For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Like 0 like

Please log in or register to answer this question.

Related Questions








Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh
Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Show More

148 views 1 answer








Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Show More

185 views 1 answer








Last Answer : Load factor of a power station is generally less than unity.

Show More

107 views 1 answer








Last Answer : Load factor of a power station is defined as average load/maximum demand.

Show More

321 views 1 answer








Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Show More

115 views 1 answer







What is the maximum value of power factor?
Last Answer : 1 is the maximum value of power factor.

Show More

118 views 1 answer








Last Answer : In an interconnected system, the diversity factor of the whole system increases.

Show More

193 views 1 answer







Diversity factor has direct effect on the?
Last Answer : Diversity factor has direct effect on the fixed cost of unit generated.

Show More

187 views 1 answer








Last Answer : An induction motor has relatively high power factor at near full load.

Show More

91 views 1 answer







The following formula is correct:  (A) Diversity factor =1 / Coincidence Factor  (B) Diversity factor =1 x Coincidence Factor  (C) Diversity factor =1 - Coincidence Factor  (D) All of the above
Last Answer : The following formula is correct:  (A) Diversity factor =1 / Coincidence Factor  (B) Diversity factor =1 x Coincidence Factor  (C) Diversity factor =1 - Coincidence Factor  (D) All of the above

Show More

84 views 1 answer







The knowledge of diversity factor helps in computing  (1) Plant capacity (2) Average load (3) Units (kWh) generated (4) Peak demand
Last Answer : The knowledge of diversity factor helps in computing Plant capacity

Show More

567 views 1 answer








Last Answer : In a power plant if the maximum demand on the plant is equal to the plant capacity, then plant reserve capacity will be zero.

Show More

273 views 1 answer







Power factor of the system is kept high?
Last Answer : Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

Show More

143 views 1 answer







What is the advantage of high power factor?
Last Answer : Reduced copper losses Smaller conductor size Improve voltage regulation Increase system capability Less energy bill

Show More

103 views 2 answers








Last Answer : High load factor indicates total plant capacity is utilised for most of the time.

Show More

101 views 1 answer







A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?
Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Show More

231 views 1 answer








Last Answer : For a consumer the most economical power factor is generally 0.95 lagging .

Show More

209 views 1 answer







Can a synchronous condenser improve power factor?
Last Answer : Yes, synchronous condenser can improve power factor.

Show More

90 views 1 answer







How Do I Build a Low Power FM Radio Station?
Last Answer : How Do I Build a Low Power FM Radio Station? A low power FM radio station offers individuals or small groups the ability to go on the air and communicate with the general public using FM radio ... FCC or your local government to determine which, if any FM frequencies you are allowed to transmit on.

Show More

8 views 1 answer







Compare the Nuclear power station with Hydro power station. 
Last Answer : SR. No.  Points Nuclear Power plant  Hydro Power station  1 Site/ Location Where there is ample supply of water is available, away from thickly populated areas to avoid radioactive ... Field Application As base load  Used as base load during as well as peak load 

Show More

75 views 1 answer







Classify condensers used in thermal power station. Explain each type in brief. 
Last Answer : Types of condenser: Classification: 1. Jet Condenser (Mixing Type) 2. Surface condenser (non Mixing type)  Explanation:-   1. Jet Condenser (Mixing Type) In Jet condenser the steam ... there in no direct contact between the steam and cooling water. This condensate is reused in boiler. 

Show More

136 views 1 answer







Explain the working of Hydro power station with schematic layout. 
Last Answer : Working of Hydro- Electric Power Plant: Water stored at high level by constructing dam across river. This stored water has potential energy. This stored water is passed to run the water ... energy and Alternator is coupled to water turbine which converts mechanical energy into electrical energy. 

Show More

104 views 1 answer







"Efficiency of thermal power station is low". — Justify. 
Last Answer : Justification: Efficiency of thermal power station is low":- Overall efficiency of T.P.P depends upon efficiency of boiler, turbine and alternator. The heat produced due to combustion of coal ... losses in thermal power plant is 71%, So efficiency of thermal power plant is less about 29% 

Show More

105 views 1 answer







Applications of Diesel power station
Last Answer : Applications of Diesel Power Station:  1. It can be used as a standby (emergency) power plant to maintain continuity of supply. (Incase failure of main supply like hospital, Telephone exchange Radio ... 10. Diesel plants are widely used for generating power ranging from 100 to 5,000 H.P. 

Show More

67 views 1 answer







List out main components of Diesel power station. 
Last Answer : Main components of Diesel power station: 1) Diesel Engine 2) Engine Air intake system 3) Engine Fuel System 4) Engine Exhaust system 5) Engine cooling system 6) Engine Lubricating system 7) Engine Starting system 8) Diesel Engine Generator (Alternator) 

Show More

105 views 1 answer







State the function of following components of a nuclear power station: i) Moderator ii) Shielding iii) Control rod iv) Coolant 
Last Answer : i) Function of Moderator :- Moderator is to moderate or reduce the speed of fast neutron to help the fission process.  ii) Function of sheilding : Shielding is to protect environment, ... from reactor core and transfer it in heat exchanger for producing steam at high pressure and temperature. 

Show More

126 views 1 answer







State the types of radioactive waste generated in a nuclear power station. Explain the methods employed for their disposal.
Last Answer : Types of radioactive waste: The waste produced in nuclear power plant is in the form of solid, liquid & gases, 1. Solid Waste Disposal:-  Solid wastes removed from the reactor are very ... are measured. If it is safe then released to atmosphere at high level through large height chimney.

Show More

129 views 1 answer







"Hydro electric power station are not perennial power station". Justify.
Last Answer : Justification: The water utilized by the hydro power plants comes mostly from storage dams/reservoirs which get filled up during the monsoon rainy season. Such reservoirs are utilized for supplying ... are important. Hence "Hydro electric power stations are not perennial power station" 

Show More

89 views 1 answer







List and state any four limitations of inter connected power station.
Last Answer : Limitations of inter connected power station:- 1) Initial cost of infrastructure of transmission line increases as length increases. 2) Interconnection required more automation which increases cost on ... capacity. But in absence of surplus power merits of interconnection cannot be obtain.

Show More

47 views 1 answer







State the functions of fuel system and exhaust system of a diesel power station.
Last Answer : Fuel system: It supplies fuel to engine for combustion purpose. It consists of Fuel Pump: - It supplies fuel to engine for combustion purpose. Strainer: - Are provided to remove suspended impurities and ... most of the noise. Chimney:- To exhaust gases in the atmosphere as high as possible. 

Show More

97 views 1 answer







State the function of cooling tower and condenser in thermal power station.
Last Answer : 1. Condenser:   Function of condenser is to convert exhaust steam again into water by reducing its temperature with the help of cold water. Also it reduces back pressure of steam turbine 2 ... tower : The function of cooling tower is to reduce the temperature of water coming from condenser.

Show More

315 views 1 answer







State the purpose of surge tank and spill way in hydroelectric power station.
Last Answer : Surge tank :- A surge tank is the small reservoir or tank. It is open at the top. It is installed near Vale house of turbine. It avoids water hammer effect when load on turbine reduces. (It ... ; during floods etc. In this way spill way avoids damage of dam due to excess pressure of water.

Show More

92 views 1 answer







State any four factors governing Selection of site for thermal power station. 
Last Answer : Following Factors are to be considered:- 1. It should locate near coal mine. 2. Sufficient quantity of water should be available. 3. Sufficient large space should be available. 4. It should be located ... laws of the land and the town planning. 14. The interests of national defense must be served.

Show More

187 views 2 answers







Write down any two advantages of nuclear power station.
Last Answer : Advantages of nuclear power station :-  1) Fuel required: Fuel requirment of Nuclear Power Plant is less than Thermal Power Plant. So it reduces transportation cost of fuel and space required for fuel storage ... By use of nuclear fuel.,it saves the other fossile fuels like-coal, gas, oil, etc.

Show More

107 views 2 answers








Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Show More

94 views 1 answer








Last Answer : For measurement of inductance having high value, we should use Hay's bridge.

Show More

169 views 1 answer








Last Answer : Large capacity generators are invariably hydrogen cooled.

Show More

95 views 1 answer








Last Answer : Generating capacity connected to the bus bars and ready to take load when switched on is known as spinning reserve.

Show More

177 views 1 answer







Draw the block diagram of regulated power supply, explain function of each block and draw waveforms of each stage.
Last Answer : 1. A step down transformer 2. A rectifier 3. A filter 4. A regulator Operation of Regulated Power Supply:- Step Down Transformer:- A step down transformer will ... regulator. A regulator will maintain the output constant even when changes at the input or any other changes occur.

Show More

2.0k views 3 answers







What is need of regulated power supply?
Last Answer : A regulated power supply is used to ensure that the output remains constant even if the input changes. But sometimes main supply voltage, load, and surrounding temperature keep changing and altering the ... power supply is needed that will accept an AC input and give a constant DC output.

Show More

136 views 3 answers







What is the Power Supply specification for 8085AH microprocessor? A) Single +5V supply with 10% voltage margins B) Dual +5V supply with 10% voltage margins C) Single +10V supply with 5% voltage margins D) Dual +5V supply with 5% voltage margins 
Last Answer : What is the Power Supply specification for 8085AH microprocessor? A) Single +5V supply with 10% voltage margins B) Dual +5V supply with 10% voltage margins C) Single +10V supply with 5% voltage margins D) Dual +5V supply with 5% voltage margins 

Show More

258 views 1 answer







Two 100W, 200V lamps are connected in series across a 200V supply. The total power consumed by each lamp will be in Watts
Last Answer : 4800

Show More

444 views 2 answers







The time period of third harmonic of power supply frequency, in milliseconds, is (A) 20 (B) 3.33 (C) 6.66 (D) 60
Last Answer : The time period of third harmonic of power supply frequency, in milliseconds, is 6.66 

Show More

540 views 1 answer








Last Answer : Overhead lines for power supply to tramcars are at a minimum height of 10 m.

Show More

2.6k views 1 answer








Last Answer : Rectifier is use in power supply to convert Alternating current (AC) to Direct Current (DC) .

Show More

109 views 1 answer








Last Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

Show More

119 views 1 answer








Last Answer : The adjustment of position of shading bands, in an energy meter is done to provide friction compensation.

Show More

199 views 1 answer








Last Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Show More

98 views 1 answer







What is the value of Beta in power BJT?
Last Answer : The beta value in power BJT is 5 to 10.

Show More

105 views 1 answer






Show More⇦ PreviousNext ⇨