Diffecult questions

1 Answer

Answer :

No. Please send me

Related questions

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Last Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Description : In voltage source converter based HVDC transmission system the active power is controlled by changing (A) phase angle of the converter ac input voltage (B) supply frequency of the converter ac input voltage (C) magnitude of the converter ac input voltage (D) DC voltage at the inverter terminals

Last Answer : In voltage source converter based HVDC transmission system the active power is controlled by changing phase angle of the converter ac input voltage

Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Description : Generally in a power system network, the load is represented as a :  (A) Constant power in both load flow study and in stability study  (B) Constant power in load flow study and constant ... impedance in load flow study  (D) Constant impedance in both load flow study and in stability study

Last Answer : Generally in a power system network, the load is represented as a : Constant power in load flow study and constant impedance in stability study 

Description : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is

Last Answer : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is 25 x 25

Last Answer : The contacts of high voltage switches used in power system are submerged in oil. The main purpose of the oil is to extinguish the arc.

Description : The benefit of power factor correction in a power system is (A) lower power consumption (B) increased demand charge (C) reduced load carrying capabilities in existing lines (D) reduced voltage profile

Last Answer : The benefit of power factor correction in a power system is lower power consumption

Description : Power factor of the system is kept high?

Last Answer : Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Description : A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is (A) 300 W (B) 150 W (C) 45 W (D) 20 W

Last Answer : A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is 150 W

Description : Summerise the role of power system engineer.

Last Answer : Role of power system engineer:  i. On the planning side he or she has to make decisions on how much electricity to generate  ii. For operation of the power system he has to plan for ... for energy conservation and load management. viii. For solving the power system problems he has to update with

Description : State the functions of fuel system and exhaust system of a diesel power station.

Last Answer : Fuel system: It supplies fuel to engine for combustion purpose. It consists of Fuel Pump: - It supplies fuel to engine for combustion purpose. Strainer: - Are provided to remove suspended impurities and ... most of the noise. Chimney:- To exhaust gases in the atmosphere as high as possible. 

Description : Explain starting system in diesel electric power plant.

Last Answer : Starting system in Diesel Electric Power Plant: It includes Storage battery, compressed air tanks, self-starter etc. The purpose of engine starting system is to rotate the engine initially while ... as Ammeters, Voltmeters, Wattmeters, Thermometers, Pressure gauges, Visible and audible alarm etc.

Description : Explain fuel system and air intake system in diesel electric power plant.

Last Answer : Fuel system and air intake system in diesel electric power plant :  Fuel system: It consists of storage tank, strainers, fuel transfer pump and all day fuel tank. The fuel oil is supplied ... Filters are provided to remove dust particles from air which may act as abrasive in the engine cylinder.

Description : What is the choice of size and number of generator units in interconnected power system?

Last Answer : Choice of Size and Number of Generating Units: 1. The size/rating and number of generating units in such way that they approximately match with the load curve as closely as possible. 2. In ... , if power plant is connected to grid system then generating unit of higher capacity can be installed.

Description : The stability of the power system is not affected by  (1) generator reactance (2) line reactance (3) line losses (4) output torque

Last Answer : The stability of the power system is not affected by line losses

Description : A lightening arrester connected between the line and earth in a power system  (1) protects the terminal equipment against travelling surges (2) protects the transmission line against direct ... suppresses high frequency oscillations in the line (4) reflects back the travelling wave approaching it

Last Answer : A lightening arrester connected between the line and earth in a power system protects the terminal equipment against travelling surges

Description : If non-linear loads are connected to the power system, then (A) displacement power factor is same as the total power factor (B) displacement power factor is not equal to the total power ... factor is due to harmonic currents (D) total power factor is due to fundamental component of current

Last Answer : If non-linear loads are connected to the power system, then displacement power factor is not equal to the total power factor

Description : steady-state stability of a power system is improved by

Last Answer : steady-state stability of a power system is improved by using double circuit line instead of single circuit line

Description : With fault clearing time, the transient stability of a power system

Last Answer : With fault clearing time, the transient stability of a power system decreases

Last Answer : Commonly used instruments in power system measurement are induction.

Last Answer : The steady state stability of the power system can be increased by connecting lines in parallel.

Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Description : What is sag in power system?

Last Answer : Sag is a catenary curve in between two points of supporters.and also we can say the lowest point of the conductor in between the two points of supporters. 

Description : What are interconnected power system?

Last Answer : Interconnected power systems are those which connect different geographic regions. In Australia we have a National Electricity Grid which connects 6 states. Transfers of power occur between the states depending ... make more profit from this.National-Electricity-Market-Fact-Sheet.pdf (0,9 MB)

Description : What is meant by feeder in power system?

Last Answer : A feeder line is a peripheral route or branch in a network which connects smaller or more remote nodes with a route or branch carrying heavier traffic. The term is applicable to any system based on a hierarchical network.

Description : What are the components of a power system?

Last Answer : generator Traansformer Conductors Insulators

Description : A series combination of resistance 100 ohm and capacitance 50µf is connected in series to a 230 V, 50HZ supply. Calculate (i) Capacitive reactance (ii) Current (iii) Power factor (iv) Power consumed 

Last Answer : For RC series circuit

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Description : The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

Last Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Description : A 3 -phase, fully controlled, converter is feeding power into a DC load at a constant current of 150 A, the rms value of the current flowing through each thyristor of the converter is

Last Answer : Please show the solution for this question

Description : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

Last Answer : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is 22.0 mm

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : What is the power factor of purely resistive circuit.

Last Answer : Unity that is 1

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Description :  A single-phase transmission line of impedance j 0.8 ohm supplies a resistive load of 500 A at 300 V. The sending end power factor is?

Last Answer :  A single-phase transmission line of impedance j 0.8 ohm supplies a resistive load of 500 A at 300 V. The sending end power factor is 0.6 lagging.

Description : Phase margin is the amount of angle to make the system  (1) Oscillatory (2) Stable (3) Unstable (4) Exponential

Last Answer : Phase margin is the amount of angle to make the system Unstable 

Description : If resistance is 8 Ohm and current is 16 ampere then what will be the voltage and power?

Last Answer : 128 volts ,2048 watts

Description : When a V-V three phase transformer system is converted into a Δ-Δ system, increase in capacity of the system is (A) 86.6% (B) 50% (C) 57.7% (D) 73.2%

Last Answer : When a V-V three phase transformer system is converted into a Δ-Δ system, increase in capacity of the system is 73.2%

Description : The product of apparent power and cosine of the phase angle between circuit voltage and current is?

Last Answer : In parllpar reasonans RLC circuit the current is

Description : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Last Answer : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Description : write short notes on single phase system.

Last Answer : A "phase" in an electrical system is often referred to as the waveform (may be voltage or the current) of the power supply. The waveform in an AC system is typically ... domestic household or commercial supplies and street lighting. Industrial supplies requires three phase electrical supply .

Description : A Unified Power Flow Controller (FACTS controller) is a voltage source converter based (A) Inter-phase power controller (B) Static Compensator (C) Combination of series and shunt compensators (D) Solid-state series compensator

Last Answer : A Unified Power Flow Controller (FACTS controller) is a voltage source converter based Combination of series and shunt compensators

Description : Why the power factor of semiconverter is better than full converter?

Last Answer : Power factor of semiconverter is better than full converter

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : Minimum voltage regulation occurs when the power factor of the load is?

Last Answer : Minimum voltage regulation occurs when the power factor of the load is leading.

Description : In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

Last Answer : In an alternator, at lagging power factor the generated voltage per phase as compared to that at unity power factor must be more than terminal voltage.

Description : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

Last Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V