where the synchronous condenser are generally installed ?

1 Answer

Answer :

the synchronous condenser are generally installed at receiving end side of transmission line 

Like 0 like

Please log in or register to answer this question.

Related questions

92 views

Description : Can a synchronous condenser improve power factor?

Last Answer : Yes, synchronous condenser can improve power factor.

1 answer
110 views

Description : What is Synchronous condenser?

Last Answer : Synchronous condenser Big advantage of synchronous condenser is their large temporary overload capability and good harmonics performance. Synchronous condenser is ... ;voltage levels. Synchronous condenser have slow speed of response.

1 answer
101 views

Description : operating principle of condenser type microphone with neat diagram.

Last Answer : Principle: When sound pressure moves the diapharam in, the capacitance increases, and when it moves out, the capacitance decreases. The change in capacitance results in change in out put voltage of microphone. ... in volts.  Q= charge in coulombs  C= capacitance in farad Diagram: 

1 answer
96 views

Description : Explain working of superheater and condenser. 

Last Answer : Working of Super heater:  Super heater consist of group of tubes. Tubes are heated by absorbing temperature of flue gases passed over it . Superheated steam' is meant that steam which ... condensate is reused in boiler. This type of condenser is used for high capacity thermal power plant. 

1 answer
323 views

Description : State the function of cooling tower and condenser in thermal power station.

Last Answer : 1. Condenser:   Function of condenser is to convert exhaust steam again into water by reducing its temperature with the help of cold water. Also it reduces back pressure of steam turbine 2 ... tower : The function of cooling tower is to reduce the temperature of water coming from condenser.

1 answer
190 views

Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

1 answer
95 views

Last Answer : Synchronous motors are generally not self-starting because the direction of instantaneous torque reverses after half cycle.

1 answer
162 views

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

1 answer
21 views

Description : SYNCHRONOUS MOTORS MCQ

Last Answer : 101. In a synchronous motor it the back e.m.f. generated in the armature at noload is approximately equal to the applied voltage, then (a) the motor is said to be fully loaded (b) the torque ... square of the applied voltage (c) inversely proportional to applied voltage (d) none of the above Ans: a

3 answers
171 views

Description : List different starting methods of three phase synchronous motor. Explain any one of them.

Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

1 answer
525 views

Description : Draw and explain V and inverted V curves for synchronous motor.

Last Answer : V curves' and inverted V curves' for Synchronous Motor:  V curve:  V curve is a plot of the stator current versus field current for different constant loads. The graph is plotted ... Vcurves of synchronous motor. The highest point on each of these curves indicates unity power factor.

1 answer
128 views

Description : List different torques in synchronous motor. 

Last Answer : Different Torques in Synchronous Motor: 1) Starting torque 2) Running torque 3) Pull-in torque 4) Pull-out torque

1 answer
83 views

Description : Compare characteristics of asynchronous and synchronous transmission mode (four points). 

Last Answer : Synchronous transmission Asynchronous transmission 1. Synchronous transmission are synchronized by an external clock. 1. Asynchronous transmission are synchronized by special signals along the transmission ... for transferring a small amount of data as it is simple and economical.

1 answer
85 views

Description : Compare synchronous and asynchronous counter.

Last Answer : Asynchronous Counter Synchronous Counter In an Asynchronous Counter the output of one Flip Flop acts as the clock Input of the next Flip Flop. In a Synchronous Counter all the Flip Flop's are ... Also called as serial counter Also called as Parallel Counter

1 answer
87 views

Description : Compare Asynchronous sequential and synchronous sequential circuits.

Last Answer : SR. NO. ASYNCHRONOUS SEQUENTIAL CIRCUIT SYNCHRONOUS SEQUENTIAL CIRCUITS. 1 Output can be changed at any instant of time by changing the input Output changes at discrete ... the counter change state simultaneously. This is because all the flip-flops are clocked simultaneously.

1 answer
2.6k views

Description : Synchronous vs asynchronous logic

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

1 answer
92 views

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

1 answer
438 views

Description : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done

Last Answer : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done Raise If1 and lower If2

1 answer
618 views

Description : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as  (1) synchronous motor (2) synchronous generator (3) asynchronous motor (4) asynchronous generator

Last Answer : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as synchronous generator 

1 answer
706 views

Description : The 'Equal area criterion' for the determination of transient stability of a synchronous machine connected to an infinite bus  (1) ignores line as well as synchronous machine resistance ... consideration the possibility of machine losing synchronism after it has survived during the first swing.

Last Answer : 1

2 answers
101 views

Description : Damper winding is provided in 3 phase synchronous motors to :

Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

1 answer
132 views

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

1 answer
201 views

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

1 answer
354 views

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

1 answer
665 views

Description : In a self-controlled synchronous motor fed from a variable frequency inverter  (1) the rotor poles invariably have damper windings  (2) there are stability problems  (3) the speed of the rotor decides stator frequency  (4) the frequency of the stator decides the rotor speed

Last Answer : 2

2 answers
256 views

Description : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s)

Last Answer : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s) only at C

1 answer
116 views

Description : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz

Last Answer : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is 50 Hz

1 answer
100 views

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

1 answer
103 views

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

1 answer
132 views

Description : Torque angle for the synchronous machine is the angle between (A) stator magnetic field and rotor magnetic field (B) stator magnetic field and net magnetic field in the air gap (C) rotor magnetic field and net magnetic field in the air gap (D) excitation voltage and impedance voltage drop

Last Answer : Torque angle for the synchronous machine is the angle between rotor magnetic field and net magnetic field in the air gap

1 answer
100 views

Description : The armature reaction in a synchronous generator supplying leading power factor load is (A) magnetizing (B) demagnetizing (C) demagnetizing and cross-magnetizing (D) magnetizing and cross-magnetizing

Last Answer : The armature reaction in a synchronous generator supplying leading power factor load is magnetizing and cross-magnetizing

1 answer
582 views

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

1 answer
571 views

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Last Answer : Leading

2 answers
92 views

Description : Asynchronous circuits are usually faster than synchronous circuits because

Last Answer : Asynchronous circuits are usually faster than synchronous circuits because they are free running and do not depend on the frequency of the clock

1 answer
113 views

Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

1 answer
229 views

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

1 answer
137 views

Last Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

1 answer
102 views

Last Answer : Slip-rings in a synchronous motor carry direct current.

1 answer
77 views

Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

1 answer
176 views

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

1 answer
203 views

Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

1 answer
101 views

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

1 answer
98 views

Last Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

1 answer
125 views

Last Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

1 answer
118 views

Last Answer : A synchronous motor can develop synchronous torque at synchronous speed.

1 answer
261 views

Last Answer : In case one phase of a three-phase synchronous motor is short-circuited the motor will not start.

1 answer
150 views

Last Answer : In a synchronous motor, the armature current has large values for high and low excitation.

1 answer
200 views

Last Answer :  The size of a synchronous motor decreases with the increase in flux density.

1 answer
154 views

Last Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

1 answer
308 views

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

1 answer
...