1 Answer

Answer :

In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Related questions

Description : Why capacitors are used to improve power factor?

Last Answer :  Capacitors generate reactive power instead of that drawn from source which is required by inductive loads.so it reduce the reactive current which is drawn from source to be drawn from capacitor.This control in Electric bills cost.

Description : Can a synchronous condenser improve power factor?

Last Answer : Yes, synchronous condenser can improve power factor.

Last Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Description : Capacitors for power factor correction are rated in?

Last Answer : Capacitors for power factor correction are rated in kVAR.

Description : How does a capacitor improve power factor?

Last Answer : Every circuit are usually more inductive than capacitive.it means that the current lags by voltage at small angle.hence we have to compensate this situation so we use Capacitor then this lag is compensate ... angle becomes low and the value of cos(phase angle) is increase and hence power also max.

Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Last Answer : For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

Description : If we change the excitation of synchronous machine will it affect on power factor?

Last Answer : Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : The benefit of power factor correction in a power system is (A) lower power consumption (B) increased demand charge (C) reduced load carrying capabilities in existing lines (D) reduced voltage profile

Last Answer : The benefit of power factor correction in a power system is lower power consumption

Description : Power factor of the system is kept high?

Last Answer : Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

Last Answer : In an interconnected system, the diversity factor of the whole system increases.

Description : Grid distribution system

Last Answer : Grid distribution system:-  In this system, when the feeder or loop or ring is charged (energized) by two or more than two substations from two or more than two different generating stations then it is known as “Grid distribution system. In this system only one feeder is utilized at a time. 

Description : Define: primary and secondary distribution system 

Last Answer : i) Primary Distribution:  It is a 3-phase, 3-wire transmission line connected in between receiving substation to Distribution substation. OR It is link between receiving substation & ... substation to consumer line. OR It is link between distribution transformer substation & consumer. 

Description : State the losses in secondary distribution system. 

Last Answer : The losses in secondary distribution system: a) Technical losses: 1. Due to poor voltage 2. Due to unbalance load 3. Due poor quality of transformer & its components 4. Due to poor quality ... of induction type of energy meter. 3. Lack of administration. 4. Energy theft 5. Unmetered supply

Description : requirements of a distribution system

Last Answer : Following requirements of a distribution system.  1. Layout should be simple in design. 2. It should have less initial cost 3. The distribution system should have minimum distribution ... stability of existing distribution system. 15. Time required for completion of work should be less. 

Description : Why radial distribution system used for short distance ? 

Last Answer : Because of following disadvantages radial distribution system is not used for long distance:  Since there is only one feeder to DTC feed at one point so, 1) There is no reliability ... more time for fault finding & repairing Hence radial distribution system is used for short distance.

Description : Explain following techniques related to energy conservation in transmission and distribution system. (i) By balancing phase currents (ii) Variable technical losses (I2R losses).

Last Answer : (i) Balancing Phase currents: Proper (healthy balanced) three phase loads always draw equal currents in all lines but single phase loads in the 3 phase 4 wire system or loads connected between two ... . 11) Minimize I2R losses. 12) Balance the load currents. 13) Regulate the system voltages.

Description : The permissible voltage variation in transmission and distribution system is:  (A) ± 0.1% (B) ± 1% (C) ±10% (D) ± 25%

Last Answer : The permissible voltage variation in transmission and distribution system is: ±10%

Description : The main criterion for selection of the size of a radial distribution system is

Last Answer : The main criterion for selection of the size of a radial distribution system is voltage drop

Last Answer : An induction motor has relatively high power factor at near full load.

Last Answer : For a consumer the most economical power factor is generally 0.95 lagging .

Last Answer : Load factor of a power station is generally less than unity.

Last Answer : Load factor of a power station is defined as average load/maximum demand.

Description : What is the maximum value of power factor?

Last Answer : 1 is the maximum value of power factor.

Last Answer : In a power or distribution transformer about 10 percent end turns are heavily insulated to withstand the high voltage drop due to line surge produced by the shunting capacitance of the end turns.

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Last Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

Description : The synchronous motor will develop maximum power when the load angle is?

Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

Description : A control system having unit damping factor will give  (1) Oscillatory response (2) Undamped response (3) Critically damped response (4) No response

Last Answer : 1

Description : The damping factor of a particular system is unity, the system response will be

Last Answer : The damping factor of a particular system is unity, the system response will be critically damped

Description : How is marble floor installed?

Last Answer : After the cladding tiles made from natural marble began to appear on the market, it became possible to arrange real marble floors. Increasingly, marble floors can be found in residential mansions and ... . It is also desirable to treat the surface of the marble with a protective polymerizing film.

Description : Phase modifier is normally installed

Last Answer : Phase modifier is normally installed in case of long lines

Last Answer : An isolator is installed generally on both sides of a circuit breaker.

Last Answer : For cost and safety, the outdoor substations are installed for voltages above 33 kV.

Description : What is meant by Power factor?

Last Answer : Ans. Power factor means ratio of true power to apparent power. It is cosine of phase angle between voltage and current. Its value is 1 for Unity P.F. Loads, 0 to 1 lagging for inductive loads and o to 1 leading for capacitive loads.

Description : State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Last Answer : i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

Description : Briefly explain how the power factor of an inductive circuit can be improved.

Last Answer : As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

Description : Discuss how power factor tariff results into energy conservation.

Last Answer : Power factor tariff results into energy conservation: i) Applying incentives and penalties according to power factor is an effective way, which enables consumer to improve power factor so that he can ... finally leads to reduction in the current drawn by the load and helps for energy conservation.

Description : Draw and explain bulk correction method for power factor & control.

Last Answer : Bulk correction method for power factor & control: i) Here individual starter controls the capacitors located at distribution panel. ii) Centralized compensation is employed in large industrial plants where many ... capacitor units in steps to maintain P.F. more than preset limit (0.95). 

Description : State the incentives and penalties related with power factor tariff.

Last Answer : Incentives and penalties related with power factor tariff: In addition to basic tariff (Maximum Demand Tariff / KVA Maximum Demand Tariff / Load factor tariff) the tariff in which P.F. of ... industrial consumer/H.T/ commercial consumers with contract demand above 80 kw/ 100Kva/107 hp consumer.

Description : With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Last Answer : Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load.