Please Log in or Register for more.


104 views

1 Answer

Answer :

If the capacitor of a single-phase motor is short-circuited the motor will not start.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Show More

223 views 1 answer








Last Answer : In case one phase of a three-phase synchronous motor is short-circuited the motor will not start.

Show More

254 views 1 answer








Last Answer : In capacitor start single-phase motors current in the starting winding leads the voltage.

Show More

101 views 1 answer







A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?
Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Show More

231 views 1 answer








Last Answer : The capacitors used in single-phase capacitor motors have no polarity marking.

Show More

133 views 1 answer








Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

Show More

73 views 1 answer








Last Answer : The power factor of a single-phase induction motor is usually lagging.

Show More

189 views 1 answer








Last Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

Show More

204 views 1 answer








Last Answer : The rotor developed by a single-phase motor at starting is zero.

Show More

89 views 1 answer








Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Show More

207 views 1 answer








Last Answer : In a two value capacitor motor, the capacitor used for running purposes is paper spaced oil filled type.

Show More

162 views 1 answer








Last Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Show More

98 views 1 answer







Why is a capacitor used in a single phase motor and not in three phase motor ?
Last Answer : In 1-phase induction motor capacitor work is generate the auxiliary winding current than excite the main winding to rotor starts rotate. After rotor start rotating about 75% of their speed than auxiliary ... emf to start the motor.so,in 3-phase induction motor is self start induction motor.

Show More

260 views 6 answers







Explain the working of a single phase capacitor start induction motor. 
Last Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Show More

394 views 2 answers







In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these
Last Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

Show More

128 views 1 answer







The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α
Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Show More

150 views 1 answer







In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor
Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Show More

95 views 1 answer








Last Answer : The starting winding of a single-phase motor is placed in stator.

Show More

115 views 1 answer








Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Show More

234 views 1 answer







The secondary of a current transformer is always short-circuited under operating conditions because it?
Last Answer : The secondary of a current transformer is always short-circuited under operating conditions because it avoids core saturation and high voltage induction.

Show More

107 views 1 answer








Last Answer : To reverse the direction of rotation of a capacitor start motor while it is running we should disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding.

Show More

131 views 1 answer








Last Answer : If the centrifugal switch of a two-value capacitor motor using two capacitors fails to open then Electrolytic capacitor will, in all probability, suffer break down.

Show More

169 views 1 answer








Last Answer : Two-value capacitor motor finds increased application as compressor motor in small home air-conditioners because it has low starting as well as running currents at relatively high power factor.

Show More

74 views 1 answer








Last Answer : In a ceiling fan employing capacitor run motor secondary winding surrounds the primary winding.

Show More

101 views 1 answer







Can we use the synchronous motor as the synchronous capacitor?
Last Answer : Yes, we can use the synchronous motor as the synchronous capacitor when the synchrnous motor is overexcited.

Show More

91 views 1 answer








Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Show More

710 views 1 answer








Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Show More

126 views 1 answer







The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?
Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Show More

116 views 1 answer








Last Answer : In a single phase motor the centrifugal switch disconnects auxiliary winding of the motor.

Show More

269 views 1 answer







A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: (1) Slip frequency (2) Supply frequency (3) Frequency corresponding to rotor speed (4) Zero
Last Answer : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: Slip frequency

Show More

2.2k views 1 answer







Single-phase mid-point controlled rectifier with RL load
Last Answer : Single-phase mid-point controlled rectifier with RL load : The circuit configuration of single-phase midpoint controlled rectifier is shown in the figure. During positive half-cycle of ... some part of next positive half-cycle of voltage with reversed polarity can appear across load.

Show More

209 views 1 answer







Single-phase Midpoint controlled rectifier with Resistive load
Last Answer : Single-phase Midpoint controlled rectifier with Resistive load:  1) During positive half cycle of AC supply, a is positive with respect to b , this makes T1 forward biased and T2 is reverse ... voltage reverses the polarity and T2 is turned off. The operation is as shown in waveforms.

Show More

612 views 1 answer







When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is
Last Answer : When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is √3/2

Show More

1.4k views 1 answer







An additional condition for parallel operation of three-phase transformers over single-phase transformers is that
Last Answer : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that the transformers should belong to the same vector group

Show More

144 views 1 answer







A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V
Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Show More

182 views 1 answer







In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses
Last Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Show More

177 views 1 answer







The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero
Last Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Show More

478 views 1 answer







A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V
Last Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V

Show More

139 views 1 answer







In a single-phase transformer, the magnetizing current is (A) in phase with the no-load current (B) in quadrature with the no-load current (C) the product of no-load current and power factor (D) in phase with the flux in the core
Last Answer : In a single-phase transformer, the magnetizing current is in phase with the flux in the core

Show More

86 views 1 answer







The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be?
Last Answer : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be 4.

Show More

143 views 1 answer








Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Show More

72 views 1 answer








Last Answer : Direction of rotation of a split phase motor can be reversed by reversing the connection of either running winding or starting winding.

Show More

357 views 1 answer








Last Answer : In a split phase motor the starting winding is connected through a centrifugal switch.

Show More

117 views 1 answer








Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Show More

99 views 1 answer








Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Show More

257 views 1 answer







Obtain the Ripple factor of a full wave rectifier with shunt capacitor filter.

Show More

9 views 0 answers







Describe the operation of shunt capacitor filter with the help of circuit diagram and waveforms.

Show More

46 views 0 answers







Describe the operation of shunt capacitor filter with the help of circuit diagram and waveforms.

Show More

5 views 0 answers







State the applications and specification of (i) Resistor (ii) Capacitor (iii)Inductor
Last Answer : Application of resistor: 1.Resistors are used in high frequency instrument. 2.Resistor is used in power control circuit. 3.It is used in DC power supplies. 4.Resistors are used ... DC Current  3.Electromagnetic Interference (EMI)  4.Magnetic Saturation Flux Density  5.Curie Temperature 

Show More

238 views 1 answer







Charging Action of capacitor
Last Answer : Charging Action of capacitor .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Show More

97 views 2 answers






Show More⇦ PreviousNext ⇨