D.C. shunt relays are made of many turns of thin wire.

Related questions

Description : List the main parts of D.C. motor

Last Answer : Main parts of D.C. motor and their functions:  Part Functions Yoke i) Provides mechanical support for poles. ii) Acts as protecting cover for machine. iii) Carries magnetic flux. ... a fixed physical position relative to the stator.  Shaft Used to transfer mechanical power 

Description : Write two applications of D.C. series motor. 

Last Answer : The applications of D.C. series motor: 1. Cranes 2. Hoists 3. Trolley and cars 4. Conveyors 5. For traction work i.e. electric locomotives 6. Elevator 7. Air compressor

Description : State the principle of operation of d.c. motor.

Last Answer : When a current carrying conductor is placed in a magnetic field, the conductor experiences the force. The magnitude of force is given by F = BIL newton  where F – Force   B – maximum flux density   I – Current   L – Length of conductor

Description : Briefly define each of the following: (a) 1 coulomb (b) 1 volt (c) 1 ampere (d) 1 ohm.

Description : IDMT relays are used to protect the transformer against :  (A) Internal short -circuits (B) Open circuits (C) External short circuits (D) Oil leakage

Last Answer : IDMT relays are used to protect the transformer against : External short circuits

Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Last Answer : The single phasing relays are used for the protection of three phase motors.

Last Answer : Impedance relays are used for phase faults on long line.

Last Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Last Answer : To protect most of the electrical equipment handling low power, the types of relays used are thermocouple, electronic and bimetallic.

Last Answer : Protective relays are devices that detect abnormal conditions in electrical circuits by measuring constantly the electrical quantities which differ during normal and abnormal conditions.

Last Answer : Directional relays are based on flow of power.

Last Answer : Thermal overload relays are used to protect the motor against overcurrent due to heavy loads.

Last Answer : Overload relays are of induction, solid state, thermal, electromagnetic type.

Last Answer : Relays can be designed to respond to changes in resistance, reactance or impedance voltage and current, light intensity, temperature.

Last Answer : Shunt capacitance is neglected while considering short transmission line.

Description : How many types of types of relays are there?

Description : Consider the following statements. Which of these statements are correct ?  (1) Reactance relays are preferred for ground fault relaying  (2) Impedance relays are most suitable for:protecting long transmission lines  (3) Mho relays are best ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)

Last Answer : Consider the following statements. Which of these statements are correct ?  (1) Reactance relays are preferred for ground fault relaying  (2) Impedance relays are most suitable for:protecting long transmission lines  (3) Mho relays are ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)

Description : A 4-pole, dc shunt motor working on 250V takes a current of 2A when running at no load on 1000 rpm. Calculate its back emf and speed at load if the motor takes 51A. Armature and shunt field resistance are 0.2Ω and 250Ω respectively

Description : Describe the operation of shunt capacitor filter with the help of circuit diagram and waveforms.

Description : Describe the operation of shunt capacitor filter with the help of circuit diagram and waveforms.

Description : DC shunt motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Last Answer : increases

Description : State any four applications of DC shunt motor.

Last Answer : Applications of DC shunt motor: 1) Lathe machines 2) drilling machines 3) milling machines 4) Printing machinery 5) Paper industry 6) centrifugal and reciprocating pumps 7) blowers 8)fans

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : State the use of shunt and series resistance used in extension of meter.

Last Answer : Use of shunt and series resistance: i) Use of shunt: To extend the range of Ammeter. ii) Use of series resistance: To extend the range of Voltmeter.

Description : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Last Answer : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : Shunt compensation in an EHV line is used to (A) Improve stability. (B) Improve the voltage profile. (C) Reduce the fault level. (D) Substitute for synchronous phase modifier.

Last Answer : Shunt compensation in an EHV line is used to Improve the voltage profile.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A shunt fault is characterized by (A) Increase in current, frequency and pf (B) Increase in current, reduction in frequency and pf (C) Increase in current and frequency, reduction in pf (D) Decrease in current and frequency

Last Answer : B

Last Answer : The function of shunt in an ammeter is to by pass the current.

Description : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave?

Last Answer : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

Last Answer : A cumulatively compounded long shunt generator when operating as a motor would be differentially compounded long shunt.

Description : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Description : In a shunt generator the voltage build up is generally restricted by?

Description : A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly?

Last Answer : 200V/E2 = 1000/1200 E2= 240 V

Last Answer : If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens this will make armature to take heavy current, possibly burning it.

Last Answer : The purpose of retardation test on D.C. shunt machines is to find out stray losses.