Write any two applications of Instrumentation System.

1 Answer

Answer :

 Instrumentation is used to measure many parameters (physical values). These parameters include:

 Pressure,either differential or static

 Flow

 Temperature

 Levels of liquids, etc.

 Density

 Viscosity

 Ionising radiation

 Frequency

 Current

 Voltage

 Inductance

 Capacitance

 Resistivity

 Chemical composition

 Chemical properties

 Position

 Vibration

Related questions

Description : Draw the block diagram of instrumentation system and explain function of each block. 

Last Answer : Functions of each block: Primary sensing element: This first receives energy from the measured medium and produces an output depending on measured quantity. Variable conversion element: Converts ... indication of a pointer moving a scale or the recording of a pen Moving over chart.

Description : Give any two applications of LED and LCD each. 

Last Answer : Two applications of LED (1) As an indicators and small display. (2) In digital thermometer, pulse rate meter. (3) In patient monitoring. Two applications of LCD (1) In video games (2) In calculators (3) In test equipments (4) In gauges and counters

Description : Draw block diagram of spectrum analyser, State applications of spectrum analyser.

Last Answer : Block Diagram: Applications: 1. Spectrum analyzer is a very important item of test equipment for someone designing or repairing electronic equipment that uses radio frequency signals. 2. Its ... of the dominant frequency within a signal 8. Used to measure the properties of RF devices

Description : Draw block diagram of DSO . State applications of DSO

Last Answer : Applications of DSO : 1. It can be used to measure both AC and DC voltages and currents. It can also calculate RMS value, peak value, peak to peak value etc. 2. It ... . 5. It can be used to determine the modulation characteristics and detect the standing waves of transmission lines.

Description : State applications of digital frequency meter.

Last Answer : 1. For testing radio equipment 2. Measuring the temperature, pressure, and other physical values. 3. Measuring vibration, strain 4. Measuring transducers

Description : State any four applications of spectrum analyzer.

Last Answer : Applications: 1. Spectrum analyzer is a very important item of test equipment for someone designing or repairing electronic equipment that uses radio frequency signals. 2. Its key factor is that it is ... of the dominant frequency within a signal 8. Used to measure the properties of RF devices

Description : List four applications of CRO.

Last Answer : Applications of CRO: 1. It is used in laboratory for measurement of AC/DC voltage, current, frequency, phase and study nature of waveform. 2. It is used in TV receiver for creation of ... modulation percentage of modulated wave. 10. It is also used to check radiation pattern generated by antenna.

Description : List four applications of digital multimeter.

Last Answer : Applications : 1. It is used continuity test. 2. It is used to check diode 3. It is used to check transistor 4. It is used to measure voltage, current & resistance.

Description : List applications of ohmmeter.

Last Answer : 1. The ohmmeter is a meter for measuring electrical resistance in ohm. 2. It is used as Megger to measure high resistance. 3. It is used to test the power circuits.

Description : Explain Piezo-electric transducer with diagram. State its applications, advantages and disadvantages.

Last Answer : Explanation: Principle of operation: When a pressure or force or vibration applied to the crystalline material like quartz crystal or crystalline substances then an e.m.f. is generated across the ... destructive test (NDT) equipment's 4) Piezoelectric materials are use in ultrasonic transducers.

Description : Draw the sketch of electromagnetic flow meter and explain it. State advantages, disadvantages and applications of it.

Last Answer : Diagram:  Explanation: Electromagnetic flow meters works based on Faraday's Law of Electromagnetic Induction. According to this principle, when a conductive medium passes through a magnetic ... water, chilled water. Used for flow measurement of Corrosive liquids, slurries and pastes.

Description : List the applications of DAS. 

Last Answer : Applications of DAS: (I) In Aerospace (II) In biomedical (III) Telemetry industries (IV) When physical quantity being monitored

Description : Write objective of Data acquisition system.

Last Answer : Objectives of Data Acquisition System: It must monitor the complete plant operation to maintain online optimum and safe operations. It must provide an effective human communication system and be able to identify problem ... data. It must be reliable, and not have a down time greater than 0.1%.

Description : Draw the construction of CRT. Write two materials used for CRT display screen. 

Last Answer : Two materials used for CRT display screen: The role of this part is to display where the electrons are hitting the CRT. It is a screen coated with a material that emits light when struck by electrons. Zinc sulphide or Phosphorus are two commonly used materials. 

Description : Explain measurement of phase and frequency using Lissajous pattern. Write the formula for each one.

Last Answer : Phase measurement of Lissajous pattern: The phase measurement can be done by using Lissajous figures. The CRO is set to operate in the X- Y mode, then the display obtained on the screen of a ... or sub- multiple of the unknown frequency.  The Lissajous pattern appears stationary.     

Description : Explain the electro-magnetic flow meter with neat sketch and write it’s application. 

Last Answer : Electromagnetic flow meter: Principle of Operation: 1. The operation of an Electro-magnetic flow meter is based upon Faraday's Law, which states that the voltage induced across any conductor as it ... rates. It can be also used for measurement of flow rate of slurries, greasy materials.

Description : Draw and explain block diagram of Horizontal deflection system. 

Last Answer :  Trigger circuit: A trigger circuit is used to convert the incoming signal into trigger pulses, so that the input signal and the sweep frequency can be synchronized. The trigger circuit is ... before it is applied to the horizontal section. The block consists of a push- pull amplifier  

Description : Draw and describe horizontal deflection system in CRO 

Last Answer : Block Diagram: Explanation: Input from vertical amplifier is given to Horizontal system. Trigger circuit: a. A trigger circuit is used to convert the incoming signal into trigger ... : Horizontal amplifier amplifies the signal & passes the signal to horizontal plates of CRT. 

Description : Draw and describe general Data acquisition system . 

Last Answer : Data acquisition is the process of sampling signals that measure real world physical conditions and converting the resulting samples into digital numeric values that can be manipulated ... are usually controlled by software programs developed using various general purpose programming languages

Description : Define signal conditioning system.

Last Answer : Signal conditioning is the manipulation of a signal in a way that prepares it for the next stage of processing. Many applications involve environmental or structural measurement, such as temperature and vibration, from sensors.

Description : Sketch Block diagram of vertical deflection system used in CRO.

Last Answer : Block diagram of vertical deflection system used in CRO

Description : Sketch and describe pressure measurement system for 800 mm pressure, that contain Bourdon tube and LVDT.

Last Answer : Diagram: Explanation: The pressure measurement using bourdon tube and LVDT is shown in above figure. In this the, the bourdon tube act as primary transducer and LVDT which follows ... This set up is used for measurement of pressure which is converted into electrical signal by LVDT.

Description : Draw block diagram of function generator and list two specifications of it. 

Last Answer : Specifications: 1. Output- Square wave , sine wave, Triangular, TTL pulse 2. Frequency Ranges- 0.1 Hz to 11 MHz, up/down range switchable in eight decade steps 3. Dial Range-1 to 11 calibrated 0.1 to 1 uncalibrated 4. Pulse and Ramp Aspect Ratio-95:5

Description : State two uses of logic analyser. 

Last Answer : 1. Real time application 2. Troubleshooting and analysis of digital systems 3. Compatible with printer using RS 232 and IEEE 488 interface 4. Testing the IC s to detect defect before constructed. ... Industries. 7. In various software industries. 8. To find fault in Bio- medical instruments. 

Description : Draw block diagram of successive approximation digital voltmeter. State its two advantages and two disadvantages

Last Answer : Block diagram Or Advantages: o It is economical method of analog to digital conversion. o The resolution is up to 5 important digits are obtained. Disadvantages: o ... depends on which type of switches are used. o The conversion time required for digital to analog converter.

Description : List four dynamic characteristics of instruments. Define any two of them.

Last Answer : Dynamic characteristics of instruments are: 1. Speed of response 2. Fidelity 3. Lag 4. Dynamic error. Definition: 1. Speed of response: The rapidity with which instrument responds to make ... and the value indicated by the instrument if no static error is assumed is called as dynamic error.

Description : List two advantages of PMMC instrument.

Last Answer : 1. It has uniform scale. 2. Power consumption is low 3. It can be obtained in wide ranges. 4. High sensitivity & accuracy 5. It is unaffected by external magnetic field. 6. Additional damping device not required. 7. Hysteresis problem is not there.

Description : Define any two dynamic characteristics of measurements.

Last Answer : 1. Speed of response: The rapidity with which instrument responds to make changes in the measured quantity is called as speed of response. 2. Fidelity: The degree to which instrument indicates the ... the value indicated by the instrument if no static error is assumed is called as dynamic error.

Description : Define transducer. Give two examples of transducer.

Last Answer : It is a device which convert any form of physical energy in to electrical energy. Two examples of transducer (1) Strain gauge (2) Thermistor (3) Thermocouple (4) LVDT

Description : Draw block diagram of digital frequency meter in time mode and describe its operation.

Last Answer : OR Operation: The input signal is amplified and converted to a square wave by a Schmitt Trigger circuit. In this diagram the square wave is differentiated and clipped to ... thereby closing it. The decimal counter and display unit output correspond to the number of input pulses. 

Description : Draw block diagram of DMM. State its advantages.

Last Answer : Advantages of DMM: 1. DMM provides numerical readouts that eliminate observational errors. Thus providing better readability. 2. DMM offers better accuracy and versatility as compared to ... memory devices for further computations. 5. The decreased size of DMM increases the portability

Description : What is LCR meter? Draw digital LCR –Q meter block diagram.

Last Answer : An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component. Block diagram digital LCR –Q meter  

Description : Draw Q meter circuit of series connection and explain it.

Last Answer : Q meter circuit of series connection OR Explanation The Q meter works on series resonant. The resonance is the condition exists in the circuit when their inductance and capacitance reactance are ... . Hence E=Q Ec so ,the voltmeter is calibrated for finding the value of Q factor.  

Description : Draw block diagram of distortion factor meter and explain its operation.

Last Answer : Block Diagram Operation This meter consist following four sections 1. Impedance converter along with input circuit 2. Rejection amplifier 3. Metering circuit 4. Power circuit 1. ... of the total input voltage. 4. The power supply unit provides the supply for proper operation 

Description : Define wave analyser and state its need, Draw the block diagram of it. 

Last Answer : Wave analyzer:- Wave analyzer is an instrument which is used to measure the magnitude of the various harmonics of a complex waveform. It is an instrument that is designed to measure the relative amplitudes ... distortion and the system signal to noise ratio. Block Diagram of Wave analyser

Description : Draw block diagram of RF signal generator and explain its operation.

Last Answer : RF signal generator contains three other main sections: 1.OSCILLATOR CIRCUIT, 2. MODULATOR, 3. OUTPUT CONTROL CIRCUIT. The modulator modulates the RF signal of the ... . Metal shielding surrounds the unit to prevent signals from the oscillator from affecting the circuit under test

Description : State and describe different triggering available in CRO

Last Answer : A trigger is an external signal or input signal condition that initiates one or more instrument functions. Trigger settings include digital edges, software functions, and analog levels. This tutorial ... the external trigger input. The following figure shows an entering window trigger.  

Description : Draw and state how Aryton shunt type DC ammeter . State advantage of using Aryton shunt.

Last Answer : OR The Aryton shunt eliminates the possibility of having the meter in the circuit without a shunt. This advantage is gained at the price of slightly higher overall Aryton shunt ammeter. In this ... between shunts. 3. Another advantage is that it may be used as a wide range ammeter. 

Description : Explain sensitivity and loading effect in voltmeter.

Last Answer : Sensitivity: The sensitivity of a voltmeter is just its capability to detect voltage, usually meaning smaller and smaller voltages. When selecting a meter for a certain voltage measurement, it is ... called loading effect of the voltmeters. It is mainly caused due to low sensitivity instruments.

Description : What is video pattern generator? State its application.

Last Answer : A pattern generator provides video signals directly, and with RF modulation, on standard TV channels for alignment ,testing and servicing of TV receivers. The output signal designed to produce simple ... section checking 6. Trouble shooting video amplifier and using variable video output.

Description : Draw the basic block diagram of single trace CRO and describe the function of delay line.

Last Answer : Function of Delay line: This block is used to delay the signal for a period of time in the vertical section of CRT. The input signal is not applied directly to the vertical plates because the part ... when the delay time is not used. Therefore, the input signal is delayed by a period of time. 

Description : Derive the relation for deflection torque in PMMC instrument. 

Last Answer : Ans: The length of coil be l meter and width of coil be d meter. Assume I is the current flowing in the ciol having N turns. Assume B as the flux density in the air gap then F=BIL ... a direct indication of the current in the coil. The pointer deflection can therefore be used to measure current.

Description : Draw the construction and explain working principle of PMMC instruments

Last Answer : Working: When current passes through the coil a deflecting torque is produced. This deflecting torque is produced due to interaction between magnetic field produced by permanent magnet ... equilibrium; this is possible only when the controlling torque becomes equal to the deflecting torque 

Description : Define the following: 1) Speed of response 2) Lag 3) Fidelity 4) Dynamic Error. 

Last Answer : (1) Speed of Response: It is the rapidity with which an instrument responds to changes in the measured quantity.  (2) Lag : It is the retardation or delay in the response of an instrument ... with time and value indicated by instrument if no static error is assumed is called as dynamic error.

Description : Explain the concept of single beam dual trace CRO with its block diagram.

Last Answer : Diagram:   Explanation: The single beam dual trace CRO consists of one electron gun, an electronic switch which switches the two signals to a single vertical amplifier and a single pair of ... Amplifier are identical & have the same delay time, accurate X-Y measurements can be taken. 

Description : Explain the measurement of voltage and frequency using CRO.

Last Answer : Voltage Measurement: CRO displays the voltage signal as a function of time on its screen. The amplitude of that voltage signal is constant, but we can vary the number of divisions that cover the voltage ... /division nv is the number of divisions that cover the signal in vertical direction.

Description : Explain gross error, systematic error and random error.

Last Answer : 1) Gross Errors -These errors occur due to human mistakes while taking reading, handling instrument, incorrect setting or adjustment and improper used of instrument. The complete elimination of gross ... remain since the systematic and gross error are removed. Generally these errors are very small.

Description : How are instruments classified? Describe the different types.

Last Answer : The instruments are classified depending upon: a. Principle of operation: E.g.: Magnetic meter, induction meter. b. Permissible percentage error c. Depending upon application: E. ... measured by observing the output indicated by instrument. Example: Voltmeter, Thermometer, pressure guage.

Description : Define standards. State and explain classification of standards.

Last Answer : Standards:-Standard is a physical representation of a unit of measurement. A known accurate measure of physical quantity is termed as standard. These standards are used to determine ... used to check components and calibrating laboratory instruments to achieve good accuracy and better performance.

Description : Define signal generator and state its need.

Last Answer : Signal Generator: A signal generator is an electronic device that generates repeating or Non-repeating electronic signals in either the analog or the digital domain. Need: The generation of ... of various electronic systems and for replacing missing signals in systems being analysed for repair.