Over voltage protection is recommended for hydro-electric generators, steam turbine generators, gas turbine generators.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Show More

2.6k views 1 answer







Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker
Last Answer : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Show More

260 views 1 answer








Last Answer : In over compounded generator, full load terminal voltage is more than no load terminal voltage.

Show More

114 views 1 answer







What is meant by flash over voltage?

Show More

65 views 0 answers








Last Answer : Overfluxing protection is recommended for generator transformer of the power plant.

Show More

79 views 1 answer







Blind spot is a point in the zones of protection where
Last Answer : Blind spot is a point in the zones of protection where No protection is available.

Show More

665 views 1 answer







A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay
Last Answer : D

Show More

548 views 2 answers







A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines
Last Answer : A negative sequence relay is used for protection of Generator 

Show More

627 views 1 answer







For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester
Last Answer : For protection of rotating machines against lightning surges combination of lightning arrester and capacitor is used. 

Show More

4.6k views 1 answer







Reactance relay is normally preferred for protection against
Last Answer : Reactance relay is normally preferred for protection against earth faults

Show More

120 views 1 answer







Surge absorbers are used for protection against
Last Answer : Surge absorbers are used for protection against low voltage high frequency oscillations

Show More

3.0k views 1 answer








Last Answer : Protection by fuses is generally not used beyond 100 A .

Show More

173 views 1 answer








Last Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Show More

157 views 1 answer








Last Answer : The single phasing relays are used for the protection of three phase motors.

Show More

300 views 1 answer








Last Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Show More

396 views 1 answer








Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Show More

94 views 1 answer








Last Answer : The delay fuses are used for the protection of motors.

Show More

101 views 1 answer








Last Answer : A thermal protection switch can protect against overload.

Show More

233 views 1 answer







Primary and Backup Protection
Last Answer : Primary and Backup Protection  B,D,G,I are the primary protection. A,C,H,J are the backup protection. About 90% of faults are clear by Primary Protection. So ... ordinated backup (primary is at various station  and backup is at control room with computer)

Show More

403 views 1 answer







The surge impedance for over head line is taken as  (1) 10-20 ohms (2) 50-60 ohms (3) 100-200 ohms (4) 1000-2000 ohms
Last Answer : The surge impedance for over head line is taken as 100-200 ohms

Show More

108 views 1 answer







In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized
Last Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Show More

123 views 1 answer







Explain in detail over-voltage protection.
Last Answer : Over-voltage protection: Over-voltage protection to the thyristor is provided using: i) R-C Snubber circuit ii) Non-linear resistor Thyrector A) Snubber Circuit: It is basically a ... returns to its high resistance state. Thyrector is normally placed across the supply terminals.

Show More

2.6k views 1 answer







Can anyone recommend a good, durable protection case for iPod Touch 4th gen?
Last Answer : I would highly recommend an Otterbox case. I have the Defender series case for my 3gen iPod touch. It's not perfect, but it provides better protection than any other case I've seen, and I like the ... ago, but that was only because I dropped my iPod and the case cracked. The ipod was fine though.

Show More

5 views 1 answer







What is the purpose of Overload Protection in a motor circuit?
Last Answer : Ans. The Overload Protection is used in a motor circuit to protect it from sustained over currents.

Show More

54 views 1 answer







Protection scheme for internal faults in a three phase star delta connected transformer

Show More

2 views 0 answers







Limitations of differential protection scheme of the altanetor

Show More

11 views 0 answers







Car Leather Protection
Last Answer : Your girlfriend and your leather car interior have many things in common. Both are tough but incredibly sensitive. Both are cold and are very hard to please. Both need a lot of attention and ... differences too. Unlike your girlfriend, leather is not something you want to get down and dirty with.

Show More

12 views 1 answer







3 phase 11KV to 4 10000 KVA alternator has neutral Earth through a resistance of 1 ohm the machine has current balance protection while operate upon of balance Karan exceed 18% of full load determine percentage of winding and protected against ground fault

Show More

25 views 0 answers







State any two advantages of MCB over Fuse. State the standard specifications of MCB available in the market.  
Last Answer : Following advantages of MCB over Fuse: 1. No need of replacement of fuse wire. 2. Manually restore of supply is simple. 3. Fault understanding by visual inspection 4. More safe than fuse The standard specifications of ... 6A, 10A,16A,20A, 25A, 30A, 32A, 40A, 50A, 60A and 63A 6. 250V and 450 v

Show More

194 views 1 answer







Select insulating materials for following parts : (i) Insulation between heating element and base plate of electric iron. (ii) Insulation used over copper or aluminium conductor used for making coils. (iii) Transformer bushings. (iv) Insulation between transmission line and pole.
Last Answer : Parts Insulating Materials  Insulation between heating element and base plate of electric iron. Mica Insulation used over copper or aluminium conductor used for making coils.  ... Transformer bushings Porcelain  Insulation between transmission line and pole. Porcelain

Show More

199 views 1 answer







State advantages of short pitch winding over full pitch winding in alternators. 
Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Show More

478 views 1 answer







What do you mean by active filter? State its advantages over passive filter . Define pass band & stop band with respect to filter.
Last Answer : Active Filter: Active Filter is formed by using active element along with the passive components.  Advantages of Active filter over Passive filter: High value of pass band gain can be obtained. It is ... pass band.  Stop Band Filter: The frequency range which is attenuated is known as stop band.

Show More

126 views 1 answer







What is the advantage of AC over DC electrical transmission?

Show More

82 views 0 answers







State two advantages of digital system over analog system.
Last Answer : 1. They are less susceptible to noise. 2. The effect of fluctuation in the characteristic of the components, ageing of components etc. is very small in digital circuits. 3. Digital circuits have capability of memory which makes them suitable for computers. 4. More accurate.

Show More

128 views 1 answer







Thyristor can be protected from over voltages by using
Last Answer : Thyristor can be protected from over voltages by using Voltage clamping device

Show More

108 views 1 answer







The main advantage of AC over DC is:  (A) Conversion flexibility from one voltage level to other (B) AC can be easily converted into DC by using a rectifier (C) AC is easy to maintain & can be easily distributed at long distances (D) All of the above
Last Answer : Ac is easy to maintain and ac can be easily converted to dc by rectifier .There is no commutator for conversion in ac that's why ac machines are weight less and more efficiency.ac machines occupy less space than dc .

Show More

144 views 2 answers








Last Answer : An over excited synchronous motor on noload is known as synchronous condenser.

Show More

77 views 1 answer







Explain the significance of over modulation.

Show More

53 views 0 answers







The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods
Last Answer : The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods

Show More

104 views 1 answer







For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is
Last Answer : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is 25 x 25

Show More

2.2k views 1 answer








Last Answer : The under voltage relay can be used for generators, busbars, transformers, motors.

Show More

68 views 1 answer








Last Answer : The contacts of high voltage switches used in power system are submerged in oil. The main purpose of the oil is to extinguish the arc.

Show More

177 views 1 answer








Last Answer : The arc voltage produced in A.C. circuit breaker is always in phase with the arc current.

Show More

317 views 1 answer








Last Answer : The voltage appearing across the contacts after opening of the circuit breaker is called recovery voltage.

Show More

419 views 1 answer








Last Answer : In order that current should flow without causing excessive heating or voltage drop, the relay contacts should have low contact resistance, be clean and smooth, be of sufficient size and proper shape.

Show More

153 views 1 answer







Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission
Last Answer : (a) Increase of short-circuit current of the system

Show More

20 views 1 answer







What should I look for in buying a carbon monoxide detector?
Last Answer : I think the best is a multipurpose smoke detector and carbon monoxide detector wired in with battery back up. If you have old smoke detectors you might want to consider this. Otherwise, you can get a plug ... and still want a monoxide detector, so then the plug in is a nice addition in that case.

Show More

1 view 1 answer







Why don't I need a welding mask when I watch a welding video on YouTube?
Last Answer : because there are no actual sparks? because the brightness of the screen is limited? why do you not go blind when you look at a painting of the sun?

Show More

1 view 1 answer







How often would you wax a new vehicle?
Last Answer : Never.

Show More

1 view 1 answer







What types of STDs do lesbians need to protect themselves from?
Last Answer : Paper cuts from the scissor party?

Show More

2 views 1 answer






Show More⇦ PreviousNext ⇨