If we change the excitation of synchronous machine will it affect on power factor?

1 Answer

Answer :

Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

Related questions

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Last Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Last Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

Description : what will happen when excitation of an unloaded salient pole synchronous motor suddenly gets disconnected?

Last Answer : When excitation of an unloaded salient pole synchronous motor suddenly gets disconnected the motor will stop.

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Last Answer : For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Description : How can we improve power factor using synchronous motor?

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Description : Can a synchronous condenser improve power factor?

Last Answer : Yes, synchronous condenser can improve power factor.

Last Answer : A synchronous machine with low value of short-circuit ratio has lower stability limit.

Description : V - curve of synchronous machine shows the relation between?

Last Answer : V - curve of synchronous machine shows the relation between AC armature current and DC field current.

Description : Why synchronous machine is called doubly excited machine?

Last Answer : Armature windings of synchronous machines either deliver 3 phase AC or absorb 3 phase AC source,  whereas field windings are energized from DC source. Thus due to presence of AC on armature and DC on field windings, synchronous machines are often referred as doubly excited machines.

Description : Which machine is the exciter of synchronous machine?

Last Answer : DC shunt machine is the exciter of synchronous machine.

Last Answer : In two part tariff, variation in load factor will affect operating or running charges.

Description : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as

Last Answer : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as long line

Description : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as  (1) synchronous motor (2) synchronous generator (3) asynchronous motor (4) asynchronous generator

Last Answer : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as synchronous generator 

Description : The 'Equal area criterion' for the determination of transient stability of a synchronous machine connected to an infinite bus  (1) ignores line as well as synchronous machine resistance ... consideration the possibility of machine losing synchronism after it has survived during the first swing.

Last Answer : 1

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s)

Last Answer : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s) only at C

Description : Torque angle for the synchronous machine is the angle between (A) stator magnetic field and rotor magnetic field (B) stator magnetic field and net magnetic field in the air gap (C) rotor magnetic field and net magnetic field in the air gap (D) excitation voltage and impedance voltage drop

Last Answer : Torque angle for the synchronous machine is the angle between rotor magnetic field and net magnetic field in the air gap

Description : The synchronous motor will develop maximum power when the load angle is?

Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Description : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then (A) It would over-run the other alternator (B) Its rotor ... (C) Its portion of share in load will increase (D) Its power factor would be decreased.

Last Answer : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then Its portion of share in load will increase

Last Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.

Description : How can we reverse the direction of rotation of synchronous motor?

Last Answer : By reversing supply phase sequence we can reverse the direction of rotation of synchronous motor.

Description : Can we use the synchronous motor as the synchronous capacitor?

Last Answer : Yes, we can use the synchronous motor as the synchronous capacitor when the synchrnous motor is overexcited.

Description : Why do we need to correct power factor?

Last Answer : Slip-rings in a synchronous motor carry direct current.

Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Last Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

Last Answer : A synchronous motor can develop synchronous torque at synchronous speed.