1 Answer

Answer :

Nuclear power plant is invariably used as base load plant.

Related questions

Description : Compare base load plant with peak load plant on any two points.

Last Answer : Points Base load plant Peak load plant Definition The power plant which supplies base load of load curve is known as base load plant  The power plant which supplies ... ,thermal,nuclear power station Small capacity storage hydro,pumped storage hydro,gas,diesel power station.

Description : State why nuclear power plants are used as base load plants and diesel power plants as a peak load plant. 

Last Answer : 1. Because of following points Nuclear power plant used as base load power plant:-  1. Nuclear power plants is very economical for producing bulk amount of electric power 2. Nuclear power plant is reliable ... . The plants can be put on load easily. 4. Diesel engines take less time to make OFF.

Description : Compare base load plant with peak load plant. 

Last Answer : Sr.No. Points Base load plant Peak load plant  1 Definition The power plant which supplies base load of load curve is known as base load plant The power ... power station   Small capacity storage hydro, pumped storage hydro, gas, diesel power station. 

Last Answer : Large capacity generators are invariably hydrogen cooled.

Last Answer : Peak load plant can never have 100 percent load factor.

Description : Select insulating materials for following parts : (i) Insulation between heating element and base plate of electric iron. (ii) Insulation used over copper or aluminium conductor used for making coils. (iii) Transformer bushings. (iv) Insulation between transmission line and pole.

Last Answer : Parts Insulating Materials  Insulation between heating element and base plate of electric iron. Mica Insulation used over copper or aluminium conductor used for making coils.  ... Transformer bushings Porcelain  Insulation between transmission line and pole. Porcelain

Description : How to Steal a Base

Last Answer : How to Steal a Base One of the most exciting things about baseball is stealing bases. With proper timing and good skills, you'll be able to go from one base to another without so much effort. Here ... eventually have our own way of stealing a base, but for now, you can stick to these basic steps.

Description : Define the following terms : (i) Base Station (ii) Control Channel (iii) Mobile Station (iv) Page 

Last Answer : i) Base Station: - A fixed station in a mobile radio system used for radio communication with mobile stations. Base stations are located at the center or on the edge of a coverage region ... the page throughout the service area using base stations which broadcast the page on a radio carrier.

Description :  If the base current of a BJT is 250 µA and emitter current is 15 mA, then the common base current gain will be A) 0.98 B) 0.41 C) 59 D) 55  

Last Answer :  If the base current of a BJT is 250 µA and emitter current is 15 mA, then the common base current gain will be 0.98 

Description : What are the seven base units?

Last Answer : Length, mass, time, electric current, temperature, luminous intensity and amount of substance are the seven base units.

Description : The time base signal in Cathode Ray Oscilloscope (CRO) is  (1) A square wave signal (2) A sawtooth signal (3) A triangular wave signal (4) A sinusoidal signal

Last Answer : 2 Saw tooth 

Last Answer : 1. Connected Load: It is the sum of load of all equipment's connected to supply system which are in use or not in use of each consumer. OR   The sum of connected load of all consumers ... is the maximum load which a consumer uses at a particular time period out of his total connected load. 

Description : In order to have a lower cost of electrical energy generation the load factor  (1) and the diversity factor should be low (2) should be low but the diversity factor should be high (3) should be high but the diversity factor should be low (4) and the diversity factor both should be high

Last Answer : In order to have a lower cost of electrical energy generation the load factor and the diversity factor both should be high

Last Answer : Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

Last Answer : In a load curve the highest point represents peak demand.

Last Answer : Generating capacity connected to the bus bars and ready to take load when switched on is known as spinning reserve.

Last Answer : The increased load during summer months is due to increased use of fans and air conditioners.

Last Answer : Load curve is useful in deciding the operating schedule of generating units, sizes of generating units, total installed capacity of the plant.

Last Answer : The area under a load curve gives energy consumed.

Last Answer : In two part tariff, variation in load factor will affect operating or running charges.

Last Answer : A load curve indicates average kWh (kW) energy consumption during the period.

Last Answer : High load factor indicates total plant capacity is utilised for most of the time.

Last Answer : The load factor of domestic load is usually 10 to 15%.

Last Answer : Load factor of a power station is generally less than unity.

Last Answer : Load factor of a power station is defined as average load/maximum demand.

Description : What are the criteria for selection of site for hydroelectric power plant?

Last Answer : Following Factors to be kept while site selecting for Hydro power plant:  1. It should be located where high rain fall occurs. 2. A large catchments area must be available to store water. 3. It ... 12. Cost of land should be less. 13. Skilled and unskilled man power should be available nearby.

Description : Explain the function of different parts of a typical nuclear power plant with neat sketch. 

Last Answer : Functions of each part of Nuclear power plant:-  1) Nuclear Reactor: In nuclear reactor the fuel rod of U235 is placed through which tremendous amount of heat energy is ... is mechanically coupled with steam turbine. 8) Alternator: It converts mechanical energy into electrical energy.

Description : With a neat diagram explain pumped storage hydro power plant. 

Last Answer : Diagram of pumped storage hydro power plant: Explanation: In this power plant, generator is so designed that it Converts mechanical power into electrical power and also works as a ... helps in reducing a reserve capacity of PP as it provides additional power during peak load period. 

Description : Draw a layout of a thermo-chemical based power plant. 

Last Answer : Layout of a thermo-chemical based power plant:  In this process dry biomass fuels converted to produce gas ,liquid fuels or oil by thermo chemical conversion Thermo-Chemical conversion are of following ways:- 1. Direct combustion 2. Gasification 3. Pyrolysis

Description : With a neat diagram explain solar photovoltaic power plant. 

Last Answer : Diagram of solar photovoltaic power plant :  Explanation:  Solar power plant consists of following components:  1. Photovoltaic cell panel: Its function is to convert sunrays directly into DC ... .  5. Step-up transformer: It step-up input voltage to utilization voltage e.g. 230V

Description : Draw and explain fixed dome type biogas plant. 

Last Answer : Diagram of fixed dome type biogas plant: Explanation of layout of biogas plant by the method of fermentation conversion  1. Foundation : Biomass plant consists of pit excavated to desire ... the slurry from the top of the dome with the help of stirrer which is at digester chamber.

Last Answer : Because of following advantages concentrating type collector are used in solar power plant: -  1. Temperature: Temperature obtained is high because absorber area is less and collector/reflector area ... results: As tracking system is used better results are obtain than flat type collector.

Description : List the types of turbine used in hydro power plant.  

Last Answer : Following types of turbine used in hydro power plant:  1.Pelton wheel 2.Francis Turbine 3.Kaplan Turbine 4.Propeller Turbine 

Description : The overall efficiency of Thermal Power Plant is equal to _______________ .  (A) Regenerative Cycle Efficiency (B) Renkine Cycle Efficiency (C) Carnot cycle efficiency (D) None of the above

Last Answer : The overall efficiency of Thermal Power Plant is equal to Regenerative Cycle Efficiency. 

Description : In a thermal power plant, ash is collected in

Last Answer : In a thermal power plant, ash is collected in hoppers or bunkers

Description : The rankine cycle efficiency of steam power plant is  (1) 60-80% (3) 30-45% (2) 45-80% (4) 20-30%

Last Answer : The rankine cycle efficiency of steam power plant is 30-45%

Last Answer : In a power plant if the maximum demand on the plant is equal to the plant capacity, then plant reserve capacity will be zero.

Last Answer : Hydroelectric power plant is expected to have the longest life.

Last Answer : A low utilization factor for a plant indicates that plant is used for stand by purpose.

Last Answer : Maximum demand on a power plant is the greatest of all "short time interval averaged" demand during a period.

Last Answer : Annual operating expenditure of a power plant consists of fixed charges, semi-fixed charges, running charges.

Description : What is the largest power plant in the world?

Last Answer : japam

Description : What is the most common type of power plant?

Last Answer : Hydroelectric  power  plant.

Last Answer : Most efficient plants are normally used as base load plants.

Description : Explain MCB and ELCB with connection diagram supplying single phase load. 

Last Answer : OR OR Explanation: * MCB provides short circuit protection. * MCB provides overload protection * ELCB provides earth fault protection. * MCB is in series with ... occurs, the ELCB cuts off the power within the time of 0.1 sec. automatically to protect the personnel. 

Description : Single-phase mid-point controlled rectifier with RL load

Last Answer : Single-phase mid-point controlled rectifier with RL load : The circuit configuration of single-phase midpoint controlled rectifier is shown in the figure. During positive half-cycle of ... some part of next positive half-cycle of voltage with reversed polarity can appear across load.

Description : Class A Load Commutation

Last Answer : Class A: Load Commutation: The class A or load commutation (also called self-commutation or resonant commutation) is employed in thyristor circuits supplied from DC source. The commutating components include ... biased. Thus the zero-current and reverse-bias cause the thyristor to turn-off. 

Description : Single-phase Midpoint controlled rectifier with Resistive load

Last Answer : Single-phase Midpoint controlled rectifier with Resistive load:  1) During positive half cycle of AC supply, a is positive with respect to b , this makes T1 forward biased and T2 is reverse ... voltage reverses the polarity and T2 is turned off. The operation is as shown in waveforms.