Please Log in or Register for more.

1 Answer

Answer :

In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Show More

710 views 1 answer







The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?
Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Show More

116 views 1 answer








Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Show More

99 views 1 answer








Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Show More

215 views 1 answer







Explain the working of a single phase capacitor start induction motor. 
Last Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Show More

394 views 2 answers








Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Show More

875 views 1 answer








Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Show More

223 views 1 answer








Last Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Show More

98 views 1 answer








Last Answer : The starting winding of a single-phase motor is placed in stator.

Show More

115 views 1 answer








Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Show More

234 views 1 answer







A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?
Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Show More

231 views 1 answer








Last Answer : To reverse the direction of rotation of a capacitor start motor while it is running we should disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding.

Show More

131 views 1 answer








Last Answer : In a two value capacitor motor, the capacitor used for running purposes is paper spaced oil filled type.

Show More

162 views 1 answer







A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Show More

331 views 1 answer








Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Show More

83 views 1 answer







List different starting methods of three phase synchronous motor. Explain any one of them.
Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

Show More

157 views 1 answer







How is a three phase cage induction motor self starting?
Last Answer : Any type of induction motor is self starting. Because the reason for torqe production require two flux displaced by some angle theta.If theta is constant with time then torqe will be constant;if ... torqe also pulsating. In induction motor this angle theta is not pulsating.so it is self starting 

Show More

158 views 1 answer








Last Answer : In capacitor start single-phase motors current in the starting winding leads the voltage.

Show More

101 views 1 answer







Why is a capacitor used in a single phase motor and not in three phase motor ?
Last Answer : In 1-phase induction motor capacitor work is generate the auxiliary winding current than excite the main winding to rotor starts rotate. After rotor start rotating about 75% of their speed than auxiliary ... emf to start the motor.so,in 3-phase induction motor is self start induction motor.

Show More

260 views 6 answers








Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Show More

72 views 1 answer














Last Answer : The rotor developed by a single-phase motor at starting is zero.

Show More

89 views 1 answer








Last Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

Show More

104 views 1 answer








Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Show More

145 views 1 answer








Last Answer : The repulsion-start induction-run motor is used because of high starting torque.

Show More

89 views 1 answer








Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

Show More

197 views 1 answer














Last Answer : Capacitor start motor has high torque in starting

Show More

133 views 1 answer








Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Show More

126 views 1 answer








Last Answer : Direction of rotation of a split phase motor can be reversed by reversing the connection of either running winding or starting winding.

Show More

357 views 1 answer








Last Answer : In a single phase motor the centrifugal switch disconnects auxiliary winding of the motor.

Show More

269 views 1 answer








Last Answer : In a split phase motor the starting winding is connected through a centrifugal switch.

Show More

117 views 1 answer







What is the difference between a soft start and a VFD?

Show More

76 views 0 answers







Damper winding in a synchronous motor
Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Show More

87 views 1 answer








Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Show More

222 views 1 answer








Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Show More

110 views 1 answer








Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Show More

257 views 1 answer







The damping winding in synchronous motor is generally used to?
Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Show More

157 views 1 answer







In synchronous motor, does the winding losses vary with load?
Last Answer : No, in the synchronous motor the winding losses do not vary with load.

Show More

512 views 1 answer







In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.
Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

Show More

136 views 1 answer








Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Show More

164 views 1 answer








Last Answer : The starting resistance of a D.C. motor is generally low.

Show More

169 views 1 answer








Last Answer : For starting a D.C. motor a starter is required because it limits the starting current to a safe value.

Show More

123 views 1 answer







A synchronous motor can be made self starting by providing?
Last Answer : A synchronous motor can be made self-starting by providing damper bar.

Show More

131 views 1 answer







Is induction motor is self starting?
Last Answer : Single phase induction motor is not self starting. Three phase induction motor is self starting.

Show More

111 views 1 answer







Why a dc series motor has a high starting torque?
Last Answer : motor

Show More

86 views 1 answer







Why starter is required for starting an induction motor?

Show More

114 views 0 answers







Why does induction motor have high starting current?
Last Answer : In induction motor , the flux produce is quadrature to the applied voltage. Since when we are going to start motor , there is no flux present inside . So in order to lets say compensate it ... times of current to further increase flux. So that is reason for high starting current in induction motor

Show More

143 views 2 answers







Why synchronous motor Cannot start itself?

Show More

75 views 0 answers







Which type of starter is used to start the DC motor?

Show More

77 views 0 answers






Show More⇦ PreviousNext ⇨