91 views

1 Answer

Answer :

The rotor developed by a single-phase motor at starting is zero.

Like 0 like

Please log in or register to answer this question.

Related questions

126 views

Last Answer : The starting winding of a single-phase motor is placed in stator.

1 answer
240 views

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

1 answer
215 views

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

1 answer
76 views

Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

1 answer
218 views

Last Answer : The power factor of a single-phase induction motor is usually lagging.

1 answer
232 views

Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

1 answer
219 views

Last Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

1 answer
106 views

Last Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

1 answer
655 views

Last Answer : Torque developed by a D.C. motor depends upon magnetic field, active length of the conductor, current flow through the conductors, number of conductors, radius of armature.

1 answer
96 views

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

1 answer
102 views

Last Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

1 answer
891 views

Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

1 answer
180 views

Description : Explain with neat circuit diagrams the procedures to perform no load and blocked rotor tests on three phase induction motor.

0 answers
599 views

Description : Ratio of the rotor reactance X to the rotor resistance R for a two-phase servo motor (A) is equal to that of a normal induction motor (B) is less than that of a normal induction motor (C) ... than that of a normal induction motor (D) may be less or greater than that of a normal induction motor

Last Answer : C

2 answers
217 views

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

1 answer
142 views

Last Answer : Capacitor start motor has high torque in starting

1 answer
171 views

Description : The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be

Last Answer : The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be 0.5 Ohm

1 answer
87 views

Last Answer : Locked rotor current of a shaded pole motor is slightly more than full load current.

1 answer
61 views

Last Answer : The rotor of a hysteresis motor is made of chrome steel.

1 answer
76 views

Last Answer : In a hysteresis motor, the rotor must have retentivity.

1 answer
188 views

Description : An electric motor in which both stator field and rotor rotates with same speed is called?

Last Answer : An electric motor in which both stator field and rotor rotates with same speed is called synchronous motor.

1 answer
135 views

Description : What is the rotor of a motor?

Last Answer : Rotor is the rotating or moving part in motor and generator.

1 answer
171 views

Description : List different starting methods of three phase synchronous motor. Explain any one of them.

Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

1 answer
165 views

Description : How is a three phase cage induction motor self starting?

Last Answer : Any type of induction motor is self starting. Because the reason for torqe production require two flux displaced by some angle theta.If theta is constant with time then torqe will be constant;if ... torqe also pulsating. In induction motor this angle theta is not pulsating.so it is self starting 

1 answer
139 views

Description : In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these

Last Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

1 answer
158 views

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

1 answer
139 views

Description : In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.

Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

1 answer
166 views

Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

1 answer
169 views

Last Answer : The starting resistance of a D.C. motor is generally low.

1 answer
128 views

Last Answer : For starting a D.C. motor a starter is required because it limits the starting current to a safe value.

1 answer
132 views

Description : A synchronous motor can be made self starting by providing?

Last Answer : A synchronous motor can be made self-starting by providing damper bar.

1 answer
115 views

Description : Is induction motor is self starting?

Last Answer : Single phase induction motor is not self starting. Three phase induction motor is self starting.

1 answer
86 views

Description : Why a dc series motor has a high starting torque?

Last Answer : motor

1 answer
114 views

Description : Why starter is required for starting an induction motor?

0 answers
145 views

Description : Why does induction motor have high starting current?

Last Answer : In induction motor , the flux produce is quadrature to the applied voltage. Since when we are going to start motor , there is no flux present inside . So in order to lets say compensate it ... times of current to further increase flux. So that is reason for high starting current in induction motor

2 answers
308 views

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

1 answer
105 views

Last Answer : In capacitor start single-phase motors current in the starting winding leads the voltage.

1 answer
305 views

Description : In dc machines, the armature windings are placed on the rotor because of the necessity for  (1) electromechanical energy conversion (2) generation of voltage (3) commutation (4) development of torque

Last Answer : 3  Commutation

2 answers
125 views

Last Answer : The bearings used to support the rotor shafts are generally ball bearings.

1 answer
101 views

Description : Salient pole rotor is use for which speed?

Last Answer : Salient pole rotor is use for low and medium speed prime movers.

1 answer
85 views

Description : Which rotor is use for high speed in turbo alternators?

Last Answer : Non-salient pole rotor is used for high speed in turbo alternators.

1 answer
130 views

Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

1 answer
244 views

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

1 answer
117 views

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

1 answer
278 views

Last Answer : In a single phase motor the centrifugal switch disconnects auxiliary winding of the motor.

1 answer
224 views

Description : Single-phase mid-point controlled rectifier with RL load

Last Answer : Single-phase mid-point controlled rectifier with RL load : The circuit configuration of single-phase midpoint controlled rectifier is shown in the figure. During positive half-cycle of ... some part of next positive half-cycle of voltage with reversed polarity can appear across load.

1 answer
653 views

Description : Single-phase Midpoint controlled rectifier with Resistive load

Last Answer : Single-phase Midpoint controlled rectifier with Resistive load:  1) During positive half cycle of AC supply, a is positive with respect to b , this makes T1 forward biased and T2 is reverse ... voltage reverses the polarity and T2 is turned off. The operation is as shown in waveforms.

1 answer
1.4k views

Description : When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is

Last Answer : When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is √3/2

1 answer
158 views

Description : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that

Last Answer : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that the transformers should belong to the same vector group

1 answer
191 views

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

1 answer
...