1 Answer

Answer :

Load factor of a power station is defined as average load/maximum demand.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : Load factor of a power station is generally less than unity.

Show More

107 views 1 answer







Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh
Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Show More

148 views 1 answer








Last Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Show More

169 views 1 answer








Last Answer : Demand factor is defined as maximum demand/connected load.

Show More

76 views 1 answer







A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging
Last Answer : 0

Show More

5.1k views 3 answers







In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle
Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Show More

340 views 1 answer








Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Show More

296 views 2 answers







Minimum voltage regulation occurs when the power factor of the load is?
Last Answer : Minimum voltage regulation occurs when the power factor of the load is leading.

Show More

221 views 1 answer







If the load of the normally excited synchronous motor is increased the power factor will?
Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Show More

150 views 1 answer







The synchronous motor which works on leading power factor and does not drive any mechanical load is called?
Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Show More

162 views 1 answer







In order to have a lower cost of electrical energy generation the load factor  (1) and the diversity factor should be low (2) should be low but the diversity factor should be high (3) should be high but the diversity factor should be low (4) and the diversity factor both should be high
Last Answer : In order to have a lower cost of electrical energy generation the load factor and the diversity factor both should be high

Show More

134 views 1 answer








Last Answer : Peak load plant can never have 100 percent load factor.

Show More

143 views 1 answer








Last Answer : In two part tariff, variation in load factor will affect operating or running charges.

Show More

79 views 1 answer








Last Answer : High load factor indicates total plant capacity is utilised for most of the time.

Show More

101 views 1 answer








Last Answer : The load factor of domestic load is usually 10 to 15%.

Show More

151 views 1 answer








Last Answer : An induction motor has relatively high power factor at near full load.

Show More

91 views 1 answer








Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Show More

183 views 1 answer








Last Answer : For a consumer the most economical power factor is generally 0.95 lagging .

Show More

208 views 1 answer








Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Show More

115 views 1 answer













Can a synchronous condenser improve power factor?
Last Answer : Yes, synchronous condenser can improve power factor.

Show More

90 views 1 answer







What is the maximum value of power factor?
Last Answer : 1 is the maximum value of power factor.

Show More

118 views 1 answer







Load factor is the  (1) Ratio of maximum load on the station to sum of consumer's maximum load.  (2) Ratio of average demand to maximum demand.  (3) Factor used for increasing load.  (4) Reciprocal of (1).
Last Answer : Load factor is the Ratio of average demand to maximum demand. 

Show More

101 views 1 answer







The load duration curve for unity load factor will be of  (1) Rectangular shape (2) Triangular shape (3) L -shape (4) I -shape
Last Answer : The load duration curve for unity load factor will be of Rectangular shape

Show More

1.5k views 1 answer







How Do I Build a Low Power FM Radio Station?
Last Answer : How Do I Build a Low Power FM Radio Station? A low power FM radio station offers individuals or small groups the ability to go on the air and communicate with the general public using FM radio ... FCC or your local government to determine which, if any FM frequencies you are allowed to transmit on.

Show More

8 views 1 answer







Compare the Nuclear power station with Hydro power station. 
Last Answer : SR. No.  Points Nuclear Power plant  Hydro Power station  1 Site/ Location Where there is ample supply of water is available, away from thickly populated areas to avoid radioactive ... Field Application As base load  Used as base load during as well as peak load 

Show More

75 views 1 answer







Classify condensers used in thermal power station. Explain each type in brief. 
Last Answer : Types of condenser: Classification: 1. Jet Condenser (Mixing Type) 2. Surface condenser (non Mixing type)  Explanation:-   1. Jet Condenser (Mixing Type) In Jet condenser the steam ... there in no direct contact between the steam and cooling water. This condensate is reused in boiler. 

Show More

136 views 1 answer







Explain the working of Hydro power station with schematic layout. 
Last Answer : Working of Hydro- Electric Power Plant: Water stored at high level by constructing dam across river. This stored water has potential energy. This stored water is passed to run the water ... energy and Alternator is coupled to water turbine which converts mechanical energy into electrical energy. 

Show More

103 views 1 answer







"Efficiency of thermal power station is low". — Justify. 
Last Answer : Justification: Efficiency of thermal power station is low":- Overall efficiency of T.P.P depends upon efficiency of boiler, turbine and alternator. The heat produced due to combustion of coal ... losses in thermal power plant is 71%, So efficiency of thermal power plant is less about 29% 

Show More

104 views 1 answer







Applications of Diesel power station
Last Answer : Applications of Diesel Power Station:  1. It can be used as a standby (emergency) power plant to maintain continuity of supply. (Incase failure of main supply like hospital, Telephone exchange Radio ... 10. Diesel plants are widely used for generating power ranging from 100 to 5,000 H.P. 

Show More

67 views 1 answer







List out main components of Diesel power station. 
Last Answer : Main components of Diesel power station: 1) Diesel Engine 2) Engine Air intake system 3) Engine Fuel System 4) Engine Exhaust system 5) Engine cooling system 6) Engine Lubricating system 7) Engine Starting system 8) Diesel Engine Generator (Alternator) 

Show More

105 views 1 answer







State the function of following components of a nuclear power station: i) Moderator ii) Shielding iii) Control rod iv) Coolant 
Last Answer : i) Function of Moderator :- Moderator is to moderate or reduce the speed of fast neutron to help the fission process.  ii) Function of sheilding : Shielding is to protect environment, ... from reactor core and transfer it in heat exchanger for producing steam at high pressure and temperature. 

Show More

123 views 1 answer







State the types of radioactive waste generated in a nuclear power station. Explain the methods employed for their disposal.
Last Answer : Types of radioactive waste: The waste produced in nuclear power plant is in the form of solid, liquid & gases, 1. Solid Waste Disposal:-  Solid wastes removed from the reactor are very ... are measured. If it is safe then released to atmosphere at high level through large height chimney.

Show More

129 views 1 answer







"Hydro electric power station are not perennial power station". Justify.
Last Answer : Justification: The water utilized by the hydro power plants comes mostly from storage dams/reservoirs which get filled up during the monsoon rainy season. Such reservoirs are utilized for supplying ... are important. Hence "Hydro electric power stations are not perennial power station" 

Show More

89 views 1 answer







List and state any four limitations of inter connected power station.
Last Answer : Limitations of inter connected power station:- 1) Initial cost of infrastructure of transmission line increases as length increases. 2) Interconnection required more automation which increases cost on ... capacity. But in absence of surplus power merits of interconnection cannot be obtain.

Show More

47 views 1 answer







State the functions of fuel system and exhaust system of a diesel power station.
Last Answer : Fuel system: It supplies fuel to engine for combustion purpose. It consists of Fuel Pump: - It supplies fuel to engine for combustion purpose. Strainer: - Are provided to remove suspended impurities and ... most of the noise. Chimney:- To exhaust gases in the atmosphere as high as possible. 

Show More

96 views 1 answer







State the function of cooling tower and condenser in thermal power station.
Last Answer : 1. Condenser:   Function of condenser is to convert exhaust steam again into water by reducing its temperature with the help of cold water. Also it reduces back pressure of steam turbine 2 ... tower : The function of cooling tower is to reduce the temperature of water coming from condenser.

Show More

315 views 1 answer







State the purpose of surge tank and spill way in hydroelectric power station.
Last Answer : Surge tank :- A surge tank is the small reservoir or tank. It is open at the top. It is installed near Vale house of turbine. It avoids water hammer effect when load on turbine reduces. (It ... ; during floods etc. In this way spill way avoids damage of dam due to excess pressure of water.

Show More

92 views 1 answer







State any four factors governing Selection of site for thermal power station. 
Last Answer : Following Factors are to be considered:- 1. It should locate near coal mine. 2. Sufficient quantity of water should be available. 3. Sufficient large space should be available. 4. It should be located ... laws of the land and the town planning. 14. The interests of national defense must be served.

Show More

186 views 2 answers







Write down any two advantages of nuclear power station.
Last Answer : Advantages of nuclear power station :-  1) Fuel required: Fuel requirment of Nuclear Power Plant is less than Thermal Power Plant. So it reduces transportation cost of fuel and space required for fuel storage ... By use of nuclear fuel.,it saves the other fossile fuels like-coal, gas, oil, etc.

Show More

106 views 2 answers








Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Show More

94 views 1 answer








Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Show More

98 views 1 answer







The following formula is correct:  (A) Load factor=Average load for a period/ Peak load for the same period  (B) Load factor=Average load for a period x Peak load for the same period  (C) Load factor=Average load for a period + Peak load for the same period  (D) All of the above
Last Answer : The following formula is correct: (A) Load factor=Average load for a period/ Peak load for the same period (B) Load factor=Average load for a period x Peak load for the same period (C) Load factor=Average load for a period + Peak load for the same period (D) All of the above

Show More

67 views 1 answer







State why nuclear power plants are used as base load plants and diesel power plants as a peak load plant. 
Last Answer : 1. Because of following points Nuclear power plant used as base load power plant:-  1. Nuclear power plants is very economical for producing bulk amount of electric power 2. Nuclear power plant is reliable ... . The plants can be put on load easily. 4. Diesel engines take less time to make OFF.

Show More

119 views 1 answer







Generally in a power system network, the load is represented as a :  (A) Constant power in both load flow study and in stability study  (B) Constant power in load flow study and constant ... impedance in load flow study  (D) Constant impedance in both load flow study and in stability study
Last Answer : Generally in a power system network, the load is represented as a : Constant power in load flow study and constant impedance in stability study 

Show More

117 views 1 answer







In tuned power lines, on load :  (A) the receiving end voltage is numerically equal to the sending end voltage  (B) the receiving end current is numerically equal to the sending end current  (C) there is no voltage drop  (D) all the above
Last Answer : In tuned power lines, on load :  (A) the receiving end voltage is numerically equal to the sending end voltage  (B) the receiving end current is numerically equal to the sending end current  (C) there is no voltage drop  (D) all the above

Show More

79 views 1 answer







Load compensation in power systems is a process to :  (A) Maintain better voltage profile (B) Increase short circuit capacity of the system (C) Generate required harmonics for loads like arc furnaces (D) Compensate for the line reactance
Last Answer : Load compensation in power systems is a process to : Maintain better voltage profile

Show More

110 views 1 answer







A 3 -phase, fully controlled, converter is feeding power into a DC load at a constant current of 150 A, the rms value of the current flowing through each thyristor of the converter is
Last Answer : Please show the solution for this question

Show More

515 views 2 answers







The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is (A) zero (B) 0.5 (C) between zero and 0.5 (D) between 0.5 and unity
Last Answer : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is between 0.5 and unity

Show More

171 views 1 answer







The maximum load that a power transformer can carry is limited by its?
Last Answer : The maximum load that a power transformer can carry is limited by its voltage ratio.

Show More

133 views 1 answer