Please Log in or Register for more.


90 views

1 Answer

Answer :

The rotor developed by a single-phase motor at starting is zero.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : The starting winding of a single-phase motor is placed in stator.

Show More

115 views 1 answer








Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Show More

235 views 1 answer








Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Show More

208 views 1 answer








Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

Show More

73 views 1 answer








Last Answer : The power factor of a single-phase induction motor is usually lagging.

Show More

191 views 1 answer








Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Show More

223 views 1 answer








Last Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

Show More

205 views 1 answer








Last Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

Show More

104 views 1 answer








Last Answer : Torque developed by a D.C. motor depends upon magnetic field, active length of the conductor, current flow through the conductors, number of conductors, radius of armature.

Show More

638 views 1 answer







In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor
Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Show More

95 views 1 answer








Last Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Show More

98 views 1 answer








Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Show More

879 views 1 answer







Explain with neat circuit diagrams the procedures to perform no load and blocked rotor tests on three phase induction motor.

Show More

133 views 0 answers







Ratio of the rotor reactance X to the rotor resistance R for a two-phase servo motor (A) is equal to that of a normal induction motor (B) is less than that of a normal induction motor (C) ... than that of a normal induction motor (D) may be less or greater than that of a normal induction motor
Last Answer : C

Show More

582 views 2 answers








Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Show More

215 views 1 answer








Last Answer : Capacitor start motor has high torque in starting

Show More

135 views 1 answer







The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be
Last Answer : The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be 0.5 Ohm

Show More

165 views 1 answer








Last Answer : Locked rotor current of a shaded pole motor is slightly more than full load current.

Show More

85 views 1 answer








Last Answer : The rotor of a hysteresis motor is made of chrome steel.

Show More

56 views 1 answer








Last Answer : In a hysteresis motor, the rotor must have retentivity.

Show More

73 views 1 answer







An electric motor in which both stator field and rotor rotates with same speed is called?
Last Answer : An electric motor in which both stator field and rotor rotates with same speed is called synchronous motor.

Show More

177 views 1 answer







What is the rotor of a motor?
Last Answer : Rotor is the rotating or moving part in motor and generator.

Show More

133 views 1 answer







List different starting methods of three phase synchronous motor. Explain any one of them.
Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

Show More

159 views 1 answer







How is a three phase cage induction motor self starting?
Last Answer : Any type of induction motor is self starting. Because the reason for torqe production require two flux displaced by some angle theta.If theta is constant with time then torqe will be constant;if ... torqe also pulsating. In induction motor this angle theta is not pulsating.so it is self starting 

Show More

160 views 1 answer







In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these
Last Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

Show More

129 views 1 answer







The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α
Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Show More

150 views 1 answer







In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.
Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

Show More

136 views 1 answer








Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Show More

164 views 1 answer








Last Answer : The starting resistance of a D.C. motor is generally low.

Show More

169 views 1 answer








Last Answer : For starting a D.C. motor a starter is required because it limits the starting current to a safe value.

Show More

123 views 1 answer







A synchronous motor can be made self starting by providing?
Last Answer : A synchronous motor can be made self-starting by providing damper bar.

Show More

131 views 1 answer







Is induction motor is self starting?
Last Answer : Single phase induction motor is not self starting. Three phase induction motor is self starting.

Show More

111 views 1 answer







Why a dc series motor has a high starting torque?
Last Answer : motor

Show More

86 views 1 answer







Why starter is required for starting an induction motor?

Show More

114 views 0 answers







Why does induction motor have high starting current?
Last Answer : In induction motor , the flux produce is quadrature to the applied voltage. Since when we are going to start motor , there is no flux present inside . So in order to lets say compensate it ... times of current to further increase flux. So that is reason for high starting current in induction motor

Show More

143 views 2 answers







The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?
Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Show More

302 views 1 answer








Last Answer : In capacitor start single-phase motors current in the starting winding leads the voltage.

Show More

101 views 1 answer







In dc machines, the armature windings are placed on the rotor because of the necessity for  (1) electromechanical energy conversion (2) generation of voltage (3) commutation (4) development of torque
Last Answer : 3  Commutation

Show More

292 views 2 answers








Last Answer : The bearings used to support the rotor shafts are generally ball bearings.

Show More

122 views 1 answer







Salient pole rotor is use for which speed?
Last Answer : Salient pole rotor is use for low and medium speed prime movers.

Show More

100 views 1 answer







Which rotor is use for high speed in turbo alternators?
Last Answer : Non-salient pole rotor is used for high speed in turbo alternators.

Show More

81 views 1 answer








Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Show More

127 views 1 answer







A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?
Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Show More

232 views 1 answer







The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?
Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Show More

116 views 1 answer








Last Answer : In a single phase motor the centrifugal switch disconnects auxiliary winding of the motor.

Show More

269 views 1 answer







Single-phase mid-point controlled rectifier with RL load
Last Answer : Single-phase mid-point controlled rectifier with RL load : The circuit configuration of single-phase midpoint controlled rectifier is shown in the figure. During positive half-cycle of ... some part of next positive half-cycle of voltage with reversed polarity can appear across load.

Show More

210 views 1 answer







Single-phase Midpoint controlled rectifier with Resistive load
Last Answer : Single-phase Midpoint controlled rectifier with Resistive load:  1) During positive half cycle of AC supply, a is positive with respect to b , this makes T1 forward biased and T2 is reverse ... voltage reverses the polarity and T2 is turned off. The operation is as shown in waveforms.

Show More

615 views 1 answer







When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is
Last Answer : When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is √3/2

Show More

1.4k views 1 answer







An additional condition for parallel operation of three-phase transformers over single-phase transformers is that
Last Answer : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that the transformers should belong to the same vector group

Show More

144 views 1 answer







A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V
Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Show More

183 views 1 answer






Show More⇦ PreviousNext ⇨