1 Answer

Answer :

In a circuit breaker the basic problem is to transmit large power.

Related questions

Description : The arc temperature in Oil Circuit Breaker may reach up to_______.  (A) 5,000° K (B) 8,000° K (C) 10,000° K (D) None of the above

Last Answer : The arc temperature in Oil Circuit Breaker may reach up to 5,000° K 

Description : The number of cycles in which a high speed circuit breaker can complete its operation is  (A) 3 to 8 (B) 10 to 18 (C) 20 to 30 (D) 40 to 50

Last Answer : The number of cycles in which a high speed circuit breaker can complete its operation is 3 to 8

Description : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Last Answer : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Description : The Minimum Oil Circuit Breaker (MOCB) is named because of :  (A) Reduced requirement of oil (B) Reduced requirement of air (C) All of the above (D) None of the above

Last Answer : The Minimum Oil Circuit Breaker (MOCB) is named because of : Reduced requirement of oil 

Description : For selecting a circuit breaker, ______ should be determined.  (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Last Answer : For selecting a circuit breaker, ______ should be determined. (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Description : ln a minimum oil circuit breaker the oil is used

Last Answer : ln a minimum oil circuit breaker the oil is used to act as circuit breaking medium only

Last Answer : Arc in a circuit breaker is interrupted at zero current.

Last Answer : The arc voltage produced in A.C. circuit breaker is always in phase with the arc current.

Last Answer : Ionization in circuit breaker is facilitated by high temperature, increase of mean free path, increasing field strength.

Last Answer : The voltage appearing across the contacts after opening of the circuit breaker is called recovery voltage.

Last Answer : Air blast circuit breaker is used for repeated duty.

Last Answer : Magnetic circuit breaker has instantaneous trip action.

Last Answer : Thermal circuit breaker has delayed trip action.

Last Answer : The arcing contacts in a circuit breaker are made of copper tungsten alloy.

Description : what is SF6 circuit breaker?

Last Answer : SF6 is Sulpher hexa Fluoride gas. If this gas is used as arc quenching medium in a Circuit breaker means SF6 CB.

Description : Explain about Circuit Breaker

Last Answer : Ans: CIRCUIT BREAKERS: In the case of outdoor type installation, the circuit breakers have fixed location and the station layout is such that adequate section clearances are always available from ... carried out as above, every circuit breaker will be completely overhauled after five year interval.

Description : How to Reset a Circuit Breaker

Last Answer : How to Reset a Circuit Breaker All is well with the lights and your electrical appliances one minute, then everything falls into pitch-black darkness the next moment. When a room in your house ... electrical fires. With these tips, a power surge does not have to be a permanent inconvenience.

Description : How to Install a Circuit Breaker

Last Answer : How to Install a Circuit Breaker A circuit breaker is an essential component of a home's electric system. When power surges occur, it trips then shuts off the electricity, preventing ... -functional electrical system. Just make sure you take proper safety precautions when installing this device.

Description : Explain working of static AC circuit breaker. 

Last Answer : Static AC Circuit breaker: The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : Explain working of AC circuit breaker using SCR with circuit diagram.

Last Answer : AC Circuit Breaker:  The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... to non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : State function of starter and ELCB. (Earth Leakage Circuit Breaker)

Last Answer : i) Function of Starter:- 1. To prevent the high starting current OR to minimize the starting current. 2. To give supply failure protection 3. To give over load and short circuit protection ... an installation and cut off the circuit from power supply and avoid electrical shock to the person.

Description : Breaking capacity of a circuit breaker is usually expressed in terms of  (1) Ampere (2) Volts (3) MW (4) MVA

Last Answer : Breaking capacity of a circuit breaker is usually expressed in terms of MVA

Description : The arc voltage in a circuit breaker is :

Last Answer : The arc voltage in a circuit breaker is : in phase with the arc current

Description : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

Last Answer : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

Description : Basic Circuit Elements Symbols

Last Answer : Basic Circuit Elements Symbols

Description : Basic Circuit Elements

Last Answer : Resistance ,current,voltage

Description : basic gate drive circuit of GTO

Last Answer : basic gate drive circuit of GTO

Description : How To Make Basic Liquid Gel Soap

Last Answer : 2 cups soap flakes or grated bar soap 1/2 gallon water 2 tbsp glycerin Mix ingredients together in a large pot or dutch oven. Set over low heat, stirring occasionally until the soap has dissolved. Transfer to a jar and cover tightly. For a less thick gel soap, use 1 gallon of water.

Description : Basic idea of generation 

Last Answer : Prior to the discovery of Faraday's Laws of electromagnetic discussion, electrical power was available from batteries with limited voltage and current levels. Although complicated in construction, D ... Therefore, area specific generating stations along with its distribution networks had to be used.

Description : What are the basic requirements of locating wind power plant ?

Last Answer : The basic requirements of locating wind power plant:  1) The site should be selected where winds are strong i.e. where pressure of wind is high and there is continuity. 2) Wind pressure ... the turbine which can affect the system's overall performance. 10)Possibility to connect to power grid. 

Description : Basic SI units

Last Answer : Basic SI units

Description : 1.Determine the permeability of magnetic material by plotting its BH curve 2. Measure voltage, current and power in 1-phase circuit with resistive load. 3. Measure voltage, current and ... .Make Star and Delta connection in induction motor starters and measure the line and phase values.

Last Answer : Practical no. 6 Aim: Make Star and Delta connection in induction motor starters and measure the line and phase values. Apparatus required:  voltmeter, ammeter, induction motor Circuit diagram ... Result: Hence we have measured the line and phase value of star and delta connection.

Description : Describe the basic SHA operation with the help of its four mode specifications.

Last Answer : Sample-and-hold amplifier (SHA) is a unity gain amplifier with a mode control switch where the input of the amplifier is connected to a time-varying signal. A trigger pulse at the mode control switch ... but other forms, such as optical and mechanical forms, are possible. Also denoted S/H.

Description : A 3 phase 50 Hz induction motor has full load speed of 970 rpm. Calculate no of poles and slip frequency.

Last Answer : The number of poles in an induction motor can be calculated using the following formula: No. of poles = (120 * frequency) / speed In this case, the number of poles would be calculated as follows: No. of poles = ( ... ) - 50 Hz = 8.08 Hz So the motor has 6 poles and a slip frequency of 8.08 Hz.

Description : If the % reactance upto the fault point is 20%, then the short circuit current will be

Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Description : Which of the following circuit breakers has high reliability & minimum maintenance?  (A) Bulk oil type CB (B) Air blast CB (C) Vacuum CB (D) Sulphur hexafluoride CB 

Last Answer : Which of the following circuit breakers has high reliability & minimum maintenance?  (A) Bulk oil type CB (B) Air blast CB (C) Vacuum CB (D) Sulphur hexafluoride CB 

Description : The following is/are the characteristics of SF6 circuit breakers:  (A) It does not need an auxiliary breaking chamber (B) Short break time of 2 to 2.5 cycles (C) All of the above (D) None of the above

Last Answer : The following is/are the characteristics of SF6 circuit breakers:  (A) It does not need an auxiliary breaking chamber (B) Short break time of 2 to 2.5 cycles (C) All of the above (D) None of the above

Last Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Last Answer : The time of closing the cycle, in modern circuit breakers is 0.003 sec.

Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by?

Last Answer : The current zero interruption, in oil and air blast circuit breakers, is achieved by lengthening of the gap, cooling and blast effect.

Last Answer : Circuit breakers are essentially current carrying contacts called electrodes.

Last Answer : Circuit breakers usually operate under transient state of short-circuit current.

Description : Arc in a circuit behaves as?

Last Answer : Arc in a circuit behaves as a resistance decreasing with voltage rise across the arc.

Description : In which fault the maximum short circuit current occurs?

Last Answer : In three phase bolted fault the maximum short circuit occurs.

Description : What do you do when you have a problem that you can't solve until the next morning?

Last Answer : Sleep on it. Go do some exercise, burn yourself out and get rid of the nervous energy.

Description : Sinusoidal Steady-State Analysis - nodal analysis super node problem solution 2

Last Answer : Sinusoidal Steady-State Analysis - nodal analysis super node problem solution 2

Description : Sinusoidal Steady-State Analysis - nodal analysis super node problem solution

Last Answer : Sinusoidal Steady-State Analysis - nodal analysis super node problem solution

Description : Series parallel resistances problem solution

Last Answer : Series parallel resistances problem solution