Please Log in or Register for more.


72 views

1 Answer

Answer :

In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Show More

222 views 1 answer








Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Show More

712 views 1 answer








Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Show More

100 views 1 answer







In a split-phase induction motor, the resistance/reactance ratios of windings are such that (A) current in the auxiliary winding leads the current in the main winding (B) current in the ... (C) both windings develop the same starting torque (D) both windings develop high starting current
Last Answer : In a split-phase induction motor, the resistance/reactance ratios of windings are such that current in the auxiliary winding leads the current in the main winding

Show More

106 views 1 answer







The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?
Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Show More

116 views 1 answer








Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Show More

207 views 1 answer








Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Show More

83 views 1 answer








Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Show More

145 views 1 answer








Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Show More

879 views 1 answer








Last Answer : The starting winding of a single-phase motor is placed in stator.

Show More

115 views 1 answer








Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Show More

235 views 1 answer








Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Show More

215 views 1 answer







Damper winding in a synchronous motor
Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Show More

87 views 1 answer







A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Show More

332 views 1 answer








Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Show More

110 views 1 answer








Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Show More

258 views 1 answer







The damping winding in synchronous motor is generally used to?
Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Show More

157 views 1 answer







In synchronous motor, does the winding losses vary with load?
Last Answer : No, in the synchronous motor the winding losses do not vary with load.

Show More

512 views 1 answer







What is the purpose of auxiliary controller in substation?
Last Answer : The systems of substation auxiliaries ensure operation of substations providing internal consumers of substations with operating direct and alternating currents. Any breakdown (loss) of auxiliary systems ... whole substation, as well as serious problems during its subsequent putting into operation.

Show More

94 views 1 answer







Explain auxiliary commutation with a neat diagram. Also draw its waveform.
Last Answer : Auxiliary Commutation At start, the Ta is triggered and turned on to carry the load current. Due to the resonant circuit R-L-C, the current initially rises, attains peak and then falls to ... , the firing of auxiliary SCR commutates the main SCR, hence name is auxiliary commutation.

Show More

268 views 1 answer








Last Answer : Direction of rotation of a split phase motor can be reversed by reversing the connection of either running winding or starting winding.

Show More

358 views 1 answer








Last Answer : In a split phase motor the starting winding is connected through a centrifugal switch.

Show More

118 views 1 answer







Damper winding is provided in 3 phase synchronous motors to :
Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Show More

93 views 1 answer








Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

Show More

197 views 1 answer







The main purpose of the auxiliary winding on a split-phase, single-phase motor is to _____________. A. limit the starting voltage B. increase the starting current C. start the motor D. keep the motor running in the event the main winding should fail
Last Answer : Answer: C

Show More

2 views 1 answer







The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be?
Last Answer : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be 4.

Show More

143 views 1 answer








Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Show More

127 views 1 answer








Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

Show More

73 views 1 answer








Last Answer : The power factor of a single-phase induction motor is usually lagging.

Show More

191 views 1 answer








Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Show More

223 views 1 answer







A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?
Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Show More

232 views 1 answer








Last Answer : In a single phase motor the centrifugal switch disconnects auxiliary winding of the motor.

Show More

269 views 1 answer








Last Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

Show More

205 views 1 answer








Last Answer : The rotor developed by a single-phase motor at starting is zero.

Show More

90 views 1 answer








Last Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

Show More

104 views 1 answer







State advantages of short pitch winding over full pitch winding in alternators. 
Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Show More

478 views 1 answer








Last Answer : It is the wire wound around a aluminium metal it is found commonly in transformers or motors

Show More

106 views 1 answer







A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts
Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Show More

226 views 1 answer







A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer
Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Show More

3.4k views 1 answer







A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively
Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Show More

589 views 1 answer







Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper
Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Show More

621 views 1 answer








Last Answer : Wave winding is composed of that even number which is exact multiple of poles + 2.

Show More

90 views 1 answer








Last Answer : Lap winding is composed of any even number of conductors.

Show More

129 views 1 answer








Last Answer : In D.C. generators, lap winding is used for low voltage, high current.

Show More

94 views 1 answer








Last Answer : In the case of lap winding resultant pitch is difference of front and back pitches.

Show More

122 views 1 answer








Last Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Show More

665 views 1 answer








Last Answer : In lap winding, the number of brushes is always same as the number of poles.

Show More

324 views 1 answer








Last Answer : The resistance of armature winding depends on length of conductor, cross-sectional area of the conductor, number of conductors.

Show More

212 views 1 answer








Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Show More

355 views 1 answer








Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Show More

174 views 1 answer






Show More⇦ PreviousNext ⇨