Please Log in or Register for more.

A ferro resonant transformer regulation is also known as?


95 views

1 Answer

Answer :

A ferro resonant transformer regulation is also known as constant current transformer.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : A transformer can have regulation closer to zero on leading power factor.

Show More

140 views 1 answer







A good voltage regulation of a transformer means?
Last Answer : A good voltage regulation of a transformer means output voltage fluctuation from no load to full load is least.

Show More

98 views 1 answer







A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging
Last Answer : 0

Show More

5.1k views 3 answers







Describe the concept of Ferro electricity. Explain the application of Ferro electric material
Last Answer : The ferroelectric material has an electric dipole moment and it is spontaneously polarized. They have high dielectric constant which is nonlinear because it is dependent on the intensity of ... used in condensers to concentrate considerable quantities of electric energy within a small space. 

Show More

81 views 1 answer







Negative voltage regulation is indicative that the load is?
Last Answer : Negative voltage regulation is indicative that the load is capacitive.

Show More

236 views 1 answer







Minimum voltage regulation occurs when the power factor of the load is?
Last Answer : Minimum voltage regulation occurs when the power factor of the load is leading.

Show More

224 views 1 answer







A series R-L-C Circuit has a resonant frequency of 1000 Hz. If the values of R, L and C are doubled, the new resonant frequency is
Last Answer : A series R-L-C Circuit has a resonant frequency of 1000 Hz. If the values of R, L and C are doubled, the new resonant frequency is 500 Hz

Show More

453 views 1 answer







In a series L-C circuit at the resonant frequency the?
Last Answer : In a series L-C circuit at the resonant frequency the current is maximum.

Show More

181 views 1 answer







In R-L-C series resonant circuit magnitude of resonance frequency can be changed by changing the value of?
Last Answer : In R-L-C series resonant circuit magnitude of resonance frequency can be changed by changing the value of L or C.

Show More

1.2k views 1 answer







In series resonant circuit, increasing inductance to its twice value and reducing capacitance to its half value?  
Last Answer : In series resonant circuit, increasing inductance to its twice value and reducing capacitance to its half value will increase the selectivity of the circuit.

Show More

747 views 1 answer







In a series resonant circuit, the impedance of the circuit is?
Last Answer : In a series resonant circuit, the impedance of the circuit is minimum.

Show More

791 views 1 answer







Define line regulation and load regulation.
Last Answer : Load regulation is the ability of the power supply to maintain its specified output voltage over changes in the load. Line regulation is the ability of the power supply to maintain its specified output voltage over changes in the input line voltage.

Show More

329 views 3 answers







Classify hydro-electric power plants according to water flow regulation and explain in brief.
Last Answer : Classification of hydro-electric power plants according to water flow regulation of water flow:-  1. Large reservoir power plant 2. Run-off river (ROR) power plant with poundage 3. Run-off River ... depends upon rate of flow of water Initial cost is less Its purpose is to generate electricity.

Show More

84 views 1 answer







Define load and line regulation.
Last Answer : 1. Load regulation : The load regulation indicates how much the load voltage changes when the load current changes. The load regulation is defined as:  % Load regulation = (VNL-VFL) / VFL *100  ... the power supply. A well-regulated power supply can have a line regulation of less than 0.1%.  

Show More

101 views 1 answer







Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound
Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Show More

124 views 1 answer







The unit of speed regulation of a governor is :  (A) Hz (B) Hz/MW (C) Hz/MVA (D) rpm/MVAR
Last Answer : The unit of speed regulation of a governor is : Hz/MW

Show More

226 views 1 answer








Last Answer : The voltage regulation in magnetic amplifier type voltage regulator is effected by varying the reactance.

Show More

106 views 1 answer







Which motor has the best speed regulation?

Show More

57 views 0 answers







State and justify which of the following two transformers is better:  Transformer A = 4% voltage regulation  Transformer B = 6% voltage regulation
Last Answer : Transformer A with 4% voltage regulation is better.  Justification: Voltage regulation refers to the percentage change in secondary voltage when load is changed from no-load to full-load with primary voltage ... 4% voltage regulation, which is less as compared to 6% of transformer B, it is better.

Show More

181 views 1 answer







Explain the effect of Harmonics on the Transformer.
Last Answer : Effect of Harmonics on the Transformer:  1. Core loss: Harmonic voltage increases the hysteresis and eddy current losses in the lamination. The amount of the core loss depends on ... small core vibrations.  5. Saturation problem: Sometimes additional harmonic voltage causes core saturation.

Show More

130 views 1 answer







List two special feature of welding transformer.
Last Answer : Special features of welding transformer: i) It is a step down transformer that reduces the source voltage to a voltage desired according to the demands of the welding process. ii) Having large primary turns and less ... V ii) Secondary voltage - 40 to 60 V iii) Secondary current - 200 to 600 A

Show More

154 views 1 answer







State two applications of isolation transformer
Last Answer : Applications of isolation transformer: i) Isolates the load equipment from supply ground: ii) Reduction of voltage spikes iii) It acts as a decoupling device. iv) Protects loads from harmonic distortion.

Show More

54 views 1 answer







State why a transformer always have an efficiency of more than 90%.
Last Answer : As transformer is static device with no moving parts, the losses due to friction & windage are completely absent. Hence transformer has efficiency of more than 90%.

Show More

279 views 1 answer







Equivalent circuit of transformer
Last Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

Show More

381 views 2 answers







Single phase transformer
Last Answer : Single phase Transformer Transformer

Show More

261 views 1 answer







What is the use of transformer?
Last Answer : The use of transformer  is to do lower or raise  the voltage or currents in an electrical  circuit.  That's quite so simple. 

Show More

160 views 1 answer







Write about transformer on DC.
Last Answer : Transformer on DC : Transformer cannot work on DC. Transformer works on electromagnetic induction principle. Electromagnetic induction principle means when flux linking with coil changes and EMF induced in it ... winding insulation will burn. https://youtu.be/TVp_0fIfxqY

Show More

248 views 1 answer













State any four characteristics of core type transformer.
Last Answer : Characteristics of core type transformer: i) It has one window. ii) It has one magnetic circuit. iii) Core surrounds the winding. iv) Average length of core is more. v) Area of cross ... Better cooling for winding. vii) Mechnical strength is comparatively less. viii) Repair and maintenance is easy.

Show More

132 views 1 answer







Explain construction and working of single phase Auto transformer.
Last Answer : Construction of single phase auto transformer: (i) It has only one winding wound on a laminated circular magnetic core. (ii) The core is made of silicon steel stampings. (iii) The two terminals of the ... help of handle. 5) The same transformer can be used as step-up or step down auto-transformer

Show More

347 views 1 answer








Last Answer : No-load current in a transformer lags behind the voltage by about 75°.

Show More

90 views 1 answer








Last Answer : The purpose of providing an iron core in a transformer is to decrease the reluctance of the magnetic path.

Show More

205 views 1 answer








Last Answer : In the transformer low voltage winding has got more cross-sectional area.

Show More

256 views 1 answer








Last Answer : A transformer cannot raise or lower the voltage of a D.C. supply because Faraday's laws of electromagnetic induction are not valid since the rate of change of flux is zero.

Show More

351 views 1 answer








Last Answer : Primary winding of a transformer could either be a low voltage or high voltage winding.

Show More

86 views 1 answer








Last Answer : High voltage winding in a transformer has more number of turns.

Show More

363 views 1 answer








Last Answer : The efficiency of a power transformer is of the order of 98 percent.

Show More

100 views 1 answer








Last Answer : The no load current in a transformer lags behind the applied voltage by an angle of about 75°.

Show More

188 views 1 answer








Last Answer : In a transformer, routine efficiency depends upon load current and power factor of load.

Show More

133 views 1 answer








Last Answer : The maximum efficiency of a distribution transformer is at 50% full load.

Show More

141 views 1 answer








Last Answer : Transformer breaths in when load on it decreases.

Show More

90 views 1 answer








Last Answer : No-load current of a transformer has small magnitude and low power factor.

Show More

72 views 1 answer








Last Answer : The purpose of providing iron core in a step-up transformer is to decrease the magnitude of magnetizing current.

Show More

546 views 1 answer








Last Answer : The power transformer is a constant main flux device.

Show More

63 views 1 answer








Last Answer : In a transformer, the tappings are generally provided on low voltage side.

Show More

92 views 1 answer








Last Answer : The use of higher flux density in the transformer design reduces weight per kVA.

Show More

126 views 1 answer








Last Answer : The chemical used in breather for transformer should have the quality of cleansing the transformer oil.

Show More

187 views 1 answer








Last Answer : An ideal transformer has infinite values of primary and secondary inductances. The statement is false.

Show More

327 views 1 answer








Last Answer : The transformer ratings are usually expressed in terms of kVA.

Show More

318 views 1 answer








Last Answer : Material used for construction of transformer core is usually silicon steel.

Show More

241 views 1 answer






Show More⇦ PreviousNext ⇨