Please Log in or Register for more.


92 views

1 Answer

Answer :

An induction motor has relatively high power factor at near full load.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : The power factor of a single-phase induction motor is usually lagging.

Show More

191 views 1 answer







A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?
Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Show More

169 views 1 answer







At which time power factor of the induction motor is low?
Last Answer : The power factor of the inducction motor is low at the time of starting as compare to while the induction motor is running.

Show More

151 views 1 answer








Last Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Show More

169 views 1 answer







Why does induction motor have high starting current?
Last Answer : In induction motor , the flux produce is quadrature to the applied voltage. Since when we are going to start motor , there is no flux present inside . So in order to lets say compensate it ... times of current to further increase flux. So that is reason for high starting current in induction motor

Show More

143 views 2 answers







Explain energy conservation technique “by improving power quality” for induction motor.
Last Answer : Energy conservation method in induction motor by improving power quality: Electrical energy can be conserved by improving the power quality. It can be achieved by avoiding voltage unbalance, maintaining ... losses can be minimized by using harmonic filter thus reducing the harmonics in the system.

Show More

3.6k views 2 answers







Power factor of the system is kept high?
Last Answer : Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

Show More

144 views 1 answer







What is the advantage of high power factor?
Last Answer : Reduced copper losses Smaller conductor size Improve voltage regulation Increase system capability Less energy bill

Show More

103 views 2 answers








Last Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

Show More

119 views 1 answer







If the load of the normally excited synchronous motor is increased the power factor will?
Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Show More

150 views 1 answer







The synchronous motor which works on leading power factor and does not drive any mechanical load is called?
Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Show More

163 views 1 answer







If the field of synchronous motor is under excited, power factor will be?
Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Show More

483 views 1 answer







How can we improve power factor using synchronous motor?

Show More

78 views 0 answers








Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Show More

110 views 1 answer








Last Answer : High load factor indicates total plant capacity is utilised for most of the time.

Show More

101 views 1 answer








Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Show More

185 views 1 answer








Last Answer : For a consumer the most economical power factor is generally 0.95 lagging .

Show More

209 views 1 answer








Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Show More

115 views 1 answer














Last Answer : Load factor of a power station is generally less than unity.

Show More

107 views 1 answer








Last Answer : Load factor of a power station is defined as average load/maximum demand.

Show More

321 views 1 answer







Can a synchronous condenser improve power factor?
Last Answer : Yes, synchronous condenser can improve power factor.

Show More

90 views 1 answer







What is the maximum value of power factor?
Last Answer : 1 is the maximum value of power factor.

Show More

119 views 1 answer







The synchronous speed of an 8 pole induction motor supplied power from a 50 Hz source will be ?
Last Answer : Ns         equals        f/pair pole 50/4      - 12.5

Show More

202 views 2 answers













Explain the working principle of induction motor. 
Last Answer : Working principle of induction motor: * When the motor is excited with three-phase supply, three-phase stator winding carries three-phase currents & produces a rotating magnetic field of constant magnitude and ... , which tend to move the rotor in the same direction as the rotating magnetic field. 

Show More

588 views 1 answer







Explain the activities carried out during weekly maintenance of 3 ph. Induction motor. 
Last Answer : Activities Carried out During Weekly Maintenance of 3 ph. Induction Motor:  1) Check belt tension. In cases where this is excessive it should immediately be reduces and in the case of sleeve ... and cooled by oil mist systems its important to check the oil mist flow paths/pressure components.

Show More

163 views 1 answer







State the function of following parts in Induction motor. (i) Stator (ii) Slip rings
Last Answer : Name of part Function Stator 1) Stator frame supports the core, terminal box and protects the inner parts. 2) Stator core houses stator winding. 3) Stator winding ... ) Provides facility to connect external resistance to rotor circuit through brushes for starting and control.

Show More

221 views 1 answer







List the energy conservation technique in induction motor. 
Last Answer : Following are the list of energy conservation techniques in electrical motors: 1) Reduction in iron losses by using low loss silicon steel core material laminated to thinner dimension. 2) Using bigger length ... at light load. 13) By rewinding in induction motor 14) By motor survey

Show More

1.1k views 1 answer







With a neat sketch give the working of shaded pole induction motor.
Last Answer : Explanation: It has squirrel cage rotor and salient pole stator. The stator poles are shaded partially by short circuited conductor band to create the phase difference between the fluxes emerging from shaded ... rotating magnetic field in the air-gap and torque is exerted on the squirrel cage rotor.

Show More

265 views 2 answers







Explain with neat circuit diagrams the procedures to perform no load and blocked rotor tests on three phase induction motor.

Show More

133 views 0 answers













What will happen if the induction motor runs at synchronous speed ?
Last Answer : Since there is always slip present in rotor it cannot run at synchronous speed no current will be developed hence no torque will developed

Show More

113 views 3 answers







Define Slip of Induction Motor.
Last Answer : Slip: It is the ratio of relative speed of rotor (difference between synchronous speed and rotor speed) to the synchronous speed of rotating magnetic field.  Slip = (NS – N) / NS  where , NS = synchronous speed, N = speed of rotor

Show More

59 views 1 answer







Explain the working of a single phase capacitor start induction motor. 
Last Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Show More

398 views 2 answers







State any four advantages of three phase induction motor. 
Last Answer : Advantages of three phase induction motor https://youtu.be/27OIOCKN05U

Show More

138 views 2 answers








Last Answer : Energy conservation technique in induction motor by minimizing idle and redundant running of motor: 1) Loss of energy as the no load power drawn is approximately about 12% to 16% of rated ... to unnecessary line losses. 4) Reduction in overall system energy efficiency over period of time.

Show More

691 views 1 answer







State and explain any four factors governing selection of induction motor.
Last Answer : The factors governing the selection of Induction motor: 1) Load torque required at normal speed matches with available torque of motor. 2) Break down torque or pull out torque or maximum torque ... If selecting energy efficient motor the cost benefit analysis over the long run must be worked out.

Show More

2.8k views 1 answer







Split phase induction motor
Last Answer : Split phase induction motor : There are two windings used in split phase induction motor. It is a type of single-phase induction motor. There are two winding one is called main winding and ... motor have low starting torque it is used for small fans, blowers, centrifugal pumps, grinders etc.

Show More

230 views 1 answer







State starters used for i) 3-Ph squirrel cage induction motor (3HP) ii) D.C. motor 
Last Answer : Name the starters used for following motors : i) 3 H.P. 3-Ph squirrel cage I.M: i) DOL starter OR ii) Star-Delta Starter OR ii) Auto transformer starter OR iii) Soft start starter.  ii) D.C Shunt Motor : 1) Armature resistance starter (Three Point Starter) OR 2) Four Point Starter 

Show More

154 views 1 answer







In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.
Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

Show More

136 views 1 answer







A change of 4% in the supply voltage to an induction motor will produce a change of approximately
Last Answer : A change of 4% in the supply voltage to an induction motor will produce a change of approximately 8% in the rotor torque

Show More

467 views 1 answer







The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be
Last Answer : The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be 0.5 Ohm

Show More

165 views 1 answer







In an induction motor if the flux density is reduced to one-half, of its normal value then the torque will  (1) reduce to one-half (2) reduce to one-fourth (3) remain unchanged (4) increase four times
Last Answer : In an induction motor if the flux density is reduced.to one-half, of its normal value then the torque will reduce to one-fourth

Show More

372 views 1 answer







The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above
Last Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

Show More

235 views 1 answer







Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be
Last Answer : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be 25 N -m

Show More

422 views 1 answer







The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 
Last Answer : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 4 percent

Show More

362 views 1 answer







A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for
Last Answer : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for 4 poles

Show More

305 views 1 answer







In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these
Last Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

Show More

129 views 1 answer







What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these
Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Show More

126 views 1 answer






Show More⇦ PreviousNext ⇨