1 Answer

Answer :

The short circuit in any winding of the transformer is the result of impulse voltage.

Related questions

Last Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Description : State advantages of short pitch winding over full pitch winding in alternators. 

Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Description : If the % reactance upto the fault point is 20%, then the short circuit current will be

Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Description : In which fault the maximum short circuit current occurs?

Last Answer : In three phase bolted fault the maximum short circuit occurs.

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Description : Describe the difference between an open circuit and a short circuit.

Last Answer : Open circuit means the wire is cut meaning power will not flow and close circuit means wire is not cut and hence power will flow.Short circuit is the same as close circuit

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : Which of the following are known as the short circuit parameters of a 2- port network? (A) Z- parameters. (B) H- parameters. (C) Y- parameters. (D) A,B,C,D, parameters.

Last Answer : Which of the following are known as the short circuit parameters of a 2- port network? (A) Z- parameters. (B) H- parameters. (C) Y- parameters. (D) A,B,C,D, parameters.

Last Answer : Short circuit test on transformers is conducted to determine copper losses.

Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Last Answer : Primary winding of a transformer could either be a low voltage or high voltage winding.

Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

Last Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.

Last Answer : Reactance relay is preferred for phase fault on short transmission line.

Description : Equivalent circuit of transformer

Last Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

Description :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Last Answer :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Description : During open circuit test of a transformer?

Last Answer : During open circuit test of a transformer primary is supplied rated voltage.

Last Answer : Primary side is low voltage side and secondary side is high voltage side.

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Last Answer : It is the wire wound around a aluminium metal it is found commonly in transformers or motors

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Description : Damper winding is provided in 3 phase synchronous motors to :

Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Wave winding is composed of that even number which is exact multiple of poles + 2.

Last Answer : Lap winding is composed of any even number of conductors.

Last Answer : In D.C. generators, lap winding is used for low voltage, high current.

Last Answer : In the case of lap winding resultant pitch is difference of front and back pitches.

Last Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Last Answer : In lap winding, the number of brushes is always same as the number of poles.

Last Answer : The resistance of armature winding depends on length of conductor, cross-sectional area of the conductor, number of conductors.

Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Last Answer : The starting winding of a single-phase motor is placed in stator.

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.