308 views

1 Answer

Answer :

Ionization in circuit breaker is facilitated by high temperature, increase of mean free path, increasing field strength.

Like 0 like

Please log in or register to answer this question.

Related questions

120 views

Description : The arc temperature in Oil Circuit Breaker may reach up to_______.  (A) 5,000° K (B) 8,000° K (C) 10,000° K (D) None of the above

Last Answer : The arc temperature in Oil Circuit Breaker may reach up to 5,000° K 

1 answer
659 views

Description : The number of cycles in which a high speed circuit breaker can complete its operation is  (A) 3 to 8 (B) 10 to 18 (C) 20 to 30 (D) 40 to 50

Last Answer : The number of cycles in which a high speed circuit breaker can complete its operation is 3 to 8

1 answer
106 views

Description : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Last Answer : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

1 answer
167 views

Description : The Minimum Oil Circuit Breaker (MOCB) is named because of :  (A) Reduced requirement of oil (B) Reduced requirement of air (C) All of the above (D) None of the above

Last Answer : The Minimum Oil Circuit Breaker (MOCB) is named because of : Reduced requirement of oil 

1 answer
80 views

Description : For selecting a circuit breaker, ______ should be determined.  (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Last Answer : For selecting a circuit breaker, ______ should be determined. (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

1 answer
85 views

Description : ln a minimum oil circuit breaker the oil is used

Last Answer : ln a minimum oil circuit breaker the oil is used to act as circuit breaking medium only

1 answer
88 views

Last Answer : Arc in a circuit breaker is interrupted at zero current.

1 answer
326 views

Last Answer : The arc voltage produced in A.C. circuit breaker is always in phase with the arc current.

1 answer
122 views

Last Answer : In a circuit breaker the basic problem is to transmit large power.

1 answer
431 views

Last Answer : The voltage appearing across the contacts after opening of the circuit breaker is called recovery voltage.

1 answer
79 views

Last Answer : Air blast circuit breaker is used for repeated duty.

1 answer
221 views

Last Answer : Magnetic circuit breaker has instantaneous trip action.

1 answer
156 views

Last Answer : Thermal circuit breaker has delayed trip action.

1 answer
119 views

Last Answer : The arcing contacts in a circuit breaker are made of copper tungsten alloy.

1 answer
99 views

Description : what is SF6 circuit breaker?

Last Answer : SF6 is Sulpher hexa Fluoride gas. If this gas is used as arc quenching medium in a Circuit breaker means SF6 CB.

2 answers
29 views

Description : Explain about Circuit Breaker

Last Answer : Ans: CIRCUIT BREAKERS: In the case of outdoor type installation, the circuit breakers have fixed location and the station layout is such that adequate section clearances are always available from ... carried out as above, every circuit breaker will be completely overhauled after five year interval.

1 answer
11 views

Description : How to Reset a Circuit Breaker

Last Answer : How to Reset a Circuit Breaker All is well with the lights and your electrical appliances one minute, then everything falls into pitch-black darkness the next moment. When a room in your house ... electrical fires. With these tips, a power surge does not have to be a permanent inconvenience.

1 answer
15 views

Description : How to Install a Circuit Breaker

Last Answer : How to Install a Circuit Breaker A circuit breaker is an essential component of a home's electric system. When power surges occur, it trips then shuts off the electricity, preventing ... -functional electrical system. Just make sure you take proper safety precautions when installing this device.

1 answer
216 views

Description : Explain working of static AC circuit breaker. 

Last Answer : Static AC Circuit breaker: The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

1 answer
949 views

Description : Explain working of AC circuit breaker using SCR with circuit diagram.

Last Answer : AC Circuit Breaker:  The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... to non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

1 answer
469 views

Description : State function of starter and ELCB. (Earth Leakage Circuit Breaker)

Last Answer : i) Function of Starter:- 1. To prevent the high starting current OR to minimize the starting current. 2. To give supply failure protection 3. To give over load and short circuit protection ... an installation and cut off the circuit from power supply and avoid electrical shock to the person.

1 answer
279 views

Description : Breaking capacity of a circuit breaker is usually expressed in terms of  (1) Ampere (2) Volts (3) MW (4) MVA

Last Answer : Breaking capacity of a circuit breaker is usually expressed in terms of MVA

1 answer
143 views

Description : The arc voltage in a circuit breaker is :

Last Answer : The arc voltage in a circuit breaker is : in phase with the arc current

1 answer
121 views

Description : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

Last Answer : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

1 answer
37 views

Description : Ionization in circuit breaker is facilitated by (a) high temperature (b) increase of mean free path (c) increasing field strength (d) all of the above

Last Answer : (d) all of the above

1 answer
3.0k views

Description : If the % reactance upto the fault point is 20%, then the short circuit current will be

Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

1 answer
306 views

Description : Which of the following circuit breakers has high reliability & minimum maintenance?  (A) Bulk oil type CB (B) Air blast CB (C) Vacuum CB (D) Sulphur hexafluoride CB 

Last Answer : Which of the following circuit breakers has high reliability & minimum maintenance?  (A) Bulk oil type CB (B) Air blast CB (C) Vacuum CB (D) Sulphur hexafluoride CB 

1 answer
112 views

Description : The following is/are the characteristics of SF6 circuit breakers:  (A) It does not need an auxiliary breaking chamber (B) Short break time of 2 to 2.5 cycles (C) All of the above (D) None of the above

Last Answer : The following is/are the characteristics of SF6 circuit breakers:  (A) It does not need an auxiliary breaking chamber (B) Short break time of 2 to 2.5 cycles (C) All of the above (D) None of the above

1 answer
165 views

Last Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

1 answer
210 views

Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

1 answer
176 views

Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

1 answer
127 views

Last Answer : The time of closing the cycle, in modern circuit breakers is 0.003 sec.

1 answer
443 views

Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by?

Last Answer : The current zero interruption, in oil and air blast circuit breakers, is achieved by lengthening of the gap, cooling and blast effect.

1 answer
331 views

Last Answer : Circuit breakers are essentially current carrying contacts called electrodes.

1 answer
109 views

Last Answer : Circuit breakers usually operate under transient state of short-circuit current.

1 answer
285 views

Description : Arc in a circuit behaves as?

Last Answer : Arc in a circuit behaves as a resistance decreasing with voltage rise across the arc.

1 answer
137 views

Description : In which fault the maximum short circuit current occurs?

Last Answer : In three phase bolted fault the maximum short circuit occurs.

1 answer
60 views

Description : Can An Rc Circuit Be Used As Clock Source For 8085?

Last Answer : Answer :Yes, it can be used, if an accurate clock frequency is not required. Also, the component cost is low compared to LC or Crystal.

1 answer
64 views

Description : What is the purpose of Overload Protection in a motor circuit?

Last Answer : Ans. The Overload Protection is used in a motor circuit to protect it from sustained over currents.

1 answer
9 views

Description : microproject on synchronised UJT triggring circuit

0 answers
6 views

Description : How to Do Circuit Training

Last Answer : How to Do Circuit Training Circuit exercise is a set of exercises designed to burn as much calories as possible while integrating and engaging different kinds of movements all over your body. After finishing ... up your stamina to be able to finish five circuits in a session, so pace yourself.

1 answer
19 views

Description : Refer to the circuit below. The total absorbed (consumed) power is:

0 answers
567 views

Description : Draw the circuit diagram of battery charger using SCR and explain it’s working.

Last Answer : Battery charger circuit using SCR: The figure shows the battery charger circuit using SCR. A 12V discharged battery is connected in the circuit and switch SW is closed. The singlephase 230V ... not fired. In this way, after full charging, further charging is automatically stopped.

1 answer
597 views

Description : With neat diagram explain synchronized UJT triggering circuit.

Last Answer : Line Synchronized UJT triggering circuit: The UJT is almost ideal as a firing device for SCRs. There are 2 main reasons for the compatibility between UJTs and SCRs. Firstly, the UJT produces a ... , the SCR is sure to have the right polarity between the anode and cathode for turning on.

1 answer
99 views

Description : Draw circuit diagram of symmetrical configuration of bridge converter.

Last Answer : circuit diagram of symmetrical configuration of bridge converter

1 answer
135 views

Description : Draw circuit diagram of Class B commutation.

Last Answer : Class B: Resonant Pulse Commutation:

1 answer
406 views

Description : Equivalent circuit of transformer

Last Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

2 answers
195 views

Description : Briefly explain how the power factor of an inductive circuit can be improved.

Last Answer : As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

1 answer
277 views

Description : Draw equivalent circuit of alternator.

Last Answer : Equivalent circuit of alternator

1 answer
124 views

Description : Why does leakage occur in a magnetic circuit?

0 answers
...