249 views
The synchronous motor will develop maximum power when the load angle is?

1 Answer

Answer :

The synchronous motor will develop maximum power when the load angle is 900.

Like 0 like

Please log in or register to answer this question.

Related questions

1.5k views

Description : What is the maximum value of torque angle in synchronous motor?

Last Answer : The maximum value of torque angle in synchronous motor is 90 degrees electrical.

1 answer
227 views

Last Answer : The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

1 answer
308 views

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

1 answer
118 views

Last Answer : A synchronous motor can develop synchronous torque at synchronous speed.

1 answer
158 views

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

1 answer
176 views

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

1 answer
106 views

Description : The maximum torque which a synchronous motor will develop at rest for any angular position of the rotor, at rated stator supply voltage and frequency, is known as?

0 answers
100 views

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

1 answer
203 views

Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

1 answer
121 views

Last Answer : If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

1 answer
106 views

Description : In a synchronous motor which losses varies with load?

Last Answer : In a synchronous motor, copper losses varies with load.

1 answer
103 views

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

1 answer
176 views

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

1 answer
507 views

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

1 answer
582 views

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

1 answer
517 views

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

1 answer
133 views

Description : The maximum load that a power transformer can carry is limited by its?

Last Answer : The maximum load that a power transformer can carry is limited by its voltage ratio.

1 answer
354 views

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

1 answer
113 views

Last Answer : (b) Clostridium butylicum Lipase Removal of oil stains

1 answer
341 views

Last Answer : The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

1 answer
381 views

Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

1 answer
79 views

Description : How can we improve power factor using synchronous motor?

0 answers
112 views

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

1 answer
132 views

Description : Torque angle for the synchronous machine is the angle between (A) stator magnetic field and rotor magnetic field (B) stator magnetic field and net magnetic field in the air gap (C) rotor magnetic field and net magnetic field in the air gap (D) excitation voltage and impedance voltage drop

Last Answer : Torque angle for the synchronous machine is the angle between rotor magnetic field and net magnetic field in the air gap

1 answer
101 views

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

1 answer
102 views

Last Answer : Slip-rings in a synchronous motor carry direct current.

1 answer
77 views

Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

1 answer
125 views

Last Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

1 answer
261 views

Last Answer : In case one phase of a three-phase synchronous motor is short-circuited the motor will not start.

1 answer
150 views

Last Answer : In a synchronous motor, the armature current has large values for high and low excitation.

1 answer
200 views

Last Answer :  The size of a synchronous motor decreases with the increase in flux density.

1 answer
154 views

Last Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

1 answer
87 views

Last Answer : The construction of a synchronous motor resembles an alternator.

1 answer
264 views

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

1 answer
111 views

Last Answer : The armature current of the synchronous motor has large values for low and high excitation.

1 answer
97 views

Description : Which motor have more efficiency, synchronous motor or induction motor?

Last Answer : Synchronous motor has more efficiency.

1 answer
108 views

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Last Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

1 answer
310 views

Description : How can we reverse the direction of rotation of synchronous motor?

Last Answer : By reversing supply phase sequence we can reverse the direction of rotation of synchronous motor.

1 answer
101 views

Description : Hunting in synchronous motor cannot be due to?

Last Answer : Hunting in synchronous motor cannot be due to windage friction.

1 answer
162 views

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

1 answer
170 views

Description : An unexcited single phase synchronous motor is ?

Last Answer : An unexcited single-phase synchronous motor is reluctance motor.

1 answer
132 views

Description : A synchronous motor can be made self starting by providing?

Last Answer : A synchronous motor can be made self-starting by providing damper bar.

1 answer
70 views

Description : The back emf of synchronous motor depends on?

Last Answer : The back emf of synchronous motor depends on load angle.

1 answer
95 views

Description : Synchronous motor always runs at which speed?

Last Answer : Synchronous motor always runs at synchronous speed.

1 answer
92 views

Description : Can we use the synchronous motor as the synchronous capacitor?

Last Answer : Yes, we can use the synchronous motor as the synchronous capacitor when the synchrnous motor is overexcited.

1 answer
377 views

Description : what will happen when excitation of an unloaded salient pole synchronous motor suddenly gets disconnected?

Last Answer : When excitation of an unloaded salient pole synchronous motor suddenly gets disconnected the motor will stop.

1 answer
97 views

Description : Three phase synchronous motor will have how many sliprings?

Last Answer : Three phase synchronous motor will have two sliprings.

1 answer
98 views

Last Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

1 answer
112 views

Last Answer : For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

1 answer
129 views

Description : If we change the excitation of synchronous machine will it affect on power factor?

Last Answer : Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

1 answer
...