1 Answer

Answer :

In a load curve the highest point represents peak demand.

Related questions

Last Answer : Load curve is useful in deciding the operating schedule of generating units, sizes of generating units, total installed capacity of the plant.

Last Answer : The area under a load curve gives energy consumed.

Last Answer : A load curve indicates average kWh (kW) energy consumption during the period.

Description : Explain with diagram load duration curve.

Last Answer : It is drawn from load curve. It is graph of load (MW/KW) arranged in descending order of magnitude with respect to time. 

Description : The load duration curve for unity load factor will be of  (1) Rectangular shape (2) Triangular shape (3) L -shape (4) I -shape

Last Answer : The load duration curve for unity load factor will be of Rectangular shape

Description : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Last Answer : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Description : The device which allows reverse power flow and withstands highest switch frequency is (A) GTO (B) MOSFET (C) IGBT (D) Inverter grade SCR

Last Answer : The device which allows reverse power flow and withstands highest switch frequency is MOSFET

Description : The ADC having highest conversion speed is (A) Dual-slope ADC (B) Successive approximation ADC (C) Flash ADC (D) Servo ADC

Last Answer : The ADC having highest conVersion speed is Flash ADC

Last Answer : Electric locomotive has the highest operational availability.

Description : Draw and explain integrated duration curve used in system operation. 

Last Answer : Diagram of integrated duration curve used in system operation: Explanation:  Integrated duration curve is obtained from load duration curve. It is drawn in between load on Y-axis in KW/MW and the X- ... a particular time of a day can also be shown on a curve which is called as mass curve. 

Description : In quadrilateral speed-time curve of electric traction system, the accelerations during successive time periods are ______ respectively.  (A) positive, negative and negative (B) positive, zero and negative (C) positive, positive and negative (D) positive, negative and zero

Last Answer : In quadrilateral speed-time curve of electric traction system, the accelerations during successive time periods are positive, negative and negative respectively. 

Description : In electric traction for a trapezoidal speed-time curve, the time period is (A) free running speed period = constant speed period (B) free running period = coasting period (C) free running period + coasting period = constant speed period (D) average speed period = scheduled speed period

Last Answer : In electric traction for a trapezoidal speed-time curve, the time period is free running period + coasting period = constant speed period

Description : Trapezoidal speed-time curve is (A) an exact representation of the conditions in Main-line traction service. (B) an exact representation of the conditions in Suburban traction service. (C) ... in Suburban traction service. (D) a close approximation of the conditions in Mainline traction service.

Last Answer : Trapezoidal speed-time curve is a close approximation of the conditions in Mainline traction service.

Last Answer : When a bogie negotiates a curve, reduction in adhesion occurs resulting in sliding. Thus sliding is acute when wheel base of axles is more, degree of curvature is more.

Description : write short notes on BH curve.

Last Answer : The B-H curve is the relation between Flux density B in Wb/m2 (on Y Axis) and H in AT/m (on X axis) It is also known as magnetization characteristics. This curve particularly useful ... occurs. At point A' material gets magnetically saturated and the curve becomes flat (parallel to X axis) 

Description : Compare base load plant with peak load plant. 

Last Answer : Sr.No. Points Base load plant Peak load plant  1 Definition The power plant which supplies base load of load curve is known as base load plant The power ... power station   Small capacity storage hydro, pumped storage hydro, gas, diesel power station. 

Last Answer : 1. Connected Load: It is the sum of load of all equipment's connected to supply system which are in use or not in use of each consumer. OR   The sum of connected load of all consumers ... is the maximum load which a consumer uses at a particular time period out of his total connected load. 

Description : In order to have a lower cost of electrical energy generation the load factor  (1) and the diversity factor should be low (2) should be low but the diversity factor should be high (3) should be high but the diversity factor should be low (4) and the diversity factor both should be high

Last Answer : In order to have a lower cost of electrical energy generation the load factor and the diversity factor both should be high

Last Answer : Nuclear power plant is invariably used as base load plant.

Last Answer : Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

Last Answer : Generating capacity connected to the bus bars and ready to take load when switched on is known as spinning reserve.

Last Answer : The increased load during summer months is due to increased use of fans and air conditioners.

Last Answer : Peak load plant can never have 100 percent load factor.

Last Answer : In two part tariff, variation in load factor will affect operating or running charges.

Last Answer : High load factor indicates total plant capacity is utilised for most of the time.

Last Answer : The load factor of domestic load is usually 10 to 15%.

Last Answer : Load factor of a power station is generally less than unity.

Last Answer : Load factor of a power station is defined as average load/maximum demand.

Description : What does an alpha male and female look like when compared to the omega man/woman?

Last Answer : I guess part of it is luck. To be alpha, obviously you need to be at least decent looking, and then the confidence is up to the person themselves.

Description : Single point Cutting tool signature

Last Answer : The shape of a tool is specified in a special sequence and this special sequence is called tool signature. The tool signature is given below (i) Back rake angle (ii) Side rake angle (iii) ... rake, end relief, side relief, end cutting edge, side cutting edge angle and 0.8 mm nose radius.

Description : Illustrate with neat wiring diagram a single lamp control by two point method.

Last Answer : Single lamp control by two point method:  This system is commonly used for stair case wiring. It consists of two way switches (the switch operates always in one of the two possible positions) the ... the person will change the position of switch S2, so that the lamp will be switched OFF'.

Description : A charge of 0.1 C moves past a given point every 0.01 s. How much is the current?

Last Answer : The current is 10.0A.  1ampere = 1 Coulomb per 1 second.  0.1Coulombs ÷ 0.01seconds = 10.0amperes.

Description : The operating point of a protective current transformer is near the

Last Answer : The operating point of a protective current transformer is near the Ankle point

Description : Blind spot is a point in the zones of protection where

Last Answer : Blind spot is a point in the zones of protection where No protection is available.

Description : If the % reactance upto the fault point is 20%, then the short circuit current will be

Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Last Answer : Three point starter can be used for both shunt and compound motor.

Last Answer : A three point starter is considered suitable for shunt as well as compound motors.

Description : what is the difference between four point starter and three point starter?

Last Answer : The shunt connection in four point starter is provided separately form the line where as in three point starter it is connected with line which is the drawback in three point starter.

Description : Single-phase mid-point controlled rectifier with RL load

Last Answer : Single-phase mid-point controlled rectifier with RL load : The circuit configuration of single-phase midpoint controlled rectifier is shown in the figure. During positive half-cycle of ... some part of next positive half-cycle of voltage with reversed polarity can appear across load.

Description : Explain MCB and ELCB with connection diagram supplying single phase load. 

Last Answer : OR OR Explanation: * MCB provides short circuit protection. * MCB provides overload protection * ELCB provides earth fault protection. * MCB is in series with ... occurs, the ELCB cuts off the power within the time of 0.1 sec. automatically to protect the personnel. 

Description : Class A Load Commutation

Last Answer : Class A: Load Commutation: The class A or load commutation (also called self-commutation or resonant commutation) is employed in thyristor circuits supplied from DC source. The commutating components include ... biased. Thus the zero-current and reverse-bias cause the thyristor to turn-off. 

Description : Single-phase Midpoint controlled rectifier with Resistive load

Last Answer : Single-phase Midpoint controlled rectifier with Resistive load:  1) During positive half cycle of AC supply, a is positive with respect to b , this makes T1 forward biased and T2 is reverse ... voltage reverses the polarity and T2 is turned off. The operation is as shown in waveforms.

Description : Define for polyphase circuit (i) Balanced load (ii) Unbalanced load. Draw one example circuit for each type of load.

Last Answer : i) Balanced Load: Balanced three phase load is defined as star or delta connection of three equal impedances having equal real parts and equal imaginary parts.  Example circuit:  ii) ... satisfy the condition of balance, then it is called as unbalanced load.  Example circuit:

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : Define the terms: i) Tariff ii) Fuel surcharge iii) Electricity Duty iv) Connected load

Last Answer : i) Tariff: The rate at which a consumer is charged for the consumption of electricity is called as tariff. OR The amount of money framed by the supplier for the supply of electrical energy ... is the total wattage of all appliances which are used by the consumer on his sanctioned connection. 

Description : Define the following terms related to tariff: (i) Connected load (ii) Unit consumed (iii) Fixed charges (iv) Electricity Tax 

Last Answer : (i) Connected load  It is the sum of the power ratings (Watts or kW or MW) of all devices and machines existing (installed) in the premises of consumer. It is used to decide the ... a percentage of the total electricity bill which includes all amounts that go to the electricity supply agency. 

Description : Define the following: i) Residential load ii) Industrial load

Last Answer : i) Residential load: The electrical load which is used in residential installation is called as residential load. E.g. incandescent lamp, florescent tube, fan ,5A socket &15A socket etc.   ii ... 3-ph any type of motor, electric furnace ,oven,welding transformer and any power load etc. 

Description : Compare base load plant with peak load plant on any two points.

Last Answer : Points Base load plant Peak load plant Definition The power plant which supplies base load of load curve is known as base load plant  The power plant which supplies ... ,thermal,nuclear power station Small capacity storage hydro,pumped storage hydro,gas,diesel power station.

Description : State why nuclear power plants are used as base load plants and diesel power plants as a peak load plant. 

Last Answer : 1. Because of following points Nuclear power plant used as base load power plant:-  1. Nuclear power plants is very economical for producing bulk amount of electric power 2. Nuclear power plant is reliable ... . The plants can be put on load easily. 4. Diesel engines take less time to make OFF.