Can a synchronous condenser improve power factor?

1 Answer

Answer :

Yes, synchronous condenser can improve power factor.

Related questions

Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Description : Why capacitors are used to improve power factor?

Last Answer :  Capacitors generate reactive power instead of that drawn from source which is required by inductive loads.so it reduce the reactive current which is drawn from source to be drawn from capacitor.This control in Electric bills cost.

Description : How does a capacitor improve power factor?

Last Answer : Every circuit are usually more inductive than capacitive.it means that the current lags by voltage at small angle.hence we have to compensate this situation so we use Capacitor then this lag is compensate ... angle becomes low and the value of cos(phase angle) is increase and hence power also max.

Description : where the synchronous condenser are generally installed ?

Last Answer : the synchronous condenser are generally installed at receiving end side of transmission line 

Description : What is Synchronous condenser?

Last Answer : Synchronous condenser Big advantage of synchronous condenser is their large temporary overload capability and good harmonics performance. Synchronous condenser is ... ;voltage levels. Synchronous condenser have slow speed of response.

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Last Answer : For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

Description : If we change the excitation of synchronous machine will it affect on power factor?

Last Answer : Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : State the function of cooling tower and condenser in thermal power station.

Last Answer : 1. Condenser:   Function of condenser is to convert exhaust steam again into water by reducing its temperature with the help of cold water. Also it reduces back pressure of steam turbine 2 ... tower : The function of cooling tower is to reduce the temperature of water coming from condenser.

Last Answer : An induction motor has relatively high power factor at near full load.

Last Answer : For a consumer the most economical power factor is generally 0.95 lagging .

Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Last Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Last Answer : Load factor of a power station is generally less than unity.

Last Answer : Load factor of a power station is defined as average load/maximum demand.

Description : What is the maximum value of power factor?

Last Answer : 1 is the maximum value of power factor.

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Last Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

Description : The synchronous motor will develop maximum power when the load angle is?

Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

Description : operating principle of condenser type microphone with neat diagram.

Last Answer : Principle: When sound pressure moves the diapharam in, the capacitance increases, and when it moves out, the capacitance decreases. The change in capacitance results in change in out put voltage of microphone. ... in volts.  Q= charge in coulombs  C= capacitance in farad Diagram: 

Description : Explain working of superheater and condenser. 

Last Answer : Working of Super heater:  Super heater consist of group of tubes. Tubes are heated by absorbing temperature of flue gases passed over it . Superheated steam' is meant that steam which ... condensate is reused in boiler. This type of condenser is used for high capacity thermal power plant. 

Description : What is meant by Power factor?

Last Answer : Ans. Power factor means ratio of true power to apparent power. It is cosine of phase angle between voltage and current. Its value is 1 for Unity P.F. Loads, 0 to 1 lagging for inductive loads and o to 1 leading for capacitive loads.

Description : State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Last Answer : i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

Description : Briefly explain how the power factor of an inductive circuit can be improved.

Last Answer : As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

Description : Discuss how power factor tariff results into energy conservation.

Last Answer : Power factor tariff results into energy conservation: i) Applying incentives and penalties according to power factor is an effective way, which enables consumer to improve power factor so that he can ... finally leads to reduction in the current drawn by the load and helps for energy conservation.

Description : Draw and explain bulk correction method for power factor & control.

Last Answer : Bulk correction method for power factor & control: i) Here individual starter controls the capacitors located at distribution panel. ii) Centralized compensation is employed in large industrial plants where many ... capacitor units in steps to maintain P.F. more than preset limit (0.95). 

Description : State the incentives and penalties related with power factor tariff.

Last Answer : Incentives and penalties related with power factor tariff: In addition to basic tariff (Maximum Demand Tariff / KVA Maximum Demand Tariff / Load factor tariff) the tariff in which P.F. of ... industrial consumer/H.T/ commercial consumers with contract demand above 80 kw/ 100Kva/107 hp consumer.

Description : With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Last Answer : Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load. 

Description : State the significance of power factor.

Last Answer : Significance of power factor:-  1. Cosine of angle between voltage & current in a circuit is called power factor. 2. It is a measure of the real power in a circuit. 3. Inductive & ... KVA rating equipment 5. Greater conductor size 6. CosØ = R/Z  CosØ= Active Power/ Apparent Power 

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : The power factor of dielectric :  (A) is a function of temperature of the dielectric only (B) depends only on voltage stress to which the dielectric is stressed (C) always constant (D) both (A) and (B)

Last Answer : The power factor of dielectric :  (A) is a function of temperature of the dielectric only (B) depends only on voltage stress to which the dielectric is stressed (C) always constant (D) both (A) and (B)

Description : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : The benefit of power factor correction in a power system is (A) lower power consumption (B) increased demand charge (C) reduced load carrying capabilities in existing lines (D) reduced voltage profile

Last Answer : The benefit of power factor correction in a power system is lower power consumption

Description : The power factor of a D.C. circuit is always?

Last Answer : The power factor of a D.C. circuit is always unity.

Description : The ratio of active power to apparent power is known as____ factor.

Last Answer : The ratio of active power to apparent power is known as power factor.

Description : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is?

Last Answer : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is 32 kW.

Description : Power factor of electric bulb is?

Last Answer : Power factor of electric bulb is unity.

Description : The power factor at resonance in R-L- C parallel circuit is?

Last Answer : since a rlc circuit at resonance behaves like a pure resistive circuit, i.e there is no phase difference between current and voltage, hence the power factor is unity.

Description : Power factor of the system is kept high?

Last Answer : Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

Description : Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Last Answer : Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

Description : Capacitors for power factor correction are rated in?

Last Answer : Capacitors for power factor correction are rated in kVAR.