Motor: In three-phase induction motor, the three-phase stator windings are displaced in space by 120° and their three-phase currents are displaced ... time by 120°. Such fluxes give rise to the resultant rotating magnetic field.

Description : Can you guys explain the advantages of frequency converter against the star delta or soft starter?

Last Answer : ¬Soft starters  A soft starter is, as you would expect, a device which ensures a soft starting of a motor. A softstarter has different characteristics to the other starting ... at rated current from zero to full speed. Frequency converters are becoming cheaper all the time.

Description : The inertia constants of two groups of machines which do not swing together are M1 and M2. The equivalent inertia constant of the system is

Last Answer : The inertia constants of two groups of machines which do not swing together are M1 and M2. The equivalent inertia constant of the system is M1M2/M1+M2

Description : For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester

Last Answer : For protection of rotating machines against lightning surges combination of lightning arrester and capacitor is used. 

Description : Laminated cores, in electrical machines, are used to reduce?

Last Answer : Laminated cores, in electrical machines, are used to reduce eddy current loss.

Description : Silicon steel is used in electrical machines because it has?

Last Answer : Silicon steel is used in electrical machines because it has low hysteresis loss.

Last Answer : The speed control of universal motor used for sewing machines is by varying the resistance.

Last Answer : Exciters of synchronous machines are d.c. shunt machines.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Description : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians (A) Armature amp-conductors × (θ/360o) (B) Armature amp-turns × (θ/360o) (C) Armature amp-conductors × (1/4 - θ/360o) (D) Armature amp-conductors × (1/8 - θ/360o)

Last Answer : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians Armature amp-conductors × (1/8 - θ/360o)

Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Last Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Description : In case of conductively compensated D.C. series motors, the compensating winding is provided?

Last Answer : In case of conductively compensated D.C. series motors, the compensating winding is provided in series with armature winding.

Description : 74)Power transformers are generally designed to have maximum efficiency around A. No load B. Half load C. Near full load D. 10% overload

Last Answer : C. Near full load