220 views

1 Answer

Answer :

The power factor of a single-phase induction motor is usually lagging.

Like 0 like

Please log in or register to answer this question.

Related questions

76 views

Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

1 answer
178 views

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

1 answer
94 views

Last Answer : An induction motor has relatively high power factor at near full load.

1 answer
154 views

Description : At which time power factor of the induction motor is low?

Last Answer : The power factor of the inducction motor is low at the time of starting as compare to while the induction motor is running.

1 answer
139 views

Description : In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these

Last Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

1 answer
98 views

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

1 answer
240 views

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

1 answer
297 views

Description : Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Last Answer : Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

1 answer
121 views

Last Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

1 answer
131 views

Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

1 answer
133 views

Last Answer : In a shaded pole motor, the shading coil usually consist of a single turn of heavy copper wire which is short-circuited and carries only induced current.

1 answer
234 views

Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

1 answer
221 views

Last Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

1 answer
91 views

Last Answer : The rotor developed by a single-phase motor at starting is zero.

1 answer
106 views

Last Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

1 answer
244 views

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

1 answer
3.6k views

Description : Explain energy conservation technique “by improving power quality” for induction motor.

Last Answer : Energy conservation method in induction motor by improving power quality: Electrical energy can be conserved by improving the power quality. It can be achieved by avoiding voltage unbalance, maintaining ... losses can be minimized by using harmonic filter thus reducing the harmonics in the system.

2 answers
149 views

Description : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be?

Last Answer : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be 4.

1 answer
158 views

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

1 answer
178 views

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

1 answer
508 views

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

1 answer
80 views

Description : How can we improve power factor using synchronous motor?

0 answers
113 views

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

1 answer
94 views

Last Answer : The repulsion-start induction-run motor is used because of high starting torque.

1 answer
165 views

Last Answer : In a A.C. series motor armature coils are usually connected to commutator through resistance.

1 answer
77 views

Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

1 answer
158 views

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

1 answer
127 views

Last Answer : The starting winding of a single-phase motor is placed in stator.

1 answer
454 views

Description : Explain the working of a single phase capacitor start induction motor. 

Last Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

2 answers
138 views

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

1 answer
173 views

Last Answer : If a single phase induction motor runs slower than normal, the most likely defect is worn bearings.

1 answer
128 views

Description : How does a single phase induction motor work?

Last Answer : As we know that single phase induction is not self started because for self started we require atleast two revolving field but single phase induction motor has only one. So we provide extra ... 1phase IM classified as split phase IM, capacitor start capacitor run, capacitor start induction run.

1 answer
196 views

Description : explain the working of single phase induction motor.

Last Answer : Stator has two winding namely main winding and auxiliary winding.when single phase ac supply is given to the motor,its produces alternating field.this field cut by a cage rotor.so some emf ... due to this emf,rotor flux produced.the interaction between two fluxes produce torque.so rotor rotates.

1 answer
142 views

Last Answer : Capacitor start motor has high torque in starting

1 answer
542 views

Description : Single Phase Induction Motor

Last Answer : Single Phase Induction Motor Single phase induction motor is mostly used in home, office, shop and many single phase appliances like pumps,  ... torque and silent operation. It is uses where silent operation is required.

1 answer
149 views

Last Answer : The rotor slots, in an induction motor, are usually not quite parallel to the shaft because it helps in reducing the tendency of the rotor teeth to remain under the stator teeth.

1 answer
180 views

Description : Explain with neat circuit diagrams the procedures to perform no load and blocked rotor tests on three phase induction motor.

0 answers
416 views

Description : Explain the need and steps to conduct the reduced voltage running up test on the three phase induction motor.

0 answers
146 views

Description : State any four advantages of three phase induction motor. 

Last Answer : Advantages of three phase induction motor https://youtu.be/27OIOCKN05U

2 answers
245 views

Description : Split phase induction motor

Last Answer : Split phase induction motor : There are two windings used in split phase induction motor. It is a type of single-phase induction motor. There are two winding one is called main winding and ... motor have low starting torque it is used for small fans, blowers, centrifugal pumps, grinders etc.

1 answer
264 views

Description : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above

Last Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

1 answer
453 views

Description : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be

Last Answer : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be 25 N -m

1 answer
378 views

Description : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 

Last Answer : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 4 percent

1 answer
326 views

Description : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for

Last Answer : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for 4 poles

1 answer
111 views

Description : In a split-phase induction motor, the resistance/reactance ratios of windings are such that (A) current in the auxiliary winding leads the current in the main winding (B) current in the ... (C) both windings develop the same starting torque (D) both windings develop high starting current

Last Answer : In a split-phase induction motor, the resistance/reactance ratios of windings are such that current in the auxiliary winding leads the current in the main winding

1 answer
2.1k views

Description : A 3-phase, 4-pole, 50Hz induction motor runs at a speed of 1440 rpm. The rotating field produced by the rotor rotates at a speed of ________ rpm with respect to stator field. (A) 1500 (B) 0 (C) 1440 (D) 60

Last Answer : 0

2 answers
183 views

Description : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW

Last Answer : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is 83.33 kW

1 answer
3.1k views

Description : The torque developed by any 3-phase induction motor at 0.8 p.u. slip is (A) Full-load torque (B) unstable torque (C) starting torque (D) break down

Last Answer : The torque developed by any 3-phase induction motor at 0.8 p.u. slip is unstable torque

1 answer
...