Capacitive reactance
Last Answer : Capacitive reactance formula
Show More
72 views
1 answer
asked
Jun 11, 2019
by
anonymous

Parallel Reactance and Resistance Example 1
Last Answer : Parallel Reactance and Resistance Example 1
Show More
150 views
2 answers
asked
May 30, 2019
by
anonymous

AC Circuits with Resistance but No Reactance
Last Answer : AC Circuits with Resistance but No Reactance AC Circuits with Resistance but No Reactance Series resistances let two resistances R 1 and R 2 are connected in series as shows in figure and there ... voltage. Voltage V A is common to both the branch hence voltage V A is common reference.
Show More
102 views
1 answer
asked
May 26, 2019
by
anonymous

Capacitive reactance is more when?
Last Answer : Capacitive reactance is more when capacitance is less and frequency of supply is less.
Show More
161 views
1 answer
asked
Mar 24, 2018
by
anonymous
.jpg)
What is the inverse of reactance?
Last Answer : Inverse of reactance is Susceptance .Unit of Susceptance is Siemens.
Show More
141 views
1 answer
asked
Jan 7, 2018
by
anonymous

what is the reciprocal of reactance?
Last Answer : reciprocal of reactance is susceptance.
Show More
459 views
1 answer
asked
Sep 30, 2017
by
anonymous

Define impedance diagram and reactance diagram.
Last Answer : Impedance diagram: Impedance diagram is the simplified equivalent circuits of single line or one line diagrams of power system in which all components are represented by their equivalent circuit. ... machines are neglected and is used only for fault current calculation is called reactance diagram.
Show More
242 views
1 answer
asked
May 6, 2020
by
anonymous

What do you mean by exciting resistance and exciting reactance?
Last Answer : At no-load, a transformer behaves as a highly inductive load connected to the system which contains some resistance and inductance in parallel. The resistance is called exciting resistance R0 = V1/I w and reactance is called exciting reactance, X0 = V1/I mag
Show More
183 views
2 answers
asked
Apr 28, 2020
by
anonymous
.jpg)
If the % reactance upto the fault point is 20%, then the short circuit current will be
Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current
Show More
3.0k views
1 answer
asked
May 8, 2018
by
anonymous

A single phase transformer has resistance and reactance of 0.2 pu and 0.6 pu respectively. Its pu voltage regulation at 0.8 pf lagging would he
Last Answer : A single phase transformer has resistance and reactance of 0.2 pu and 0.6 pu respectively. Its pu voltage regulation at 0.8 pf lagging would he 0.52
Show More
367 views
1 answer
asked
May 3, 2018
by
anonymous
.jpg)
Consider the following statements. Which of these statements are correct ? (1) Reactance relays are preferred for ground fault relaying (2) Impedance relays are most suitable for:protecting long transmission lines (3) Mho relays are best ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)
Last Answer : Consider the following statements. Which of these statements are correct ? (1) Reactance relays are preferred for ground fault relaying (2) Impedance relays are most suitable for:protecting long transmission lines (3) Mho relays are ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)
Show More
130 views
1 answer
asked
Apr 29, 2018
by
anonymous

Reactance relay is normally preferred for protection against
Last Answer : Reactance relay is normally preferred for protection against earth faults
Show More
120 views
1 answer
asked
Apr 29, 2018
by
anonymous

Ratio of the rotor reactance X to the rotor resistance R for a two-phase servo motor (A) is equal to that of a normal induction motor (B) is less than that of a normal induction motor (C) ... than that of a normal induction motor (D) may be less or greater than that of a normal induction motor
Last Answer : C
Show More
582 views
2 answers
asked
Apr 28, 2018
by
anonymous

A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is (A) 0.85 Ω (B) 3.63 Ω (C) 36.3 Ω (D) 252 Ω
Last Answer : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is 3.63 Ω
Show More
288 views
1 answer
asked
Apr 28, 2018
by
anonymous

A reactance relay is (A) Voltage restrained directional relay (B) Directional restrained over-current relay (C) Voltage restrained over current relay (D) Directional restrained over voltage relay
Last Answer : A reactance relay is Directional restrained over-current relay
Show More
147 views
1 answer
asked
Apr 28, 2018
by
anonymous

Circuits with XL Alone
Last Answer : Circuits with XL Alone X L values in series let two inductive reactances X L 1 and X L 2 are connected in series and has value 50 ohm and 50 ohm respectively. 100 volts A C ... phasor. And it is taken horizontal. Phase angle between inductive current and voltage is same 90 degree.
Show More
82 views
1 answer
asked
May 26, 2019
by
anonymous

Define resistivity. State its unit.
Last Answer : Resistivity can be defined as the resistance of a conducting material per unit length with unit area of cross section. Its unit is ohm/meter
Show More
62 views
1 answer
asked
Aug 4, 2019
by
anonymous

What is the smallest unit of a compound with the same chemical characteristics?
Last Answer : The molecule is the smallest unit of a compound with the same chemical characteristics.
Show More
261 views
1 answer
asked
Jun 29, 2019
by
anonymous

THE UNIT OF RELUCTANCE IS
Last Answer : The si unit of reluctance is Ampere-turn/weber
Show More
227 views
1 answer

Write the purpose of coal and ash handling unit. Also write different activities that arc carried out in this unit.
Last Answer : Purpose of coal and ash handling unit :- To transport coal from coal storage to power plant. A large quantity of ash about 10 to 30 % produced in furnace, the removal of ash from boiler furnace ... disposed off. Various methods of disposal of ash: Mechanical system. Pneumatic system.
Show More
56 views
1 answer
asked
Sep 8, 2018
by
anonymous

Define admittance and state its unit.
Last Answer : Admittance is defined as the ability of the circuit to carry (admit) alternating current through it. OR It is the reciprocal of impedance Z. i.e Admittance Y = 1/Z. Unit: Its unit is siemen (S) or mho (Ʊ).
Show More
222 views
1 answer
asked
Sep 7, 2018
by
anonymous

What is the SI unit of conductivity ?
Last Answer : The SI unit of conductivity Siemens/m.
Show More
79 views
1 answer
asked
Sep 2, 2018
by
anonymous

Which unit holds data permanently? (A) Input unit (B) Secondary storage unit (C) Output Unit (D) Primary Memory Unit
Last Answer : Which unit holds data permanently? (A) Input unit (B) Secondary storage unit (C) Output Unit (D) Primary Memory Unit
Show More
170 views
1 answer
asked
May 8, 2018
by
anonymous

The unit heat rate characteristic of a thermal power unit shows : (A) Heat input per kWh of output versus the megawatt output of unit (B) Heat input per kW of output versus the megawatt output ... hour output of unit (D) Heat input per kW of output versus the megawatt hour output of unit
Last Answer : The unit heat rate characteristic of a thermal power unit shows : Heat input per kWh of output versus the megawatt output of unit
Show More
80 views
1 answer
asked
Apr 30, 2018
by
anonymous

Which of the following is the SI unit for admittance? A) Ohm B) Henry C) Farad D) Siemens
Last Answer : Which of the following is the SI unit for admittance? A) Ohm B) Henry C) Farad D) Siemens
Show More
227 views
1 answer
asked
Apr 29, 2018
by
anonymous

Which of the following is an example of SI derived unit? A) Capacitance (Farad) B) Time (second) C) Luminous intensity (Candela) D) All the above
Last Answer : Which of the following is an example of SI derived unit? A) Capacitance (Farad) B) Time (second) C) Luminous intensity (Candela) D) All the above
Show More
115 views
1 answer
asked
Apr 29, 2018
by
anonymous

Which of the following is a unit of magnetic flux? A) Weber B) Maxwell C) Both A and B D) None of these
Last Answer : Which of the following is a unit of magnetic flux? A) Weber B) Maxwell C) Both A and B D) None of these
Show More
103 views
1 answer
asked
Apr 29, 2018
by
anonymous

What is the SI unit for magnetic reluctance? A) Ampere B) Ampere-turns per weber C) Henry D) None of these
Last Answer : What is the SI unit for magnetic reluctance? A) Ampere B) Ampere-turns per weber C) Henry D) None of these
Show More
347 views
1 answer
asked
Apr 29, 2018
by
anonymous

The unit of reluctance is?
Show More
67 views
0 answers
asked
Mar 25, 2018
by
anonymous

The unit of retentivity is?
Last Answer : The unit of retentivity is weber/sq. m.
Show More
787 views
1 answer
asked
Mar 25, 2018
by
anonymous

The unit of magnetic flux is?
Last Answer : The unit of magnetic flux is weber.
Show More
76 views
1 answer
asked
Mar 25, 2018
by
anonymous

Last Answer : Flux density is denoted by B. And it is given as B = flux/ area Where, the unit of flux is Weber and unit of area is meter square. So the unit of flux density is weber per meter square which is also called as Tesla.
Show More
162 views
2 answers
asked
Sep 30, 2017
by
anonymous

Joule X second is the unit of?
Last Answer : Joule X second is the unit of power .
Show More
56 views
1 answer
asked
Sep 20, 2017
by
anonymous

Last Answer : Unit of power is Watt denoted by capital W .
Show More
94 views
1 answer
asked
Sep 20, 2017
by
anonymous

Last Answer : Unit of voltage is volt denoted by capital V .
Show More
104 views
1 answer
asked
Sep 20, 2017
by
anonymous

Last Answer : Unit of resistance is Ohm.
Show More
70 views
1 answer
asked
Sep 20, 2017
by
anonymous

Last Answer : Unit of work is Joule denoted by capital J .
Show More
71 views
1 answer
asked
Sep 20, 2017
by
anonymous
.jpg)
Last Answer : Unit of frequency is herzt
Show More
75 views
2 answers
asked
Sep 20, 2017
by
anonymous

Last Answer : Unit of inductance is Henry denoted by capital H .
Show More
94 views
1 answer
asked
Sep 20, 2017
by
anonymous

A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?
Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.
Show More
231 views
1 answer
asked
Mar 20, 2018
by
anonymous

How to Install a Home HVAC Unit
Last Answer : How to Install a Home HVAC Unit Installing a two zone home heating, ventilating and air-conditioning (HVAC) system is not for a casual do-it-yourselfer but most aspects of the system past ... have oriented their wire coloring system. It should be done carefully to prevent any possibility of harm.
Show More
9 views
1 answer
asked
May 14, 2021
by
anonymous
.jpg)
A) Watt B) Volts C) Farad D) Ampere
Last Answer : Correct answer: D) Ampere
Show More
2.6k views
1 answer
asked
Jun 28, 2019
by
anonymous
.jpg)
Options: A) WATT B) AMPERE C) VOLTS D) OHM
Last Answer : Correct Answer: A) WATT
Show More
75 views
1 answer
asked
Jun 28, 2019
by
anonymous

Define the following terms related to tariff: (i) Connected load (ii) Unit consumed (iii) Fixed charges (iv) Electricity Tax
Last Answer : (i) Connected load It is the sum of the power ratings (Watts or kW or MW) of all devices and machines existing (installed) in the premises of consumer. It is used to decide the ... a percentage of the total electricity bill which includes all amounts that go to the electricity supply agency.
Show More
433 views
1 answer
asked
Sep 22, 2018
by
anonymous

What does double integration of a unit step function lead to? A) A doublet B) A ramp C) An impulse D) A parabola
Last Answer : What does double integration of a unit step function lead to? A) A doublet B) A ramp C) An impulse D) A parabola
Show More
493 views
1 answer
asked
Jun 18, 2018
by
anonymous

Which of the following are components of Central Processing Unit (CPU)? (A) Arithmetic logic unit, Mouse (B) Arithmetic logic unit, Control unit (C) Arithmetic logic unit, Integrated Circuits (D) Control Unit, Monitor
Last Answer : Which of the following are components of Central Processing Unit (CPU)? (A) Arithmetic logic unit, Mouse (B) Arithmetic logic unit, Control unit (C) Arithmetic logic unit, Integrated Circuits (D) Control Unit, Monitor
Show More
1.2k views
1 answer
asked
May 8, 2018
by
anonymous

A control system having unit damping factor will give (1) Oscillatory response (2) Undamped response (3) Critically damped response (4) No response
Last Answer : 1
Show More
1.3k views
2 answers
asked
May 1, 2018
by
anonymous

The unit of speed regulation of a governor is : (A) Hz (B) Hz/MW (C) Hz/MVA (D) rpm/MVAR
Last Answer : The unit of speed regulation of a governor is : Hz/MW
Show More
226 views
1 answer
asked
Apr 29, 2018
by
anonymous

Unit commitment is a procedure in which : (A) Scheduling of total generation is done economically (B) Optimal combination of units in a system is chosen at any given time (C) ... are selected for financial economy (D) Most efficient machines are selected for minimum reactive power loss
Last Answer : Unit commitment is a procedure in which : Optimal combination of units in a system is chosen at any given time
Show More
79 views
1 answer
asked
Apr 29, 2018
by
anonymous

A second order system shows 100% overshoot in its unit step response. It can be categorized as (A) underdamped system. (B) overdamped system. (C) Critically damped system. (D) undamped system.
Last Answer : A second order system shows 100% overshoot in its unit step response. It can be categorized as undamped system.
Show More
102 views
1 answer
asked
Apr 28, 2018
by
anonymous