1 Answer

Answer :

Over voltage protection is recommended for hydro-electric generators, steam turbine generators, gas turbine generators.

Related questions

Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Description : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Last Answer : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Last Answer : In over compounded generator, full load terminal voltage is more than no load terminal voltage.

Description : What is meant by flash over voltage?

Last Answer : Overfluxing protection is recommended for generator transformer of the power plant.

Description : Blind spot is a point in the zones of protection where

Last Answer : Blind spot is a point in the zones of protection where No protection is available.

Description : A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

Last Answer : D

Description : A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

Last Answer : A negative sequence relay is used for protection of Generator 

Description : For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester

Last Answer : For protection of rotating machines against lightning surges combination of lightning arrester and capacitor is used. 

Description : Reactance relay is normally preferred for protection against

Last Answer : Reactance relay is normally preferred for protection against earth faults

Description : Surge absorbers are used for protection against

Last Answer : Surge absorbers are used for protection against low voltage high frequency oscillations

Last Answer : Protection by fuses is generally not used beyond 100 A .

Last Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Last Answer : The single phasing relays are used for the protection of three phase motors.

Last Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Last Answer : The delay fuses are used for the protection of motors.

Last Answer : A thermal protection switch can protect against overload.

Description : Primary and Backup Protection

Last Answer : Primary and Backup Protection  B,D,G,I are the primary protection. A,C,H,J are the backup protection. About 90% of faults are clear by Primary Protection. So ... ordinated backup (primary is at various station  and backup is at control room with computer)

Description : The surge impedance for over head line is taken as  (1) 10-20 ohms (2) 50-60 ohms (3) 100-200 ohms (4) 1000-2000 ohms

Last Answer : The surge impedance for over head line is taken as 100-200 ohms

Description : In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized

Last Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Description : Explain in detail over-voltage protection.

Last Answer : Over-voltage protection: Over-voltage protection to the thyristor is provided using: i) R-C Snubber circuit ii) Non-linear resistor Thyrector A) Snubber Circuit: It is basically a ... returns to its high resistance state. Thyrector is normally placed across the supply terminals.

Description : Can anyone recommend a good, durable protection case for iPod Touch 4th gen?

Last Answer : I would highly recommend an Otterbox case. I have the Defender series case for my 3gen iPod touch. It's not perfect, but it provides better protection than any other case I've seen, and I like the ... ago, but that was only because I dropped my iPod and the case cracked. The ipod was fine though.

Description : What is the purpose of Overload Protection in a motor circuit?

Last Answer : Ans. The Overload Protection is used in a motor circuit to protect it from sustained over currents.

Description : Protection scheme for internal faults in a three phase star delta connected transformer

Description : Limitations of differential protection scheme of the altanetor

Description : Car Leather Protection

Last Answer : Your girlfriend and your leather car interior have many things in common. Both are tough but incredibly sensitive. Both are cold and are very hard to please. Both need a lot of attention and ... differences too. Unlike your girlfriend, leather is not something you want to get down and dirty with.

Description : 3 phase 11KV to 4 10000 KVA alternator has neutral Earth through a resistance of 1 ohm the machine has current balance protection while operate upon of balance Karan exceed 18% of full load determine percentage of winding and protected against ground fault

Description : State any two advantages of MCB over Fuse. State the standard specifications of MCB available in the market.  

Last Answer : Following advantages of MCB over Fuse: 1. No need of replacement of fuse wire. 2. Manually restore of supply is simple. 3. Fault understanding by visual inspection 4. More safe than fuse The standard specifications of ... 6A, 10A,16A,20A, 25A, 30A, 32A, 40A, 50A, 60A and 63A 6. 250V and 450 v

Description : Select insulating materials for following parts : (i) Insulation between heating element and base plate of electric iron. (ii) Insulation used over copper or aluminium conductor used for making coils. (iii) Transformer bushings. (iv) Insulation between transmission line and pole.

Last Answer : Parts Insulating Materials  Insulation between heating element and base plate of electric iron. Mica Insulation used over copper or aluminium conductor used for making coils.  ... Transformer bushings Porcelain  Insulation between transmission line and pole. Porcelain

Description : State advantages of short pitch winding over full pitch winding in alternators. 

Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Description : What do you mean by active filter? State its advantages over passive filter . Define pass band & stop band with respect to filter.

Last Answer : Active Filter: Active Filter is formed by using active element along with the passive components.  Advantages of Active filter over Passive filter: High value of pass band gain can be obtained. It is ... pass band.  Stop Band Filter: The frequency range which is attenuated is known as stop band.

Description : What is the advantage of AC over DC electrical transmission?

Description : State two advantages of digital system over analog system.

Last Answer : 1. They are less susceptible to noise. 2. The effect of fluctuation in the characteristic of the components, ageing of components etc. is very small in digital circuits. 3. Digital circuits have capability of memory which makes them suitable for computers. 4. More accurate.

Description : Thyristor can be protected from over voltages by using

Last Answer : Thyristor can be protected from over voltages by using Voltage clamping device

Description : The main advantage of AC over DC is:  (A) Conversion flexibility from one voltage level to other (B) AC can be easily converted into DC by using a rectifier (C) AC is easy to maintain & can be easily distributed at long distances (D) All of the above

Last Answer : Ac is easy to maintain and ac can be easily converted to dc by rectifier .There is no commutator for conversion in ac that's why ac machines are weight less and more efficiency.ac machines occupy less space than dc .

Last Answer : An over excited synchronous motor on noload is known as synchronous condenser.

Description : Explain the significance of over modulation.

Description : The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods

Last Answer : The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods

Description : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is

Last Answer : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is 25 x 25