Please Log in or Register for more.


174 views

1 Answer

Answer :

The short circuit in any winding of the transformer is the result of impulse voltage.

Like 0 like

Please log in or register to answer this question.

Related Questions









Last Answer : Low voltage side is short circuited.

Show More

163 views 1 answer








Last Answer : Primary is high voltage side and Secondary is low Voltage side.

Show More

123 views 1 answer








Last Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Show More

169 views 1 answer







State advantages of short pitch winding over full pitch winding in alternators. 
Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Show More

478 views 1 answer







If the % reactance upto the fault point is 20%, then the short circuit current will be
Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Show More

3.0k views 1 answer







In which fault the maximum short circuit current occurs?
Last Answer : In three phase bolted fault the maximum short circuit occurs.

Show More

130 views 1 answer








Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Show More

215 views 1 answer







A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts
Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Show More

223 views 1 answer








Last Answer : Primary winding of a transformer could either be a low voltage or high voltage winding.

Show More

86 views 1 answer








Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

Show More

197 views 1 answer








Last Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.

Show More

156 views 1 answer







Describe the difference between an open circuit and a short circuit.
Last Answer : Open circuit means the wire is cut meaning power will not flow and close circuit means wire is not cut and hence power will flow.Short circuit is the same as close circuit

Show More

7.8k views 3 answers







The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents
Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Show More

193 views 1 answer







Which of the following are known as the short circuit parameters of a 2- port network? (A) Z- parameters. (B) H- parameters. (C) Y- parameters. (D) A,B,C,D, parameters.
Last Answer : Which of the following are known as the short circuit parameters of a 2- port network? (A) Z- parameters. (B) H- parameters. (C) Y- parameters. (D) A,B,C,D, parameters.

Show More

90 views 1 answer








Last Answer : Short circuit test on transformers is conducted to determine copper losses.

Show More

218 views 1 answer







What can cause a short circuit?

Show More

63 views 0 answers








Last Answer : Reactance relay is preferred for phase fault on short transmission line.

Show More

110 views 1 answer







Equivalent circuit of transformer
Last Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

Show More

381 views 2 answers







 An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 
Last Answer :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Show More

259 views 1 answer







During open circuit test of a transformer?
Last Answer : During open circuit test of a transformer primary is supplied rated voltage.

Show More

110 views 1 answer







116 views 1 answer








Last Answer : Primary side is low voltage side and secondary side is high voltage side.

Show More

121 views 1 answer








Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Show More

234 views 1 answer







21 views 0 answers








Last Answer : It is the wire wound around a aluminium metal it is found commonly in transformers or motors

Show More

106 views 1 answer







Damper winding in a synchronous motor
Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Show More

87 views 1 answer







A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer
Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Show More

3.4k views 1 answer







A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Show More

331 views 1 answer







A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively
Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Show More

588 views 1 answer







Damper winding is provided in 3 phase synchronous motors to :
Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Show More

93 views 1 answer







Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper
Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Show More

621 views 1 answer








Last Answer : Wave winding is composed of that even number which is exact multiple of poles + 2.

Show More

90 views 1 answer








Last Answer : Lap winding is composed of any even number of conductors.

Show More

129 views 1 answer








Last Answer : In D.C. generators, lap winding is used for low voltage, high current.

Show More

94 views 1 answer








Last Answer : In the case of lap winding resultant pitch is difference of front and back pitches.

Show More

122 views 1 answer








Last Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Show More

665 views 1 answer








Last Answer : In lap winding, the number of brushes is always same as the number of poles.

Show More

323 views 1 answer








Last Answer : The resistance of armature winding depends on length of conductor, cross-sectional area of the conductor, number of conductors.

Show More

212 views 1 answer








Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Show More

355 views 1 answer








Last Answer : The starting winding of a single-phase motor is placed in stator.

Show More

115 views 1 answer








Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Show More

222 views 1 answer








Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Show More

110 views 1 answer








Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Show More

83 views 1 answer








Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Show More

145 views 1 answer








Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Show More

72 views 1 answer







The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?
Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Show More

116 views 1 answer








Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Show More

875 views 1 answer








Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Show More

207 views 1 answer








Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Show More

710 views 1 answer






Show More⇦ PreviousNext ⇨