Name the material used and the sensitivity of following thermocouple type: (i) J (ii) K (iii) R (iv) S

1 Answer

Answer :

Material used and the sensitivity of following thermocouple:

image

Related questions

Description : Compare Bellows and diaphragm w.r.to construction, sensitivity, working principle and application.

Last Answer : Sr. No Points Bellows diaphragm 1 construction 2 sensitivity Less sensitive as compared to diaphragm  More sensitive as compared to diaphragm ... as well as for vacuum, compound and differential pressure applications. II. For corrosive gases and liquids

Description : Compare orifice plate with venturi tube with reference to: (i) Working principle (ii) Construction (iii) Cost (iv) Pressure loss

Last Answer : Venturi Flow Meter vs Orifice Plate Meter

Description : Give one application each of following transducer: (i) LVDT (ii) RVDT (iii) Capacitive (iv) Piezoelectric

Last Answer : i) LVDT ➢ LVDT used to measure force ➢ LVDT used to measure strain ➢ LVDT used to measure weight ➢ LVDT used to measure tension ➢ LVDT used to measure pressure ➢ The ... flow meters, non-destructive test (NDT) equipment's ➢ Piezoelectric materials are used in ultrasonic transducers.

Description : Related to ultrasonic flow meter: (i) Give any two types of it. (ii) Write any two specifications. (iii) Write two advantages over rotameter. 

Last Answer : (i) Two types of ultrasonic flow meter:  ➢ Transit time flow meters (time differences) ➢ Doppler type. (ii) Write any two specifications: - 1. Accuracy 2. Linearity 3. Repeatability 4. ... for bidirectional flow 8. Excellent dynamic response 9. Good accuracy +-2% 10. o/p is electrical

Description : Draw symbol and characteristic of LDR. Give material used for it.

Last Answer : Symbol of LDR: - ➢ Material used for LDR 1. Light Dependent Resistor (LDR) is made from a piece of exposed semiconductor material such as cadmium sulphide. 2. Materials used ... include, lead sulphide (PbS), lead selenide (PbSe), indium antimonide (InSb) which detect light in the

Description : List any two non-contact type level measurement methods.

Last Answer : • The following are non-contact type level measurement methods 1. Ultrasonic type level measurement 2. Nuclear radiation type level measurement 3. Radar type level measurement 4. Capacitive level transducer. 5. Load cell type level transducer.

Description : State function of strain gauge. Give its types and explain working of any one type of it.

Last Answer : Function of strain gauge: - ➢ The strain gauge is a passive, resistive transducer which converts the mechanical elongation and compression into a resistance change. ➢ This change in ... change in resistivity. 3. Silicon and germanium are used as resistive material for semiconductor gauges

Description : Draw optical type pyrometer and list its advantages. 

Last Answer : Diagram of optical pyrometer ➢ Advantages: - 1) Flexibility 2) Portability 3) Monitor the temperature of moving object 4) Simple assembling of the device enables easy use of it. ... without contacting the heated body. 7) Fast response. 8) High output signal and moderate cost. 

Description : List any two advantages and applications of RADAR type level measurement.

Last Answer : ➢ Advantages: - 1. This is non-contact technology, 2. High accuracy for measurements in storage tanks and some process vessels. 3. Used on difficult hard-to-handle' applications 4. High accuracy 5. ... 6. Powders 7. Bulk solids 8. Ice cream "Premix" mixer 9. Storage tanks for toxic liquids

Description : Compare Nuclear Radiation type and Ultrasonic level measurement.

Last Answer : Sr. No Nuclear Radiation Ultrasonic level  1 Can be installed in highly hazardous areas   Cannot be installed in highly hazardous areas 2 They can measure level in applications ... 7 Measurements can be skewed by density Measurements cannot be skewed by density

Description : Compare U tube manometer and well type manometer

Last Answer : U-tube and well type manometer Sr.No. U-tube manometer well type manometer 1 Both legs are having same cross section area Both legs are having different cross section area ... cross section area. 5 Difference in heights in measured. Single height is measured.

Description : Explain calibration of capacitive type level measurement.

Last Answer : ➢ Calibration of capacitance type level transmitter 1. Remove the level transmitter from the system(tank). 2. check whether transmitter shows zero reading by connecting with multimeter otherwise release the ... rotate the span screw to 20ma. 3. Repeat these steps and check all readings

Description : Draw and explain Doppler type flow measurement.

Last Answer : Doppler type ultrasonic flow meter ➢ Explianation: The Doppler Effect Ultrasonic Flow meter use reflected ultrasonic waves to measure the fluid velocity. There is a change in ultrasonic ... , there will be a frequency shift at the receiver end which is protentional to the velocity

Description : Explain the process of calibration of pressure gauge by Dead Weight Tester.

Last Answer : Deadweight Testers (DWT) are the primary standard for pressure measurement. A dead weight tester is an instrument that calibrates pressure by determining the weight of force divided by the area the force ... at each gauge reading and ensure that it is within the acceptable accuracy limits.

Description : What is piezo electric effect? Name two piezo electric materials.

Last Answer : Piezoelectric Effect: - When pressure or force is applied on piezoelectric crystals such as quartz crystal then an electric charge is generated across that crystal. OR Piezoelectric Effect is the ability ... Topaz 5. Tourmaline 6. lead titanate 7. lead zirconate titanate 8. lithium sulphate

Description : Draw constructional details of C-types Bourdon tube and explain its working

Last Answer : Constructional details of C-types Bourdon tube :   Explanation:- 1. The Bourdon tubes are made out of an elliptically sectioned flat tube bent in such a way as to produce the above ... pressure. 8. The materials used for Bourdon tubes are brass, phosphor bronze, beryllium copper, and steel 

Description : State the selection criteria for transducers

Last Answer : 1. Operating range 2. Operating principle 3. Sensitivity 4. Accuracy 5. Frequency response and resonant frequency 6. Errors 7. Environmental compatibility 8. Usage and ruggedness. 9. ... . 10. Stability and Reliability 11. Loading effect 12. Static characteristics 13. Noise immunity

Description :  State any two advantages of ultrasonic flow meters.

Last Answer : Advantages of ultrasonic level measurement: 1. Offer no obstruction to the flow 2. o/p is insensitive to variation in viscosity, density and temperature 3. No moving parts 4. Linear relationship between ... 8. o/p is electrical 9. It is used as non-contact method of flow measurement.

Description : List any four units of pressure.

Last Answer : • The following are units of Pressure 1. Pascals (Pa or N/m2)—N stands for newton which is SI unit of pressure 2. Psi - Pounds per square inch (PSI) 3. Bar – 105 Pascals 4. mm Hg-millimeters of Mercury 1mm of Hg = 1 Torr 5. Torr – 133.32 Pa 6. cm H2O – 1 cmH2O = 98.068 Pa

Description : Define active and passive transducers. 

Last Answer : 1. Active Transducer: - These transducers do not need any external source of power for their operation. Therefore, they are also called as self-generating type transducers. The active ... need external source of power for their operation. So they are not self-generating type transducers. 

Description : List any two direct methods of level measurement. Explain Hydrostatic method of level measurement. Give one advantage and one disadvantage of it.

Last Answer : ➢ Direct methods of level measurement Direct methods 1. Hook type 2. Sight glass type 3. Float type 4. Dip stick ➢ Hydrostatic method of level measurement. ➢ A liquid in ... - 1. Their calibration gets changed according to variations in product density. 2. Require compressed air.

Description : Draw and explain the construction and working of Dead Weight Tester.

Last Answer : Construction:- Deadweight Tester (DWT) is used for calibration of pressure gauges . A dead weight tester is an instrument that calibrates pressure by determining the weight of force divided by ... the error at each gauge reading and ensure that it is within the acceptable accuracy limits.

Description : Draw neat sketch of Rotameter and explain its working principle.

Last Answer : Rotameter: - A variable-area flowmeter is one where the fluid must pass through a restriction whose area increases with flow rate. The height of the float is directly proportional to the flowrate ... on glass tube and the flow rate can be determined by direct observation of the metering tube  

Description : Explain with neat labelled diagram measurement of flow using venturi meter

Last Answer : Explanation: It is a primary element of differential pressure Flow meters. 1) It consists of a straight inlet section, a converging conical inlet section, a cylindrical throat and diverging recovery ... abruptly, so permanent pressure loss or energy loss is very low as compared to orifice plate.

Description : State Seeback effect and Petlier effect.

Last Answer : See back Effect: - When a pair of dissimilar metals are joined at one end (junction, J1) , and there is a temperature difference between the joined ends and the open ends ( junction , ... effect: Heat is given out or absorbed when an electric current pass across a junction between two materials.

Description : List any two advantages and two applications of Bellows.

Last Answer : Advantages: - 1. It is used to measure absolute & differential pressure. 2. It is used to measure low or medium pressure rang. 3. Bellow joints do not require access; ... . 3. low pressure gauges are suitable for chemical, petrochemical, plant construction, and cleanrooms

Description : Draw and explain filled system thermometer.

Last Answer : ➢ Filled system thermometer Explanation:- Many physical properties change with temperature, such as the volume of a liquid, the length of a metal rod, the electrical resistance of a wire, ... be in absolute units. As the temperature changes ,volume of liquid changes by following equation  

Description : Convert 45°C into Farhenite.

Last Answer : For 45 into ℉

Description : Give classification of level measurement methods.

Last Answer : Classification of Liquid Level Measurement: ➢ Direct method 1. Hook type 2. Sight glass type 3. Float type 4. Dip stick ➢ Indirect method 1. Hydrostatic pressure type 2. Electrical type: a) Capacitance level indicator b) Radiation level detector c) Ultrasonic level gauge 3. Radar type

Description : List any two specifications of electrical pressure transducer.

Last Answer : Specifications of electrical pressure transducer: - 1. Root Sum Squares (RSS) 2. Non-Linearity 3. Hysteresis 4. Non-Repeatability 5. Long-Term Stability 6. Zero Offset 7. Span ... Size 10. associated circuit 11. sensitivity 12. self-generated or external power source 13. Miscellaneous

Description : Give classification of transducer on any two factors

Last Answer : The transducers can be classified as: - 1. Active and passive transducers. 2. Analog and digital transducers. 3. On the basis of transduction principle used. 4. Primary and secondary transducer 5. Transducers and inverse transducers

Description : State necessity of instrument calibration.

Last Answer : Necessity of instrument calibration: - ➢ To ensure reading from an instrument are consistent with other measurements. ➢ To determine the accuracy of the instrument reading. ➢ To ... Calibration Keeps Processes Safe ➢ Calibration Maintains Certification ➢ Reduce Costs from Manufacturing Errors

Description : Match the four material (P, Q, R, S) given in List -I with the corresponding reaction schemes (I, II, III, IV) provided in List-II and select the corr

Last Answer : Match the four material (P, Q, R, S) given in List -I with the corresponding reaction schemes (I, II, III, IV) ... . `{:(P,Q,R,S),(4,1,3,2):}`

Description : Sensitivity calibration against temp. variation shall be carried out. (i) At least once in month* (ii) quarterly. (iii) at least once in six months (iv) Any of above.

Last Answer : i) At least once in month*

Description : A state is known by the system of rights it maintain was said by – (i) Jennings (ii) H. Laski (iii) J.S. Mill (iv) None of the above

Last Answer : (ii) H. Laski

Description : Which of the following are the components of loamy soils? 1. Red soil 2. Clay soil 3. Alluvial soil 4. Silt soil 5. Sandy soil In d i a n So i l , Se a s o n s a n d N a t u r a l Ve g e t a t i o n (a) I and II (b) I, III and IV (c) II and V (d) II, III and V

Last Answer : Ans: (c)

Description : Match List I (Industries) with List II (Important Centers) and select the correct answer using the code given below : L i st I L i st I I (I n dust r i es) (I m por t an t Cent er s) A. Cotton textile I. Ludhiana B. Hosiery II. ... I, C-II, D-III (3) A-III, B-II, C-I, D-IV (4) A-III, B-I, C-II, D-IV

Last Answer : (4) A-III, B-I, C-II, D-IV

Description : Consider the relations R(A,B) and S(B,C) and the following four relational algebra queries over R and S: I. πA,B(R⋈S) II. R⋈πB(S) III. R∩(πA(R) Χ πB(S)) IV. πA,R.B(R Χ S) where R.B refers to ... IV are the same query. (C) I, II and IV are the same query. (D) I, III and III are the same query.

Last Answer : (D) I, III and III are the same query.

Description : Intradermal drug sensitivity tests can detect the presence of following type of hypersensitivity: A. Type I (anaphylactic) B. Type II (cytolytic) C. Type III (retarded) D. All of the above

Last Answer : A. Type I (anaphylactic)

Description : Intradermal drug sensitivity tests can detect the presence of following type of hypersensitivity: A. Type I (anaphylactic) B. Type II (cytolytic) C. Type III (retarded) D. All of the above

Last Answer : A. Type I (anaphylactic)

Description : For the given reaction , `A(g) rarr 2B(g) , Delta_(r)H= 30 kJ//"mole" Delta_(r)S = 150 J//mol` at `300 K` If `C_(P,A) = 20 J//K mol` and `C_(P,B) = 20

Last Answer : For the given reaction , `A(g) rarr 2B(g) , Delta_(r)H= 30 kJ//"mole" Delta_(r)S = 150 J//mol` at ... G` is negative D. At `T = 200, Delta G` is zero

Description : What links the auther j.k rowling, e.nesbit c.s. lewis ,and j.r.r tolkien?

Last Answer : They're all from the U.K. and they all use initials in their pen names.

Description : How many of following metals impart a characteristic colour to the Bunsen flame ? `(i) Na " " (ii) Li " " (iii) K " " (iv) Ba` `(v) Sr " " (vi) Mg " "

Last Answer : How many of following metals impart a characteristic colour to the Bunsen flame ? `(i) Na " " (ii) Li " " (iii) K ... ix) `Be " " (x )Ca " " (x i)Cu`

Description : What does the stomata open? (I) When the guard cells are in flaccid condition (ll) When there is an accumulation of K ions in the guard cells (III) When water enters into the guard cells (IV) When the water potential of ... of adjacent cells (A) II, III and IV I and IV (B) I and III (C) (D) None

Last Answer : (A) II, III and IV

Description : The constitution of India strikes a good balance was said by – (i) I. Jennings (ii) K.C. Wheare (iii) Radhakrishan (iv) Pt. Nehru

Last Answer : (ii) K.C. Wheare

Description : River Alaknanda forms confluences (Prayags) in Uttrakhand. Match the codes given in Figure with Table (Prayags) and select the correct answer using the code given below. Figure Table (Pr ayags) D A L A K N A N D A C B A I. Karn Prayag II. Rudra Prayag III. Nand Prayag IV. Vishnu Prayag

Last Answer : (1) A-II, B-I, C-III, D-IV

Description : Describe following terms w.r.t. Analog voltmeter : (i) Sensitivity (ii) Loading effect

Last Answer : Sensitivity: The sensitivity of a voltmeter is just its capability to detect voltage, usually meaning smaller and smaller voltages. When selecting a meter for a certain voltage measurement, it is ... called loading effect of the voltmeters. It is mainly caused due to low sensitivity instruments.

Description : Who is called the father of Indian Planning? (i) M. Vishneshwariah (ii) Jawaharlal Nehru (iii) Gandhi (iv) B.R.Ambedkar

Last Answer : (i) M. Vishneshwariah

Description : Who was the Vice-President of the Constituent Assembly? (i) Nehru (ii) B.R. Ambedkar (iii) H.C. Mukherjee (iv) None of the above

Last Answer : (iii) H.C. Mukherjee